Fluke 1507

Fluke 1507 Digital Megohmmeter Insulation Resistance Tester User Manual

Model: 1507

1. Úvod

The Fluke 1507 Digital Megohmmeter Insulation Resistance Tester is a robust and reliable instrument designed for comprehensive insulation testing in industrial and electrical environments. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your Fluke 1507 tester.

Key features include multiple insulation test voltages, automatic calculation of Polarization Index (PI) and Dielectric Absorption Ratio (DAR), a Compare (Pass/Fail) function for repetitive testing, and live circuit detection for enhanced safety.

2. Bezpečnostní informace

WARNING: Always read and understand all safety information before operating the Fluke 1507 tester. Failure to do so may result in serious injury or death.

3. Součásti a dodávané příslušenství

The Fluke 1507 Insulation Resistance Tester package typically includes the following items:

Fluke 1507 Insulation Tester with included accessories
Figure 3.1: The Fluke 1507 Insulation Tester shown with its standard included accessories, including test leads, probes, alligator clips, and the remote probe.

4. Nastavení

4.1. Instalace baterie

The Fluke 1507 requires four AA alkaline batteries for operation. These are typically included with the unit. To install or replace batteries:

  1. Ujistěte se, že je tester VYPNUTÝ.
  2. Vyhledejte přihrádku na baterie na zadní straně jednotky.
  3. Pomocí šroubováku otevřete kryt prostoru pro baterie.
  4. Insert the four AA batteries, observing the correct polarity as indicated inside the compartment.
  5. Nasaďte kryt prostoru pro baterie a zajistěte jej šroubem.

4.2. Připojení testovacích vodičů

Connect the test leads to the appropriate input jacks on the tester. For insulation resistance measurements, use the 'V Ω' and 'COM' jacks. Ensure connections are secure before proceeding with any tests.

5. Návod k obsluze

5.1. Zapnutí/vypnutí

To power on the Fluke 1507, rotate the rotary switch from the 'OFF' position to any desired measurement function. The large, backlit display will illuminate. To power off, rotate the switch back to 'OFF'. The unit also features an auto-power off function to conserve battery life.

Přední view of the Fluke 1507 Insulation Tester display and controls
Figure 5.1: The front panel of the Fluke 1507, showing the display, rotary switch, and function buttons.

5.2. Výběr testovacího objemutages

The Fluke 1507 offers multiple insulation test voltages. Rotate the main rotary switch to the 'INSULATION' section. Then, use the dedicated voltage selection buttons (50 V, 100 V, 250 V, 500 V, 1000 V) to choose the appropriate test voltage pro vaši aplikaci.

5.3. Performing Insulation Tests

Once the desired test voltage is selected and test leads are connected to the circuit under test:

  1. Stiskněte a podržte TEST button to initiate the insulation test. The display will show the measured insulation resistance.
  2. For hands-free operation during repetitive tests, utilize the remote test probe.
  3. The live circuit detection feature will prevent a test if voltage exceeds 30V, indicated by a warning on the display.
Fluke 1507 Insulation Tester held in a gloved hand during operation
Figure 5.2: The Fluke 1507 being held by a technician, demonstrating its compact and ergonomic design for field use.
Technician using Fluke 1507 to test an industrial motor
Figure 5.3: A technician performing an insulation test on an industrial motor using the Fluke 1507, highlighting its application in preventative maintenance.

5.4. Compare (Pass/Fail) Function

The Compare (Pass/Fail) function simplifies repetitive testing by allowing you to set a pass/fail threshold. Refer to the on-screen prompts and the user interface for setting this function. The tester will then indicate whether the measured resistance meets the predefined criteria.

5.5. Polarizační index (PI) a poměr dielektrické absorpce (DAR)

The Fluke 1507 automatically calculates Polarization Index (PI) and Dielectric Absorption Ratio (DAR), saving time and ensuring accurate assessment of insulation condition. These functions are typically accessed via dedicated buttons on the front panel.

Technician using Fluke 1507 with magnetic hanging system for overhead work
Figure 5.4: A technician utilizing the optional magnetic hanging system with the Fluke 1507, allowing for hands-free operation during overhead electrical work.

6. Údržba

6.1. Čištění

To clean the exterior of the tester, use a damp cloth and a mild detergent. Do not use abrasive cleaners or solvents. Ensure the unit is completely dry before storage or next use.

