HAKINAKU HD09

Uživatelská příručka k přenosnému detektoru oxidu uhelnatého HAKINAKU (HD09)

Model: HD09

1. Úvod

This manual provides essential information for the safe and effective operation of your HAKINAKU HD09 Portable Carbon Monoxide Detector. This device is designed to monitor carbon monoxide (CO) levels, temperature, and humidity in various environments. Please read this manual thoroughly before use and retain it for future reference.

HAKINAKU HD09 Portable Carbon Monoxide Detector showing CO, humidity, and temperature readings

Figure 1: HAKINAKU HD09 Portable Carbon Monoxide Detector with display showing CO, humidity, and temperature.

2. Bezpečnostní informace

WARNING: This device is intended to detect carbon monoxide gas. It is not a substitute for proper maintenance of fuel-burning appliances, including ventilation systems, nor is it a substitute for visual inspection of such appliances. Carbon monoxide is a colorless, odorless, and non-irritating gas that can be fatal.

Familiarize yourself with the symptoms of carbon monoxide poisoning:

If the alarm sounds, immediately move to fresh air and seek medical attention. Do not re-enter the area until the source of CO has been identified and corrected, and the area has been properly ventilated.

3. Konec produktuview

The HAKINAKU HD09 is a compact, multi-functional detector designed for portability and ease of use. It features a clear display and intuitive controls.

3.1 Komponenty

3.2 Prvky displeje

The HD screen displays the following information:

HAKINAKU HD09 Portable Carbon Monoxide Detector with kickstand, showing display elements and buttons

Obrázek 2: Přední strana view of the HAKINAKU HD09 showing the display and control buttons.

3.3 Ovládací tlačítka

4. Nastavení

4.1 Počáteční nabíjení

Before first use, fully charge the device using the provided USB-C cable. Connect the USB-C end to the detector's charging port and the USB-A end to a compatible power adapter (not included).

Close-up of the HAKINAKU HD09 showing the USB-C charging port on the side

Figure 3: USB-C charging port location on the side of the device.

4.2 Možnosti umístění

The HD09 offers versatile placement options:

Three images showing the HAKINAKU HD09 being used with its kickstand, wall-mounted, and hanging by its lanyard

Figure 4: Various carrying and placement options for the HAKINAKU HD09.

5. Návod k obsluze

5.1 Zapnutí/vypnutí

To power on the device, long press the middle Power Button until the screen illuminates. To power off, long press the Power Button again until the screen turns off.

5.2 Režimy a nastavení zobrazení

5.3 Monitorování v reálném čase

Once powered on, the device will immediately begin monitoring carbon monoxide levels, temperature, and humidity. Readings are updated in real-time on the HD screen.

HAKINAKU HD09 display showing real-time CO, humidity, and temperature readings with alarm thresholds

Figure 5: Real-time detection display with CO, humidity, and temperature values.

5.4 Testování detektoru

To verify the CO detection function, expose the device to a small amount of carbon monoxide. A common method is to bring it close to a lit cigarette or burning paper that produces thick smoke. The CO concentration on the screen should increase, and the alarm should activate if levels exceed the threshold. Do not test with car exhaust or in overly airy places, as low CO concentrations may not trigger the sensor.

Video 1: Demonstration of the HAKINAKU HD09 portable carbon monoxide detector in operation, showing its display and features.

Video 2: Konecview of the HAKINAKU HD09 3-in-1 CO detector, highlighting its compact design and monitoring capabilities.

6. Informace o poplachu

The HAKINAKU HD09 features an electrochemical sensor for accurate CO detection and an 85dB alarm to alert users to dangerous levels. The alarm behavior varies based on CO concentration:

Carbon Monoxide Alarm Thresholds
CO Concentration (PPM)Indikace poplachuPotenciální nebezpečí
0-49 PPMGreen flame icon, No audible alarm.Normal level (up to 8 hours in OSHA enclosed space).
50-100 PPMYellow flame icon, 3 alerts in 3 minutes.OSHA Exposure Limits.
101-200 PPMOrange flame icon, 5 alerts in 5 minutes.Mild headache, fatigue, nausea, dizziness.
> 200 PPMRed flame icon, Continuous alarm.Dizziness, nausea, convulsions, death within 2 to 3 hours.

Upon alarm activation, follow the safety procedures outlined in Section 2.

7. Placement and Usage Scenarios

The portable design of the HD09 makes it suitable for various indoor and outdoor environments where carbon monoxide monitoring is crucial.

HAKINAKU HD09 hanging inside a tent, indicating suitability for campIng

Figure 6: The HD09 detector hanging inside a tent for camping safety.

HAKINAKU HD09 hanging in a car, indicating suitability for vehicle use

Figure 7: The HD09 detector hanging in a car for vehicle safety.

HAKINAKU HD09 on a nightstand next to a sleeping person, indicating suitability for home and hotel use

Figure 8: The HD09 detector on a nightstand, suitable for home and hotel use.

8. Údržba

8.1 Čištění

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the ventilation holes.

8.2 Péče o baterii

The device features a built-in 1000 mAh lithium-ion battery. For optimal battery life, charge the device when the battery indicator is low. The power-saved mode automatically turns off the screen after 30 seconds, extending battery life up to 72 hours, while CO monitoring continues in the background.

HAKINAKU HD09 showing battery capacity and power-saving features

Figure 9: Battery life and power-saving features of the HD09.

9. Řešení problémů

10. Specifikace

11. Záruka a podpora

For warranty information and customer support, please refer to the documentation included with your purchase or visit the official HAKINAKU webmísto. Uschovejte si doklad o koupi pro případ záručních reklamací.