1. Úvod
The Victron Energy MultiPlus-II is a pure sine wave inverter charger that integrates the functionalities of both the MultiPlus and MultiGrid series. This unit is designed to provide reliable power conversion and battery charging for a wide range of applications, including marine, RV, off-grid, and industrial systems. It features an external current transformer option for advanced PowerControl and PowerAssist functionalities, optimizing self-consumption and ensuring stable power delivery.
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your MultiPlus-II inverter charger.
2. Klíčové vlastnosti
- Integrated Inverter and Charger: Combines a powerful pure sine wave inverter with an advanced battery charger.
- Power Assist: Prevents overload of a limited AC source (e.g., generator or shore power) by boosting the output with power from the battery.
- Uninterrupted AC Power (UPS Function): In the event of a grid failure, the inverter automatically takes over the supply to connected loads within 20 milliseconds, ensuring continuous operation.
- Parallel and Three-Phase Operation: Up to six units can operate in parallel for increased power output. Three units can be configured for three-phase output.
- Slimmer Profile: Modern manufacturing techniques result in a more compact design.
- Nízká spotřeba energie v pohotovostním režimu: Designed for energy efficiency, consuming significantly less power in standby mode.
- Snadná instalace: Features accessible AC and DC connections via a service panel.
- Dodržování: Meets UPS and solar standards, including built-in anti-islanding.
3. Konec produktuview

Obrázek 3.1: Přední strana view of the Victron Energy MultiPlus-II Inverter Charger.

Obrázek 3.2: Přesview of MultiPlus-II key features including MultiPlus/MultiGrid functions, external current transformer, PowerAssist, and remote monitoring.

Figure 3.3: Dimensions of the MultiPlus-II unit, highlighting its compact size.

Figure 3.4: Diagram illustrating the UPS function, showing how the MultiPlus-II provides uninterrupted AC power during grid outages.

Figure 3.5: The MultiPlus-II as a key component in an Energy Storage System (ESS), integrating with MPPT Solar Chargers or Grid-tie PV Inverters.
4. Instalace
The MultiPlus-II is designed for wall mounting. A wall mount plate is included to facilitate installation.
4.1 Montáž na stěnu
- Securely mount the included wall mount plate to a suitable wall surface.
- Align the hook at the back of the MultiPlus-II casing with the wall mount plate and carefully hang the unit.
- Ensure the unit is firmly seated on the plate.
4.2 Zapojení kabeláže
Before making any connections, ensure all power sources are disconnected. Always refer to the detailed wiring diagrams in the full product manual for specific instructions and safety guidelines.
- Unscrew the fasteners at the bottom of the enclosure and remove the service panel to access the connection terminals.
- Připojení baterie: Connect the battery cables to the designated terminals. Use a torque wrench with an insulated box spanner to tighten the connections to a maximum of 7 Nm to prevent short circuits.
- AC Mains and Load Connections: Connect the AC mains input and AC load outputs to their respective terminals. The MultiPlus-II features two AC outputs.
- Připojení příslušenství: Connect any optional accessories such as a Venus GX, Color Control GX, or an external current transformer as required for your system.
- Once all connections are secure, reattach the service panel and fasten the screws.
Video 4.1: An introductory video to the Victron Energy MultiPlus-II, demonstrating its features and installation steps, including wall mounting and wiring connections.
5. Provoz
5.1 Powering On/Off and Modes
The MultiPlus-II unit has a switch located at the bottom for controlling its operation modes:
- Position 'I' (On): The unit is fully operational, providing both inverter and charger functions.
- Position 'O' (Off): The unit is completely powered off.
- Position 'II' (Charger Only): The unit functions solely as a battery charger, without inverting AC power.
5.2 Monitorování a řízení
For comprehensive monitoring and control of your MultiPlus-II and the entire energy system, Victron Energy offers several accessories:
- BMV-712 Smart Battery Monitor: Poskytuje informace o stavu baterie v reálném časetage, current, power, consumed Ah, and state of charge. Features built-in Bluetooth for monitoring via the VictronConnect app.
- Venus GX / Color Control GX: These devices act as communication hubs, allowing for remote configuration and monitoring of your system when connected to the internet. Operational data can be stored and displayed on the free Victron Remote Management (VRM) webmísto.
- Aplikace VictronConnect: Connects to Bluetooth-enabled devices like the BMV-712 for instant access to system data on your smartphone or tablet.
- VRM Webmísto: A free online portal for remote monitoring, configuration, and data analysis of your Victron Energy system from anywhere in the world.

Figure 5.1: Remote configuring and monitoring setup using a GX device connected to the internet.
6. Specifikace
| Funkce | Detail |
|---|---|
| Název modelu | PMP122305102 |
| Rozměry produktu | 6 x 11 x 23 palce |
| Hmotnost položky | 55.4 libry |
| Vstupní objemtage | 12 voltů |
| Zdroj napájení | Napájení z baterie |
| Výrobce | Energie Victron |
| První k dispozici | 23. prosince 2022 |
7. Řešení problémů
This section provides general guidance for common issues. For detailed troubleshooting, please refer to the comprehensive Victron Energy MultiPlus-II manual available on the official Victron Energy webwebu nebo kontaktujte zákaznickou podporu.
7.1 Běžné problémy
- Bez střídavého výstupu: Check the input AC source, battery voltage, and the unit's operating mode (ensure it's not in 'Charger Only' mode). Verify all connections are secure.
- Baterie se nenabíjí: Confirm AC input is present and stable. Check battery connections and the charger settings. Ensure the unit is in 'On' or 'Charger Only' mode.
- Upozornění na přetížení: Reduce the connected AC load. The PowerAssist feature should help prevent overloads, but excessive loads may still trigger a warning.
- Jednotka nereaguje: Power cycle the unit by switching it off and then back on. If the issue persists, check all wiring and consult the full manual.
8. Údržba
Regular maintenance ensures the longevity and optimal performance of your MultiPlus-II inverter charger.
- Pravidelná kontrola: Pravidelně kontrolujte všechna kabelová spojení, zda nejsou pevně utažená a zda nejeví známky koroze nebo poškození.
- Čištění: Keep the unit's ventilation openings clear of dust and debris to ensure proper airflow and cooling. Use a soft, dry cloth for cleaning the exterior.
- Stav baterie: Monitor battery health regularly, especially if using lead-acid batteries. Ensure adequate ventilation during charging to prevent gas buildup.
- Aktualizace firmwaru: Check the Victron Energy website for available firmware updates to ensure your unit has the latest features and improvements.
9. Záruka a podpora
Victron Energy products are known for their quality and reliability. For warranty information, technical support, or service, please contact Victron Energy directly or an authorized dealer.
- Oficiální Webmísto: Navštivte Energie Victron webmísto for product documentation, FAQs, and support resources.
- Zákaznická podpora: Refer to your purchase documentation for specific contact details for customer support or your local dealer.