1. Úvod
This manual provides detailed instructions for the installation, operation, and maintenance of the MYPIN FH4-4CRNB Digital Counter. Please read this manual thoroughly before using the device to ensure correct operation and to prevent damage.
2. Bezpečnostní informace
Vždy dodržujte následující bezpečnostní opatření:
- Zajistěte napájení objtagodpovídá specifikacím zařízení (90–260 V AC/DC).
- Před jakýmkoli zapojením kabeláže nebo prováděním údržby odpojte napájení.
- Installation and wiring should be performed by qualified personnel.
- Nepoužívejte zařízení v prostředí s nadměrnou vlhkostí, prachem nebo korozivními plyny.
- Avoid exposing the device to strong vibrations or impacts.
- Do not disassemble or modify the device; this will void the warranty.
3. Konec produktuview
The MYPIN FH4-4CRNB is a versatile digital counter designed for industrial applications. It features a clear display, multiple preset functions, and relay output for control. Its compact 48x48mm size makes it suitable for various panel installations.

Obrázek 3.1: Přední a boční view of the MYPIN FH4-4CRNB Digital Counter, showing the display, control buttons, and a simplified wiring diagram on the side label.
4. Specifikace
| Funkce | Specifikace |
|---|---|
| Model | FH4-4CRNB |
| Typ vstupu | Switch / Encoder |
| Typ výstupu | Relay Output (10kHz) |
| Napájení | 90-260V AC / DC |
| Přesnost | ±0.1% P.S |
| Rozměry | Rozměr 48 mm x 48 mm |
| Preset Capability | 4 předvoleb |
5. Instalace a montáž
The FH4-4CRNB counter is designed for panel mounting. Follow these steps for proper installation:
- Cut a panel cutout of 45mm x 45mm (approx.) in the desired mounting location.
- Insert the counter into the cutout from the front.
- Secure the counter using the provided mounting brackets from the rear of the panel.
- Zajistěte dostatečné větrání kolem zařízení, aby se zabránilo přehřátí.

Obrázek 5.1: Zadní view of the MYPIN FH4-4CRNB Digital Counter, showing ventilation slots for proper heat dissipation.
6. Schéma zapojení
Refer to the following diagrams for correct wiring connections. Always ensure power is disconnected before wiring.

Obrázek 6.1: Detailní view of the terminal block on the MYPIN FH4-4CRNB Digital Counter.

Figure 6.2: Wiring diagram as shown on the side label of the MYPIN FH4-4CRNB Digital Counter.
Připojení terminálu:
- Terminals 1 & 2 (NC, NO): Relay Output 1 (Normally Closed, Normally Open)
- Terminals 3 & 4 (NC, NO): Relay Output 2 (Normally Closed, Normally Open)
- Terminals 5 & 6 (NC, NO): Relay Output 3 (Normally Closed, Normally Open)
- Terminals 7 & 8 (NC, NO): Relay Output 4 (Normally Closed, Normally Open)
- Terminals 9 & 10 (90-260V): AC/DC Power Input (90-260V)
- Terminal 11 (RST): Resetovat vstup
- Terminal 12 (24V): 24V DC Auxiliary Power Output (for sensors, etc.)
- Terminal INA: Input A (for counting signal)
- Terminal INB: Input B (for counting signal, direction, or phase)
- Terminal GND: Ground for inputs
Poznámka: The specific function of INA and INB may vary based on the selected counting mode (e.g., single input, quadrature input). Refer to the device's on-screen menu for mode configuration.
7. Provoz
After successful wiring and power-up, the counter will display the current count. The front panel typically includes buttons for setting parameters and controlling the count.
Základní funkce:
- Počítací: The device counts pulses received on the input terminals (INA/INB).
- Preset Setting: Use the front panel buttons to navigate menus and set up to 4 preset values. When the count reaches a preset value, the corresponding relay output will activate.
- Resetovat: The count can be reset manually via a front panel button or externally via the RST input terminal.
- Výběr režimu: The counter supports various counting modes (e.g., up/down counting, batch counting, frequency measurement). These modes are typically configured through the device's internal menu system.
Detailed instructions for menu navigation and parameter setting are usually provided in the device's on-screen interface or a separate programming guide.
8. Údržba
The MYPIN FH4-4CRNB Digital Counter requires minimal maintenance. Follow these guidelines to ensure longevity:
- Čištění: Jemně otřete displej a casinměkkým, suchým hadříkem. Nepoužívejte abrazivní čisticí prostředky ani rozpouštědla.
- Inspekce: Pravidelně kontrolujte těsnost kabelových spojů a známky opotřebení nebo koroze.
- Prostředí: Zajistěte, aby provozní prostředí zůstalo v rámci specifikovaného rozsahu teploty a vlhkosti.
9. Řešení problémů
If you encounter issues with your digital counter, refer to the following common problems and solutions:
| Problém | Možná příčina | Řešení |
|---|---|---|
| Zařízení se nezapne. | Žádné napájení nebo nesprávná hlasitosttage. | Zkontrolujte připojení napájení a ujistěte se, že hlasitosttage is within 90-260V AC/DC. |
| Counter not counting. | Incorrect input wiring, faulty sensor, or incorrect counting mode. | Verify input wiring (INA, INB, GND). Test the sensor. Check counting mode settings in the menu. |
| Relay output not activating. | Preset value not reached, incorrect output wiring, or faulty relay. | Confirm the count has reached the preset. Check relay output wiring. Test the relay if possible. |
| Displej zobrazuje chybový kód. | Internal error or parameter setting issue. | Refer to the device's specific error code list (if available) or try resetting the device to factory defaults. |
10. Záruka a podpora
Information regarding product warranty and technical support was not provided in the available product data. Please refer to the retailer or manufacturer's official website for warranty terms and contact information for technical assistance.