1. Úvod
This manual provides detailed instructions for the installation, operation, and maintenance of your OREiN 4500LM/30W Motion Sensor Outdoor Flood Light. Please read this manual thoroughly before installation and use to ensure proper function and safety. Keep this manual for future reference.

Image 1: OREiN 4500LM/30W Motion Sensor Outdoor Flood Light, front view with three adjustable light heads and a motion sensor below.
2. Bezpečnostní informace
VAROVÁNÍ: Risk of electric shock. Disconnect power at the fuse or circuit breaker before installation or servicing. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
- Před zahájením instalace se ujistěte, že je vypnuto napájení.
- Use only approved connectors and wiring suitable for outdoor use.
- Nepokoušejte se svítidlo upravovat. Jakékoli úpravy mohou vést ke ztrátě záruky a ohrožení bezpečnosti.
- Pokud si nejste jisti některou částí instalace, poraďte se s kvalifikovaným elektrikářem.
- This fixture is designed for outdoor use and is IP65 waterproof rated.
3. Obsah balení
Před zahájením instalace ověřte, zda jsou všechny komponenty přítomny:
- Svítidlo (1)
- Montážní držák (1)
- Šrouby (pro montáž)
- Drátěné matice (pro elektrické připojení)
- Návod k použití (1)
4. Vlastnosti produktu
- High Brightness & Efficiency: 4500 Lumens output with 30W power consumption, offering 150LM/W efficiency.
- Nastavitelný snímač pohybu: 180° wide sensing angle with a detection range up to 50 feet.
- Tři provozní režimy: TEST Mode, AUTO Mode, and Dusk-to-Dawn (D2D) Mode for versatile lighting control.
- Odolné a odolné vůči povětrnostním vlivům: IP65 waterproof rating, constructed from polycarbonate material for resistance against rain, dust, snow, and extreme temperatures.
- Flexibilní instalace: Supports both wall mounting and soffit mounting.
- Nastavitelné světelné hlavy: Three light heads can be independently adjusted to direct illumination where needed.
- Teplota barev: 5000 Kelvin (white light).

Image 2: Illustration demonstrating the IP65 waterproof rating, showing the flood light enduring rain, snow, and wind.

Image 3: Diagram showing the flexible adjustment angles of the three light heads (up to 340° horizontally, 90° vertically) and the motion sensor (up to 270° horizontally, 120° vertically).
5. Nastavení a instalace
This flood light is hardwired and requires connection to your home's electrical system. Professional installation is recommended.
- Vypnout napájení: Před zahájením se ujistěte, že je napájení v místě instalace vypnuto jističem.
- Bezpečná montážní konzola: Připevněte montážní držák k rozvodné krabici pomocí dodaných šroubů. Ujistěte se, že je bezpečně upevněn.
- Připojit dráty: Connect the household wiring to the light fixture's wires using the provided wire nuts. Typically, black to black (live), white to white (neutral), and green/bare copper to green (ground).
- Zajistěte svítidlo: Mount the light fixture onto the mounting bracket, ensuring a tight and secure fit.
- Insert Waterproof Plug: Ensure any necessary waterproof plugs are properly inserted to maintain the IP65 rating.
- Nastavení světelných hlav: Position the three light heads to cover the desired illumination area.

Image 4: Step-by-step diagram illustrating the hardwired installation process, including securing the mounting bracket, connecting wires, and attaching the light fixture.

Obrázek 5: Příkladamples of the flood light installed in both wall-mounted and soffit-mounted configurations.
6. Návod k obsluze
The OREiN flood light features an adjustable motion sensor with three distinct operating modes:

Obrázek 6: Detail view of the motion sensor controls, showing dials for TIME (1/5/10 minutes), SENSITIVITY (10ft/20ft/30ft/Max 50ft), and a switch for MODE (TEST/AUTO/D2D).
Výběr režimu:
- TESTOVACÍ režim: The light turns on for a fixed 5-second duration when motion is detected, regardless of ambient light. This mode is used for testing the sensor's coverage area during installation.
- AUTO režim: The light activates only at night when motion is detected. The duration the light stays on and the sensitivity of the sensor can be adjusted.
- D2D (Dusk-to-Dawn) Mode: The light automatically turns on at dusk and turns off at dawn, providing continuous illumination throughout the night. Motion sensing is not active in this mode.

