1. Úvod
Thank you for choosing the Rebel POWER-1000 Pure Sine Wave UPS Inverter. This device is designed to provide stable and safe emergency power for various applications, including central heating furnaces, heat pumps, refrigerators, and other RTV/AGD systems. It features a pure sine wave output, ensuring compatibility with sensitive electronic and inductive loads, and offers three operating modes: emergency power supply (UPS), rectifier (charger), and inverter.
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your POWER-1000 inverter. Please read it thoroughly before use and retain it for future reference.
2. Bezpečnostní pokyny
Vždy dodržujte následující bezpečnostní opatření, abyste předešli zranění nebo poškození zařízení:
- Elektrická bezpečnost: Ensure the device is connected to a properly grounded power outlet. Do not open the casing; uvnitř nejsou žádné součásti, které by mohl uživatel opravit. Veškerý servis svěřte kvalifikovanému personálu.
- Připojení baterie: Connect the battery with correct polarity (red to positive, black to negative). Incorrect connection can cause severe damage to the inverter and battery. Use a 12V DC battery with a capacity between 50-200 Ah (55 Ah suggested).
- Větrání: Ensure adequate ventilation around the unit. Do not block the fan or ventilation openings. Overheating can lead to device malfunction or damage.
- Prostředí: Operate the device within the specified temperature range of 0 - 40°C and humidity of 10 - 90%. Avoid direct sunlight, moisture, dust, and corrosive environments.
- Ochrana proti přetížení: Do not exceed the rated power of 700 W. The device is equipped with overload protection, but continuous overloading can shorten its lifespan.
- Kontakt s kapalinou: Keep the device away from liquids. In case of accidental liquid contact, immediately disconnect power and consult a service technician.
- Děti a domácí mazlíčci: Udržujte zařízení mimo dosah dětí a domácích zvířat.
3. Komponenty produktu
Familiarize yourself with the main components of your Rebel POWER-1000 UPS Inverter:

Obrázek 3.1: Přední panel
This image displays the front of the Rebel POWER-1000 inverter, featuring the LED display which shows operational status, battery charge, and load level. Below the display is the main ON/OFF switch.

Obrázek 3.2: Zadní panelview
This image shows the rear panel of the inverter. Visible components include the cooling fan, circuit breaker, two output sockets, battery connection terminals (red and black cables), and the AC input socket.
Figure 3.3: Rear Panel Connections Detail
Zavírač view of the rear panel, highlighting the 'OUTPUT' sockets for connecting appliances, the 'BATTERY +12V' terminals for external battery connection, the 'AC INPUT 230V' for mains power, and the 'CIRCUIT BREAKER' for protection.
Klíčové komponenty:
- LED displej: Provides real-time information on operating status, battery charge level, and load level.
- Main ON/OFF Switch: Controls the power to the inverter.
- AC výstupní zásuvky: Two 230V AC sockets for connecting your devices.
- Svorky baterie (12 V DC): Connect to an external 12V DC battery. Ensure correct polarity.
- Vstupní napětí (230 V): Connects the inverter to the mains power supply for charging the battery and providing power in UPS mode.
- Chladicí ventilátor: Odvádí teplo vznikající během provozu.
- Jistič: Poskytuje ochranu proti nadproudu.
4. Nastavení
Follow these steps to set up your Rebel POWER-1000 UPS Inverter:
- Rozbalení: Carefully remove the inverter from its packaging. Inspect for any signs of damage.
- Umístění: Place the inverter on a stable, flat surface in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure sufficient space around the unit for airflow.
- Připojení baterie:
- Ensure the inverter is switched OFF.
- Připojte červený kabel baterie k kladný (+) svorku vaší 12V DC baterie.
- Připojte černý kabel baterie k záporný (-) svorku vaší 12V DC baterie.
- Tighten all connections securely to prevent arcing.
- Připojení k elektrické síti: Zapojte vstupní kabel střídače do standardní zásuvky 230 V AC.
- Připojení zařízení: Plug the devices you wish to power into the 230V AC output sockets on the rear of the inverter. Ensure the total power consumption of connected devices does not exceed 700 W.
5. Návod k obsluze
The Rebel POWER-1000 operates in three main modes:
- UPS Mode (Emergency Power Supply): When connected to mains power, the inverter charges the external battery and simultaneously supplies power to connected devices. In case of a power outage, it automatically switches to battery power within <4 ms, providing uninterrupted power.
- Rectifier Mode (Battery Charger): When connected to mains power without any load, the inverter functions as a battery charger, replenishing the external battery.
- Režim invertoru: When not connected to mains power, the inverter converts 12V DC battery power into 230V AC pure sine wave power for your connected devices.
