1. Úvod a produktview
The Prity FM E is a robust 12KW wood stove featuring an integrated oven, designed for efficient heating of residential spaces. This appliance is certified to EN standards, including CE, BlmSchV2, and ECO design, ensuring compliance with European safety and environmental regulations. It is constructed from durable steel, with a 2mm thick body and a 3-4mm thick top plate. The combustion chamber is lined with firebricks to accumulate heat and enhance burning efficiency, and is equipped with heat-resistant ceramic glass. The integrated oven includes a tempered glass pane and a thermometer for convenient cooking.
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Prity FM E wood stove with oven.
Obrázek 1: Přední strana view of the Prity FM E 12KW Wood Stove with Oven.
2. Bezpečnostní informace
Please read all safety instructions carefully before installing or operating the Prity FM E wood stove. Failure to follow these instructions can result in property damage, bodily injury, or even death.
- Typ paliva: Only use dry wood or wood briquettes with a moisture content of less than or equal to 20%. Do not burn treated wood, trash, plastics, or any other unauthorized materials, as this can produce toxic fumes and damage the stove.
- Minimální vzdálenosti od hořlavých materiálů: Maintain the following minimum distances from combustible materials to prevent fire hazards:
- Zadní: 400 mm
- Sides (Left and Right): 400 mm
- Přední: 800 mm
- Strop: 600 mm
- Větrání: Ensure adequate ventilation in the room where the stove is installed to prevent the buildup of carbon monoxide.
- Komín: The stove must be connected to a suitable, properly installed, and regularly maintained chimney system. The flue diameter required is 130 mm.
- Profesionální instalace: Installation should be performed by a qualified professional in accordance with all local and national building codes and regulations.
- Horké povrchy: The exterior surfaces of the stove become extremely hot during operation. Use appropriate protective gloves when operating the stove and keep children and pets away.
- Likvidace popela: Popel zlikvidujte v kovové nádobě s těsně přiléhajícím víkem, mimo dosah hořlavých materiálů.
- Hasicí přístroj: Keep a fire extinguisher readily available near the stove.
Image 2: CE Mark and product barcode (3800215096211) indicating compliance with European standards.
3. Nastavení a instalace
Proper installation is critical for the safe and efficient operation of your wood stove. It is highly recommended that installation be carried out by a certified professional.
3.1 Výběr místa
- The stove is designed for central placement within a room.
- Ensure the floor beneath the stove is capable of supporting its weight (99 kg) and any additional load from fuel. If necessary, install a non-combustible floor protector that extends beyond the stove's footprint according to local regulations and the specified clearances.
- Adhere strictly to the minimum clearances to combustible materials as outlined in Section 2.
3.2 Připojení ke komínu
- Connect the stove to a dedicated chimney flue with a diameter of 130 mm.
- Ensure all flue pipe connections are sealed properly to prevent smoke leakage.
- The chimney system must be clean, in good repair, and provide adequate draft (minimum 11 Pa).
3.3 Rozměry
The overall dimensions of the Prity FM E stove are 490 mm (Width) x 460 mm (Depth) x 1050 mm (Height).
Image 3: Dimensional diagram of the Prity FM E wood stove, showing height, width, and depth.
4. Návod k obsluze
4.1 Initial Firing (Curing)
The first few fires should be small and moderate to allow the paint and materials to cure. During this process, some smoke and odor may be emitted, so ensure good ventilation. Avoid high temperatures during the first 2-3 uses.
4.2 Loading Fuel
- Open the combustion chamber door carefully.
- Place dry wood or briquettes onto the cast iron grate. Do not overfill the combustion chamber.
- Close the door securely after loading.
4.3 Air Supply Control
- The přední klapka located below the combustion chamber controls the primary air supply, which is essential for ignition and maintaining a strong fire. Open it fully for starting a fire and adjust as needed.
- The smoke damper (flue damper) allows for adjustment of the flame intensity and heat output. Opening it increases draft and burning rate, while closing it reduces them. Use this to fine-tune your fire.
