Barracuda SR600

Uživatelská příručka Barracuda No Break SR600 600VA/240W

Model: SR600

1. Úvod

The Barracuda No Break SR600 is an Uninterruptible Power Supply (UPS) and voltage regulator designed to protect your electronic devices from power outages, přepětí a svtage fluctuations. With a capacity of 600VA/240W, it provides reliable backup power and stable voltage for computers, monitors, gaming consoles, routers, and other sensitive equipment. This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your SR600 unit.

Barracuda SR600 No Break unit, angled view

Figure 1: Barracuda SR600 No Break Unit

This image shows the Barracuda SR600 No Break unit from an angled perspective, highlighting its compact design and front panel.

2. Bezpečnostní informace

Please read and follow all safety instructions carefully to prevent injury or damage to the unit and connected equipment.

  • Neotevírejte UPS casing. Uvnitř nejsou žádné součásti, které by mohl uživatel opravit.
  • Do not expose the UPS to rain, moisture, or excessive humidity.
  • Ensure the UPS is placed in a well-ventilated area, away from direct sunlight or heat sources.
  • Připojujte UPS pouze k uzemněné zásuvce střídavého proudu.
  • Do not connect non-computer related equipment (e.g., medical equipment, life support systems) to the UPS.
  • In case of fire, use a dry chemical extinguisher. Water may cause electrical shock.

3. Konec produktuview

3.1 Přední panel

Barracuda SR600 No Break front panel with LED indicators

Figure 2: Front Panel of Barracuda SR600

This image displays a close-up of the Barracuda SR600's front panel, showing the power button and LED indicators for Charging, On AC, Low Battery, On Battery, Overload, and Fault.

  • Vypínač: Press to turn the UPS on or off.
  • LED indikátory:
    • Nabíjení: Indikuje, že se baterie nabíjí.
    • On AC: Indicates the UPS is operating on utility power.
    • Slabá baterie: Indicates the battery level is low.
    • Na baterii: Indicates the UPS is operating on battery power.
    • Přetížení: Indicates the connected load exceeds the UPS capacity.
    • Chyba: Indicates a system error.

3.2 Zadní panel

Barracuda SR600 No Break rear panel with outlets and ports

Figure 3: Rear Panel of Barracuda SR600

This image shows the rear panel of the Barracuda SR600, detailing the eight power outlets (four for AVR/Backup and four for Surge Only), the circuit breaker, the USB port, and the AC input.

  • AVR/Backup Outlets (4): Provide battery backup power and surge protection. Connect critical devices like computers and monitors here.
  • Přepěťové zásuvky (4): Provide surge protection only. Connect non-critical devices like printers or scanners here.
  • Jistič: Resetovatelná ochrana proti přetížení.
  • USB port: For connecting to a computer for monitoring software (if applicable).
  • AC vstup: Připojuje UPS k elektrické zásuvce.

4. Nastavení

4.1 Vybalení

Carefully remove the UPS from its packaging. Inspect the unit for any shipping damage. Retain the original packaging for future use or return.

Barracuda SR600 No Break retail box

Figure 4: Barracuda SR600 Retail Packaging

This image displays the retail box for the Barracuda SR600, showing product information and branding.

4.2 Umístění

Place the UPS on a flat, stable surface in a clean, dry, and well-ventilated area. Avoid placing it near heat-emitting appliances or in direct sunlight. Ensure there is adequate space around the unit for proper airflow.

4.3 Připojení zařízení

  1. Plug the UPS power cord into a grounded 120VAC wall outlet.
  2. Connect your critical devices (e.g., computer, monitor) to the AVR/Backup Outlets na zadním panelu.
  3. Připojte nekritická zařízení (např. tiskárnu, skener) k Vývody pouze pro přepětí.
  4. Ensure all connected devices are turned off before plugging them into the UPS.

4.4 Počáteční nabíjení

For optimal performance, charge the UPS battery for at least 8 hours before initial use. The unit will charge automatically when connected to AC power, even if the UPS is turned off.

5. Provoz

5.1 Zapnutí/vypnutí

  • Zapnout: Press and hold the power button on the front panel for approximately 3 seconds until you hear a beep and the 'On AC' LED illuminates.
  • Vypnout: Press and hold the power button for approximately 3 seconds until you hear a beep and all LEDs turn off.

5.2 Režim AC

When the UPS is connected to utility power and the 'On AC' LED is lit, it is operating in AC mode. In this mode, the UPS provides regulated power to connected devices and charges its internal battery.

5.3 Režim baterie

Během výkonu outage nebo významný objemtage fluctuation, the UPS automatically switches to battery mode. The 'On Battery' LED will illuminate, and the unit will emit an audible alarm (beeping) to indicate it is running on battery power. The alarm will sound more frequently as the battery level becomes critically low.

5.4 LED Indicators Explanation

Refer to Section 3.1 for a detailed description of each LED indicator and its meaning during operation.

