The DIGITEN TTC-1003 is a versatile 3-stage outlet temperature controller designed for precise environmental management. It features two temperature-controlled outlets and one timer-controlled outlet, allowing for independent regulation of heating, cooling, and lighting cycles. This device is suitable for a wide range of applications, including reptile habitats, incubators, greenhouses, mushroom cultivation, and home brewing. This manual provides detailed instructions for the safe and effective operation of your TTC-1003 controller.

Figure 1: DIGITEN TTC-1003 Temperature Controller
2. Bezpečnostní informace
Před použitím zařízení si prosím přečtěte a pochopte všechny bezpečnostní pokyny. Nedodržení těchto pokynů může vést k úrazu elektrickým proudem, požáru nebo poškození produktu.
- Zajistěte napájení objtage matches the specifications of the controller (100-240V AC).
- Do not immerse the main controller unit in water or expose it to excessive moisture. The temperature probes are waterproof, but the main unit is not.
- Always unplug the device from the power outlet before cleaning or performing any maintenance.
- Do not exceed the maximum rated current of 15A for the entire unit.
- Udržujte zařízení mimo dosah dětí a domácích zvířat.
- Do not disassemble or modify the controller. Refer all servicing to qualified personnel.
- Ensure all connected appliances are in good working condition and do not exceed the controller's wattage limity.
3. Konec produktuview
3.1 Komponenty
- DIGITEN TTC-1003 Controller Unit
- 2 x Temperature Sensor Probes (2m / 78.74in each)
- Power Cord (1.4m / 55.12in)
3.2 Klíčové vlastnosti
- Snadné použití: Plug-and-play design with a large LCD display.
- Nezávislé ovládání: Two temperature-controlled outlets (OUT1, OUT2) and one timer-controlled outlet (OUT3) operate independently.
- Široký teplotní rozsah: Regulates and maintains temperatures from 14°F to 248°F (-10°C to 120°C).
- Duální senzorové sondy: Two probes for reliable temperature tracking.
- Regulace teploty ve dne/v noci: Allows for different temperature settings for day and night cycles on temperature-controlled outlets.
- Funkce časování: Outlet 3 offers a time cycle function for lighting or other timed devices.
- Funkce paměti: All settings are saved in the event of a power outage.
- Přepínač jednotky teploty: Snadné přepínání mezi stupni Celsia (°C) a Fahrenheita (°F).
- Alarm vysoké/nízké teploty: Provides alerts for temperature deviations.

Figure 2: Key Features of the TTC-1003
4. Pokyny k nastavení
4.1 Počáteční umístění
- Choose a dry, stable location for the controller unit, away from direct sunlight or heat sources.
- The unit can be wall-mounted using the integrated hanging slot on the back.

Figure 3: Wall-Mounted Installation
4.2 Connecting Probes and Devices
- Plug the two temperature sensor probes into the designated ports on the top of the controller.
- Position the sensor probes in the environment where temperature monitoring is required. Ensure they are not directly exposed to heating elements or water if not intended.
- Plug your heating or cooling devices into OUT1 and OUT2. These outlets are temperature-controlled.
- Plug your lighting or other timed devices into OUT3. This outlet is timer-controlled.
- Plug the controller's power cord into a standard electrical outlet. The LCD display will illuminate.

Obrázek 4: Přample Applications and Connections
5. Návod k obsluze
The controller features a large LCD display and three buttons: SOUBOR, HODINYa Šipky NAHORU/DOLŮ.
5.1 Nastavení aktuálního času
- Stiskněte a podržte HODINY tlačítko po dobu 3 sekund, dokud nezačne blikat číslice hodin.
- Použijte Šipky NAHORU/DOLŮ upravit hodinu.
- Stiskněte HODINY again to move to the minute digit, then adjust with Šipky NAHORU/DOLŮ.
- Stiskněte HODINY pro potvrzení a ukončení.
5.2 Temperature Control (Outlets 1 & 2)
Outlets 1 and 2 are independently controlled for temperature. Each can be set for heating or cooling mode with specific ON/OFF temperatures and operating times.
- Stiskněte a podržte SOUBOR button for 3 seconds to enter programming mode. The display will show 'OUT1' or 'OUT2' and the first setting will flash.
- Použijte Šipky NAHORU/DOLŮ to select 'OUT1' or 'OUT2'. Press SOUBOR potvrdit.
- Nastavení času zapnutí: The 'ON' time will flash. Use Šipky NAHORU/DOLŮ pro nastavení hodiny a poté stiskněte SOUBOR to set minutes. This is the time when temperature control for this outlet begins.
- Nastavení času vypnutí: The 'OFF' time will flash. Use Šipky NAHORU/DOLŮ pro nastavení hodiny a poté stiskněte SOUBOR to set minutes. This is the time when temperature control for this outlet ends.
- Set ON Temperature: The 'ON Temp' will flash. Use Šipky NAHORU/DOLŮ to set the temperature at which the connected device turns ON.
- Set OFF Temperature: The 'OFF Temp' will flash. Use Šipky NAHORU/DOLŮ to set the temperature at which the connected device turns OFF.
- Determine Mode (Heating/Cooling):
- If ON Temp < OFF Temp: The controller operates in Režim topení. The device turns on when the temperature drops to ON Temp and turns off when it reaches OFF Temp.
- If ON Temp > OFF Temp: The controller operates in Režim chlazení. The device turns on when the temperature rises to ON Temp and turns off when it reaches OFF Temp.
- Stiskněte SOUBOR to cycle through additional settings (High Alarm, Low Alarm, Calibration) or press HODINY uložit a ukončit.