4.4 Používání trouby
- The integrated oven is located above the combustion chamber.
- Monitor the oven temperature using the built-in thermometer.
- Adjust the fire's intensity using the air supply controls to achieve the desired oven temperature.
- The oven door features tempered glass, allowing you to view your food without opening the door.
4.5 Odstraňování popela
Regularly remove ashes from the ash pan located below the grate. Do not allow ashes to build up and touch the bottom of the grate, as this can restrict airflow and damage the grate.
5. Údržba
Regular maintenance ensures the longevity and safe operation of your Prity FM E wood stove.
- Čištění popelníku: Empty the ash pan regularly, ideally before each use or when it is full. Ensure ashes are completely cool before disposal.
- Čištění skla: Clean the ceramic glass of the combustion chamber and the tempered glass of the oven with a specialized glass cleaner for wood stoves when the stove is cold.
- Čištění komínů: Have your chimney inspected and cleaned by a certified chimney sweep at least once a year, or more frequently depending on usage, to prevent creosote buildup and reduce the risk of chimney fires.
- Firebrick Inspection: Periodically inspect the firebricks lining the combustion chamber for cracks or damage. Replace any severely damaged bricks to maintain efficiency and protect the stove body.
- Těsnění dveří: Check the door seals for wear and tear. Worn seals can lead to air leaks, reducing efficiency. Replace them as needed.
- Sklad dřeva: The stove features an integrated compartment to store and dry wood, ensuring it is ready for use.
6. Řešení problémů
If you encounter issues with your wood stove, consider the following common troubleshooting steps:
- Poor Draft / Smoke Backing Up:
- Check if the chimney is blocked by creosote or debris.
- Ensure the smoke dampje otevřeno.
- Verify that there is adequate air supply to the room.
- Ensure the fuel is dry and properly seasoned.
- Nízký tepelný výkon:
- Confirm the fuel is dry and of good quality.
- Check if the air supply (front flap) is sufficiently open.
- Ensure the chimney is clean and providing good draft.
- Inspect door seals for leaks.
- Nadměrný kouř:
- This often indicates wet fuel. Use only dry wood.
- Ensure sufficient primary air is entering the combustion chamber.
- Check for chimney blockages.
If problems persist, contact a qualified technician or the retailer for assistance.
7. Specifikace
Image 4: Energy label for Prity FM E, showing energy efficiency class A and 12.1 kW output.
| Funkce | Hodnota |
|---|---|
| Model | FM E |
| Druh paliva | Dry woods with a moisture content of ≤20% |
| Třída energetické účinnosti | A |
| Index energetické účinnosti (EEI) | 104 |
| Sezónní energetická účinnost vytápění (ηs) | 69 % |
| Room Heating Output | 12.1 kW |
| Flue Gas Temperature at Nominal Heat Output | 227 °C |
| Energy Efficiency at Nominal Heat Output | 77.7 % |
| CO Emission (at 13% O₂) | 734 mg/Nm³ |
| PM Emission (at 13% O₂) | 24 mg/Nm³ |
| NOx Emission (at 13% O₂) | 105 mg/Nm³ |
| OGC Emission (at 13% O₂) | 18 mg/Nm³ |
| Exhaust Gas Mass Flow Rate | 9.3 g / s |
| Minimum Chimney Draft | 11 Pa |
| Průměr kouřovodu | 130 mm |
| Spotřeba paliva | 3.9 kg/h |
| Overall Dimensions (L x B x H) | 490 x 460 x 1050 mm |
| Combustion Chamber Dimensions (L x B x H) | 410 x 365 x 315 mm |
| Oven Dimensions (L x B x H) | 345 x 370 x 190 mm |
| Čistá hmotnost | 99 kg |
| Materiál těla | Steel (Body 2mm, Top 3-4mm) |
| Estimated Heating Area | 68 m² |
| Estimated Heating Capacity | 185 m³ |
8. Záruka a podpora
For warranty information, please refer to the terms and conditions provided by your retailer at the time of purchase. Keep your proof of purchase for any warranty claims.