OWON O-321-80A

OWON PC321-TY 3 Phase WiFi Smart Home Energy Monitor User Manual

Zavedení

This manual provides instructions for the installation, operation, and maintenance of your OWON PC321-TY 3 Phase WiFi Smart Home Energy Monitor. This device is designed to help you monitor your home's electricity consumption in real-time, offering insights into voltage, current, and power factor.

OWON PC321-TY Energy Monitor overview with app interface
Figure 1: OWON PC321-TY Energy Monitor and SmartLife app interface showing real-time data.
Wide range of applications for the OWON PC321-TY energy monitor
Figure 2: The OWON PC321-TY is suitable for various applications including homes, markets, factories, and hotels.

Důležité bezpečnostní informace

VAROVÁNÍ: Výkon třamp must be installed and serviced only by a qualified professional. Do not touch the terminals of the device during testing. Turn off all power supply to this equipment before installation to ensure safety.

Vlastnosti produktu

Nastavení a instalace

1. Vybalení a kontrola

Verify all components are present: OWON PC321-TY main unit, three 80A current sensors (clamps), and antenna.

2. Instalace aplikace

Download and install the 'SmartLife' application on your smartphone from your device's app store. Follow the in-app instructions to create an account and add your device.

3. Current Sensor (Clamp) Instalace

Důležité: Ensure the main power supply to the circuit you are monitoring is turned OFF before proceeding.

Connect the current sensors to the main unit. Attach the current clamps to the power cables of the circuits you wish to monitor. Ensure the arrow on each clamp points towards the load (P1→P2 or K→L) for correct current flow direction.

Diagram showing the correct direction for current clamp instalace
Figure 3: Correct orientation of the current clamp, with the arrow pointing towards the load.

4. Schémata zapojení

Jednofázové zapojení

For single-phase systems, connect the main unit and clamps, jak je znázorněno na obrázku níže.

Single phase wiring diagram for OWON PC321-TY energy monitor
Figure 4: Single Phase Wiring Diagram. Ensure connections match the diagram for proper operation.

3 Phase Wiring

For three-phase systems, ensure that each current transformer (CT) for L1, L2, and L3 corresponds to the respective phase of the circuit being measured.

Three phase wiring diagram for OWON PC321-TY energy monitor
Figure 5: 3 Phase Wiring Diagram. Verify CT connections for L1, L2, L3 match the circuit phases.

5. Power On and WiFi Connection

Once all connections are secure and verified, restore power to the circuit. Follow the 'SmartLife' app instructions to connect the device to your 2.4 GHz WiFi network. An internet connection is required for real-time data monitoring.

Návod k obsluze

Monitoring Energy Data

Open the 'SmartLife' app on your smartphone. The app will display real-time energy consumption data, including total energy consumed, individual phase consumption, voltage, current, active power, and power factor. The app provides data updates every 2 seconds.

SmartLife app interface showing real-time and historical energy data
Figure 6: SmartLife App Interface displaying live and historical energy consumption data.

Historická data

The 'SmartLife' app allows you to view historical consumption records, enabling you to track energy usage over time (daily, monthly, yearly).

Údržba

The OWON PC321-TY is designed for low maintenance. Periodically check all wiring connections for security and ensure the device is free from dust and moisture. No user-serviceable parts are inside the main unit.

Odstraňování problémů

Device Not Connecting to WiFi

Nepřesná čtení

App Not Displaying Data

Physical Damage to Antenna Cable

Specifikace

FunkceSpecifikace
Číslo modeluO-321-80A
ZnačkaOWON
Styl3Phase/ 80A
Zdroj napájeníNapájení z baterie
svtage240 voltů (provozní napětítage)
Proudové senzory3 x 80A Clamp Senzory
Frekvence WiFi2.4 GHz
Přesnost dat±2 %
Rychlost aktualizace dat2 sekund
První k dispozici15. února 2023
Diagram showing the dimensions of the OWON PC321-TY energy monitor
Figure 7: Product dimensions of the OWON PC321-TY main unit and connected sensors.

Záruka a podpora

For warranty information and technical support, please refer to the OWON official webnebo se obraťte na jejich zákaznický servis. Uschovejte si doklad o koupi pro případ reklamace.

Související dokumenty - O-321-80A

Předview PC321-TY Jedno/3fázové napájení třamp Rychlý průvodce
Stručný návod k obsluze jednofázového/třífázového napájecího zdroje PC321-TYamp, s podrobným popisem bezpečné manipulace, technických specifikací, instalace, konfigurace sítě, montáže a řešení problémů.
Předview Owon PC321-Z-TY Single/3-phase Power Clamp Rychlý průvodce
Quick start guide for the Owon PC321-Z-TY Single/3-phase Power Clamp, covering safety, technical specifications, installation, and network configuration for ZigBee connectivity.
Předview PC321-TY Jedno/3fázové napájení třamp Quick Start Guide | OWON
Comprehensive quick start guide for the OWON PC321-TY Single/3-phase Power Clamp. Learn about safety, technical specifications, installation, network configuration, and troubleshooting.
Předview Víceobvodový měřič výkonu Owon PC341-W-TY – stručný návod k obsluze | Elektrické monitorování
Komplexní stručný návod k obsluze víceobvodového měřiče spotřeby Owon PC341-W-TY. Seznamte se s instalací, technickými specifikacemi, konfigurací sítě a bezpečnostním zacházením s vaším inteligentním zařízením pro monitorování spotřeby energie.
Předview Stručný návod k obsluze chytrého Wi-Fi termostatu Owon PCT523-W-TY
Stručný návod k instalaci a nastavení chytrého Wi-Fi termostatu Owon PCT523-W-TY, který zahrnuje bezpečnost, kroky instalace, schémata zapojení, nastavení aplikace a základní ovládání termostatu.
Předview OWON CMS101 Digital Oscilloscope & Multimeter Clamp Uživatelská příručka měřiče
Comprehensive user manual for the OWON CMS101 Digital Oscilloscope & Multimeter Clamp Meter, covering safety information, quick start guide, instrument panel details, multimeter and oscilloscope usage, technical specifications, and maintenance.