Image 7: Visual explanation of the three operating modes: Test Mode (light on for 5s with motion), D2D Mode (light on all night), and Auto Mode (light on at night with motion for adjustable time).
Adjusting Settings (AUTO Mode):
- TIME Dial: Adjusts how long the light stays on after motion is detected. Options typically include 1, 5, or 10 minutes.
- SENSITIVITY Dial: Adjusts the detection range of the motion sensor. Options typically include 10ft, 20ft, 30ft, or Max (up to 50ft). A higher sensitivity setting means a longer detection distance.
7. Údržba
Pravidelná údržba zajistí optimální výkon a dlouhou životnost vašeho světlometu.
- Čištění: Pravidelně čistěte svítidlo a čočku pohybového senzoru měkkým hadříkem.amp tkanina. Nepoužívejte abrazivní čisticí prostředky nebo rozpouštědla.
- Inspekce: Regularly inspect the wiring and mounting for any signs of wear, damage, or loosening. Address any issues promptly.
- Bez výměny žárovky: This LED fixture does not require bulb replacement. The integrated LEDs are designed for long-term use.
8. Řešení problémů
If you encounter issues with your OREiN flood light, refer to the following common problems and solutions:
- Světlo se nerozsvítí:
- Ensure power is supplied to the fixture and the circuit breaker is not tripped.
- Check the mode setting. In AUTO mode, it will only activate at night. In D2D mode, it will only activate at dusk.
- Zkontrolujte, zda není senzor pohybu zakrytý.
- Světlo svítí nepřetržitě:
- If in D2D mode, this is normal operation.
- If in AUTO mode, reduce the SENSITIVITY setting. Environmental factors like moving branches or passing vehicles can trigger the sensor.
- Ensure the TIME dial is set correctly.
- Pohybový senzor nedetekuje:
- Increase the SENSITIVITY setting.
- Ujistěte se, že je čočka senzoru čistá a ničím nerušená.
- Verify the sensor is aimed correctly towards the desired detection area.
9. Specifikace
| Funkce | Specifikace |
|---|---|
| Značka | OREiN |
| Název modelu | OL3600354 |
| Rozměry produktu | 7.6 cm D x 8 cm Š x 6 cm V |
| Hmotnost položky | 1.92 libry |
| Jas | 4500 XNUMX lumenů |
| Wattage | 30 wattů |
| Teplota barev | 5000 Kelvinů (bílé světlo) |
| Úroveň odolnosti proti vodě | IP65 Vodotěsný |
| Motion Sensing Angle | 180° |
| Vzdálenost snímání pohybu | Až 50 stop |
| Zdroj napájení | AC/DC (Hardwired) |
| Materiál | Akrylonitrilbutadienstyren (ABS) |
| Typ instalace | Montáž na stěnu a na strop |
| svtage | 120 voltů |
| Zahrnuté komponenty | Light Fixture, Mounting Bracket, Screws, Wire Nuts, Instruction Manual |

Image 8: Comparison table showing specifications for different OREiN 3-head flood light models, including the 4500LM/30W version.
10. Záruka
This OREiN flood light is covered by a Záruka 24 měsíců od data nákupu. Uschovejte si doklad o koupi pro případ reklamace. Záruka se vztahuje na vady materiálu a zpracování při běžném používání.
11. Podpora
For any questions, technical assistance, or warranty inquiries, please contact OREiN customer support:
- Telefonická podpora: 1-844-506-1530 (available during working hours)
- Online nápověda: 7 days a week, 24 hours a day. Please refer to the official OREiN website or contact through the Amazon platform for online support options.