Starting the Inverter:
- Ensure all connections (battery, AC input, loads) are secure.
- Press the main ON/OFF switch on the front panel. The LED display will illuminate, indicating the current operating status, battery charge, and load level.
- The inverter will automatically select the appropriate operating mode based on the presence of mains power and connected loads.
LED Display Information:
The clear LED display provides crucial information:
- Vstupní objemtage: Zobrazuje hlasitost vstupního střídavého proudutagod sítě.
- Výstupní objemtage: Zobrazuje výstupní napětí 230 V ACtage.
- Baterie Voltage: Udává aktuální objtagpřipojené 12V baterie.
- Úroveň zatížení: Ukazuje procentatage of the inverter's capacity being used by connected devices.
- Provozní stav: Icons or indicators for mains power, battery power, charging, and fault conditions.
6. Údržba
Pravidelná údržba zajišťuje optimální výkon a dlouhou životnost vašeho střídače:
- Čištění: Periodically clean the exterior of the inverter with a soft, dry cloth. Ensure the cooling fan and ventilation openings are free from dust and debris. Do not use liquid cleaners.
- Kontrola baterie: Regularly check battery terminals for corrosion and ensure connections are tight. If using a lead-acid battery, check electrolyte levels if applicable and top up with distilled water as needed (refer to battery manufacturer's instructions).
- Větrání: Always ensure the inverter has adequate ventilation. Do not place objects on top of the unit or block its air vents.
- Skladování: If storing the inverter for an extended period, disconnect it from both mains power and the battery. Store in a cool, dry place. For optimal battery health, fully charge the battery before storage and recharge it every 3-6 months.
7. Řešení problémů
If you encounter issues with your Rebel POWER-1000, refer to the following table:
| Problém | Možná příčina | Řešení |
|---|---|---|
| Měnič se nezapne | No battery connected or battery discharged; Main switch off; Blown circuit breaker. | Connect a charged battery; Turn on the main switch; Check and reset the circuit breaker on the rear panel. |
| Žádný AC výstup | Overload; Short circuit; Battery low; Inverter fault. | Reduce connected load; Check for short circuits in connected devices; Recharge or replace battery; If problem persists, contact support. |
| Baterie se nenabíjí | Vstup střídavého proudu není připojen; hlasitost vstupu střídavého proudutage too low/high; Battery fault. | Ensure AC input cable is securely plugged in; Check mains voltage; Test battery or replace if faulty. |
| Varování před přetížením na displeji | Total power of connected devices exceeds 700 W. | Disconnect some devices to reduce the load below 700 W. |
| Jednotka je neobvykle horká | Blocked ventilation; Excessive load; High ambient temperature. | Ensure vents are clear; Reduce load; Move unit to a cooler environment. |
If the problem persists after attempting these solutions, please contact Rebel customer support or your retailer.
8. Specifikace
Technical specifications for the Rebel POWER-1000 UPS Inverter (Model RB-4003):
| Funkce | Specifikace |
|---|---|
| Jmenovitý výkon | 700 W (1000 VA) |
| Typ baterie | 12 V DC |
| Max. Objem baterietage | 15 V DC |
| Vstupní objemtage Dosah | 190 - 260 V AC |
| Vstupní frekvence | 45 - 60 Hz |
| Výstupní objemtage (AC) | 230 V AC +/-5% (Inverter: 230 V AC +/-3%) |
| Výstupní frekvence | 50/60 Hz +/-0.5 Hz |
| Výstupní průběh | Čistá sinusová vlna |
| Výstupní účinnost | >= 85% (DC to AC) |
| Nabíjecí proud baterie | Max. 10 A. |
| Doporučená kapacita baterie | 50-200 Ah (suggested: 55 Ah) |
| Odhadovaná doba nabíjení | 4-14 hours (dependent on battery capacity) |
| Čas přepínání | =<4 ms |
| Ochrany | Overload, Short Circuit, Over/Under Voltage |
| Provozní teplota | 0 - 40 °C |
| Provozní vlhkost | 10 - 90 % |
| Rozměry (D x Š x V) | 336 x 143 x 178 mm |
| Hmotnost | 4.3 kg |
9. Záruka a podpora
The Rebel POWER-1000 UPS Inverter is manufactured by Rebel. For warranty information, please refer to the warranty card included with your product or consult the retailer from whom you purchased the device. Keep your proof of purchase for warranty claims.
For technical support or service inquiries, please contact your local Rebel distributor or the point of purchase. Ensure you have your product model (RB-4003) and serial number (if applicable) ready when contacting support.