6.2. Výměna baterie

Replace batteries when the low battery indicator appears on the display. Refer to Section 4.1 for detailed battery installation instructions. Always use fresh alkaline batteries.

6.3. Kalibrace

For optimal performance and accuracy, periodic calibration by an authorized service center is recommended. Refer to your warranty information or contact Fluke support for calibration schedules and services.

7. Řešení problémů

This section provides solutions to common issues you might encounter with your Fluke 1507 tester.

ProblémMožná příčinaŘešení
Tester se nezapne.Vybité nebo nesprávně vložené baterie.Zkontrolujte polaritu baterií a vyměňte je za nové baterie typu AA.
Insulation test does not start.Živá svtage detected on the circuit.Ensure the circuit is de-energized or voltage is below 30V. The tester will not perform an insulation test if live voltage is present for safety.
Nepřesné údaje.Damaged test leads or improper connection.Inspect test leads for damage. Ensure leads are securely connected to the tester and the circuit.
Displej je tlumený nebo bliká.Slabá baterie.Vyměňte baterie.

8. Specifikace

SpecifikaceHodnota
ZnačkaFluke
Číslo modelu1507
Zdroj napájeníNapájení z baterií (4 AA baterií)
Zkouška izolace svtages50 V, 100 V, 250 V, 500 V, 1000 V
Min. Provozní svtage50 V (DC)
svtage Hodnocení600 voltů
Přesnost měření+/-0.5 %
Hmotnost položky2.2 libry (1 kilogram)
Rozměry produktu (D x Š x V)11.77 x 15.2 x 3.07 palce
MateriálPlast
BarvaŽluť
DodržováníEN 61010-1, CAT IV 600 V
Zahrnuté komponentyRemote probe, test leads, test probes, alligator clips

9. Záruka a podpora

9.1. Informace o záruce

The Fluke 1507 Digital Megohmmeter Insulation Resistance Tester comes with a 1-Year warranty. Please retain your proof of purchase for warranty claims. The warranty covers defects in materials and workmanship under normal use.

9.2. Zákaznická podpora

For technical assistance, service, or to inquire about calibration services, please visit the official Fluke website or contact their customer support. You can also refer to the comprehensive User Manual (PDF) available online for more detailed information:

Související dokumenty - 1507

Předview Uživatelská příručka k testeru izolace Fluke 1535/1537/1537-II
Komplexní uživatelská příručka pro testery izolace Fluke 1535, 1537 a 1537-II, která zahrnuje funkce, provoz, testovací postupy, údržbu a specifikace.
Předview Uživatelská příručka k měřiči izolace Fluke 1550C/1555
Uživatelská příručka pro testery izolace Fluke 1550C a 1555, s podrobným popisem funkcí, obsluhy, měření, údržby a specifikací.
Předview Fluke SMFT-1000: Voc and Operational Current Testing Guide for PV Systems
This application note from Fluke Corporation details how to perform Voc (Open Circuit Voltage) and Ioperational (Operational Current) tests on photovoltaic (PV) modules and strings using the Fluke SMFT-1000 tester, adhering to IEC 62446-1 standards. It provides step-by-step instructions and explains the interpretation of test results for ensuring PV system performance and identifying wiring faults.
Předview Uživatelská příručka k zkoušečům izolace Fluke 1507/1503
Komplexní uživatelská příručka pro testery izolace Fluke 1507 a 1503, s podrobným popisem obsluhy, bezpečnostních opatření, postupů měření, technických specifikací a údržby.
Předview Fluke SMFT-1000 Multifunction PV Analyzer Quick Reference Guide
A quick reference guide for the Fluke SMFT-1000 Multifunction PV Analyzer, providing step-by-step instructions for essential solar photovoltaic system tests including loop resistance, polarity, Voc/Isc, insulation resistance, and I-V curve tracing.
Předview Sada ověřovací jednotky Fluke T5-1000 / PRV240: Technické údaje a informace pro objednání
Komplexní technické údaje a informace pro objednání elektrického testeru Fluke T5-1000 a sady zkušební jednotky PRV240 s podrobnými specifikacemi produktu, komponenty a kontaktními údaji společnosti Fluke Corporation.