6. Údržba

6.1 Péče o baterii

  • To maximize battery life, ensure the UPS is connected to AC power at all times to keep the battery fully charged.
  • Vyhněte se častému hlubokému vybíjení baterie.
  • If the UPS is to be stored for an extended period, fully charge the battery and then disconnect it from AC power. Recharge the battery every 3 months to prevent permanent damage.

6.2 Čištění

Disconnect the UPS from AC power and all connected devices before cleaning. Use a soft, dry cloth to wipe the exterior of the unit. Do not use liquid or aerosol cleaners.

6.3 Skladování

Store the UPS in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure the battery is fully charged before storage and recharged periodically as mentioned above.

7. Řešení problémů

If you experience issues with your Barracuda SR600, refer to the table below for common problems and their solutions.

ProblémMožná příčinaŘešení
UPS se nezapne.Baterie je zcela vybitá.Connect the UPS to AC power and allow it to charge for at least 8 hours.
UPS is on but provides no power to outlets.Vypnul se jistič.Reduce the load on the UPS and press the circuit breaker button on the rear panel to reset.
UPS constantly beeps in AC mode.Stav přetížení.Disconnect non-essential equipment from the UPS. Ensure total load does not exceed 240W.
Krátká doba zálohování.Battery not fully charged or battery end-of-life.Allow the battery to charge for 8 hours. If the problem persists, the battery may need replacement (contact support).
Fault LED is lit.Interní chyba.Turn off the UPS, disconnect all devices, and unplug from AC. Wait 5 minutes, then reconnect and restart. If the fault persists, contact customer support.

8. Specifikace

Technical specifications for the Barracuda No Break SR600.

FunkceSpecifikace
Kapacita600 VA / 240 XNUMX W
Vstupní objemtage120VAC
Vstupní objemtage Dosah120VAC -30% +25%
Výstupní objemtage120VAC
svtage Regulation (typical)+- 10 %
Frekvence50Hz nebo 60Hz
Regulace kmitočtu+- 1 %
Výstupní kontakty4 Energy Backup / 4 Surge Protection
Typ baterie12V/4.5Ah
Doba nabíjeníPrůměr 5 hodin
Rozměry (D x Š x V)60 x 30 x 25 cm (přibližné rozměry balení)
Hmotnost6 kg (přibližná hmotnost balení)
MateriálKov

9. Záruka a podpora

The Barracuda No Break SR600 comes with a 2letá celková záruka od data nákupu, která se vztahuje na výrobní vady a poruchy při běžném používání. Uschovejte si prosím doklad o koupi pro případné reklamace.

For technical support, warranty service, or inquiries, please contact Barracuda customer service. Refer to the product packaging or the Barracuda official webstránky s nejaktuálnějšími kontaktními informacemi.

Související dokumenty - SR600

Předview Barracuda Outlook Add-In Deployment Guide: Installation and Configuration
A comprehensive guide for deploying the Barracuda Outlook Add-In with the Barracuda Email Security Gateway. Learn installation, GPO configuration, troubleshooting, and integration steps for various Outlook versions.
Předview Barracuda Message Archiver Microsoft 365 Journaling Configuration Guide
This guide provides step-by-step instructions for configuring Microsoft 365 journaling with the Barracuda Message Archiver, ensuring compliance and efficient mail archiving.
Předview Instalační průvodce pro svítidlo Barracuda Select 3CCT LED
Komplexní instalační průvodce pro nekorozivní LED svítidlo Barracuda Select 3CCT, který zahrnuje nastavení, funkce a specifikace.
Předview Instalační příručka klienta Barracuda Network Access/VPN pro Windows
Tato příručka podrobně popisuje instalaci klienta Barracuda Network Access/VPN pro Windows a zahrnuje kompletní, pouze VPN a bezobslužné vzdálené nastavení. Naučte se, jak zabezpečit síť a navázat VPN připojení s integrovanou podporou zásad Barracuda.
Předview Firewall Barracuda CloudGen: Průvodce konfigurací VPN klient-site IKEv1 IPsec s PSK
Komplexní průvodce konfigurací VPN klient-site IKEv1 IPsec s předsdíleným klíčem (PSK) na firewallu Barracuda CloudGen. Podrobně popisuje kroky pro nastavení posluchačů služeb VPN, klientských sítí, skupinových zásad a nastavení šifrování/hashování pro zabezpečený vzdálený přístup.
Předview Firewall Barracuda CloudGen: Konfigurace adaptivní ochrany šířky pásma pro VPN tunely s SD-WAN
Komplexní průvodce konfigurací adaptivní ochrany šířky pásma pro VPN tunely na firewallech Barracuda CloudGen s využitím funkcí SD-WAN pro optimalizované tvarování provozu a správu kvality spojení. Naučte se dynamicky upravovat šířku pásma na základě metrik v reálném čase.