Figure 5: Temperature Control Programming Example
5.3 Timer Control (Outlet 3)
Outlet 3 operates as a simple timer, allowing for two independent ON/OFF periods within a 24-hour cycle.
- Stiskněte a podržte SOUBOR button for 3 seconds to enter programming mode.
- Použijte Šipky NAHORU/DOLŮ to select 'OUT3'. Press SOUBOR potvrdit.
- Set First ON Time: The 'ON' time for the first period will flash. Adjust with Šipky NAHORU/DOLŮ a potvrďte pomocí SOUBOR.
- Set First OFF Time: The 'OFF' time for the first period will flash. Adjust with Šipky NAHORU/DOLŮ a potvrďte pomocí SOUBOR.
- Opakujte kroky pro Second ON Time a Second OFF Time if a second timed period is desired. If not, set the second ON time to be the same as the second OFF time to disable it.
- Stiskněte HODINY uložit a ukončit.

Figure 6: Timer Control Programming Example for Outlet 3
5.4 Výběr teplotní jednotky (°C/°F)
To switch between Celsius and Fahrenheit, briefly press the Šipka nahoru button while in normal operating mode.
5.5 High/Low Temperature Alarms (AH/AL)
You can set high and low temperature alarms for Outlets 1 and 2 to be notified if the temperature goes outside your desired range.
- Enter programming mode for OUT1 or OUT2 (as described in 5.2).
- After setting ON/OFF temperatures, press SOUBOR until 'AH' (High Alarm) flashes. Use Šipky NAHORU/DOLŮ to set the desired high temperature limit.
- Stiskněte SOUBOR until 'AL' (Low Alarm) flashes. Use Šipky NAHORU/DOLŮ to set the desired low temperature limit.
- Stiskněte HODINY uložit a ukončit.
6. Údržba
Regular maintenance ensures the longevity and accuracy of your DIGITEN TTC-1003 controller.
- Čištění: Wipe the controller unit with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the unit is unplugged before cleaning.
- Péče o sondu: Periodically inspect the temperature probes for any signs of damage or wear. Ensure the probes are clean for accurate readings. The probes are waterproof and can be cleaned with a damp tkanina.
- Skladování: If storing the device for an extended period, unplug it and store it in a cool, dry place.

Figure 7: Waterproof Temperature Probe
7. Řešení problémů
If you encounter issues with your controller, refer to the table below for common problems and solutions.
| Problém | Možná příčina | Řešení |
|---|---|---|
| Displej je prázdný nebo se nezapíná. | Žádné napájení. | Check if the controller is properly plugged into a live outlet. Verify the power outlet is functional. |
| Heating/Cooling device (OUT1/OUT2) not turning on/off. | Incorrect temperature settings (ON Temp/OFF Temp). Incorrect time period settings. Porucha zařízení. | Review and adjust ON/OFF temperatures and time periods. Ensure the ON/OFF temperatures are set correctly for heating (ON < OFF) or cooling (ON > OFF). Test the connected device directly in a wall outlet. |
| Timed device (OUT3) not turning on/off. | Incorrect ON/OFF times for OUT3. | Verify the programmed ON/OFF times for Outlet 3. Ensure the current time on the controller is accurate. |
| Údaje o teplotě jsou nepřesné. | Probe placement or damage. Je nutná kalibrace. | Ensure probes are correctly positioned and not directly touching heating elements. Check probes for visible damage. Use the calibration setting (refer to section 5.5) to adjust the temperature reading if necessary (within +/- 12°F). Note that readings are typically accurate within 1-2°F. |
| Nastavení se po výpadku napájení ztratítage. | This should not occur as the device has memory backup. | If settings are consistently lost, contact customer support. |
8. Specifikace
| Funkce | Detail |
|---|---|
| Název modelu | TTC-1003 |
| Značka | DIGITEN |
| Rozsah regulace teploty | 14 °F ~ 248 °F (-10 °C ~ 120 °C) |
| svtage | 100-240V AC |
| Jmenovitý proud | 15A Max |
| Wattage | 2200W |
| Typ zobrazení | LCD s podsvícením |
| Typ ovládání | Stiskněte tlačítko |
| Technologie připojení | Předem zapojené |
| Hmotnost položky | 1.03 libry (přibližně 0.47 kg) |
| Rozměry balení | 6.54 x 6.34 x 2.05 palce |
9. Záruka a podpora
9.1 Záruka na produkt
DIGITEN provides a one-year warranty for any quality problems with this product. Please retain your proof of purchase for warranty claims.
9.2 Zákaznická podpora
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact DIGITEN customer support. You can find contact information and additional resources by visiting the official DIGITEN store: