BSEED W-SD Multi Function Power Meter

klíčová funkce

Představení produktu
The multi – functional Wlfl guide rail meter adopts a rail – type design, which is small in size, compact instructure and simple in installation; it uses an LCD display screen to display current, voltage, electricity, power,frequency and other electrical parameters, is convenient for users to acquire data and easy to operate. It hasgood anti – electromagnetic interference capabilities, meets various needs of power management, facilitates therealizationof terminal – intelligent power metering, and facilitates the retrofitting of power meters in the lateltransformation of the lighting system. It is widely used in commercial squares, science and technology parksuniversities and other occasions where billing is required, It can also be jointly deployed with energyconsumption monitoring and energy management systems. its application scope includes property bilingmanagement, electricity metering, power demand – side management, energy management andenergy-saving analysis, Other low – voltage power systems, etc.
Technické parametry
| Jmenovitý objemtage | AC 220V/110v |
| Provozní objemtage rozsah | AC 80V-300V |
| Frekvence | 50/60 Hz |
| Rozsah výkonu | 0–10 000 kWh |
| Rozsah časování | 0-999 dní |
| Účiník | 0-1.0PF |
| Teplotní rozsah | -40-150 °C |
| Přepětítage rozsah nastavení | 130-300V |
| Podpětítage rozsah nastavení | 75-21ov |
| Overcurrent setting range | 1-63A |
| Overpower setting range | 1-15kW |
| Jmenovitá izolace objtage | 400V |
| Výstupní kontakty | 1 NE |
| Mechanická životnost | 10,000krát |
| Třída ochrany | lp30 |
| Nadmořská výška | ::,2000m |
| Vlhkost | 550%at40°C(non-condensing) |
Function Introduction, Default Settings
| Možnosti | Rozsah nastavení | Výchozí parametry |
| Přepětítage
ochrana |
230-300V | 270V |
| Podpětítage
ochrana |
110-21ov | 170V |
| Nadproud
ochrana |
0.1-63A | 40A |
| Ochrana proti přetížení | 1-15kW | 8. 8KW |
| Elektrická energie
ochrana |
0–10 000 kWh | 99999kwh |
| Přes teplotu
ochrana |
0-150°( | 85 °C |
| Number of closures | 1-30krát | 5krát |
| Closingtime | 1-600 sekund | 30 sekund |
| Electricityclearing | Zapnuto/Vypnuto | vypnuto |
| Timing clearing | Zapnuto/Vypnuto | vypnuto |
| Power-up operation | Close/open/hold | zachovat |
| Přepětítagedelay
ochrana |
1-600 sec/off | vypnuto |
| Podpětítagedelay
ochrana |
1-600 sec/off | vypnuto |
| Overcurrent delay
ochrana |
1-600 sec/off | vypnuto |
| Overloaddelay
ochrana |
1-600 sec/off | vypnuto |
| Přes teplotu
delayprotection |
1-600 sec/off | vypnuto |
structural analysis

ROZMĚRY
Velikost produktu

Schéma zapojení

Set function operation
Press the set key for 5 seconds to enter the settings page, give an example of the “Overvoltage Protection” setting, click the
key cursor to move to the “Overvoltage Protection” position, press the set key to select, press the
key to adjust to the required value, press the set to save after the adjustment is completed, and press the
key to select other settings. If you do not need to set it, press the
key to move the cursor to the exit position, and then press set to return to the home page. The other settings can be the same as the “Overvoltage Protection” setting method.
Set function operation
Stáhněte si aplikaci Smart Life
or Graffiti APP Smart Connection
WIFI connection or reset operation method: Long press the wifi key 5-10s wifi indicator light will flash, turn on the phone Bluetooth, then open the Smart Life APP, click “+” in the upper right corner, select “Add Device”, wait for the device to scan out the device, click on the device to select the wifi name, enter the password to wait for the device to be added successfully.
VÍCE INFORMACÍ

Dokumenty / zdroje
![]() | W-SD Multi Function Power Meter |
Reference
- Uživatelská příručkamanual.tools