1. Úvod
This manual provides essential information for the safe and effective installation, operation, and maintenance of your Intermatic T104M Mechanical Time Switch Mechanism. This mechanism is designed for integration into compatible Intermatic enclosures (sold separately) and is ideal for automating various electrical loads such as pumps, fans, lighting, and high-voltage zařízení.
2. Bezpečnostní informace
VAROVÁNÍ: Nebezpečí požáru nebo úrazu elektrickým proudem.
- Always turn OFF power at the main circuit breaker or fuse box before installing, servicing, or removing the time switch mechanism. Failure to do so may result in serious injury or death.
- Tento výrobek vás může vystavit chemikáliím, včetně olova, o kterém je ve státě Kalifornie známo, že způsobuje rakovinu a vrozené vady nebo jiné reprodukční poškození. Více informací naleznete na www.P65Warnings.ca.gov.
- Ujistěte se, že všechna elektroinstalace jsou bezpečná a splňují místní a národní elektrotechnické předpisy.
- Do not remove the plastic insulator covering the terminals. It must be replaced after wiring to ensure safety.

Figure 1: Intermatic T104M Mechanical Time Switch Mechanism. This image shows the front view of the mechanism, highlighting the yellow dial, manual lever, and wiring terminals.
3. Nastavení a instalace
The T104M is a mechanism-only unit designed for integration into existing or new compatible Intermatic enclosures. It does not come with an enclosure.
3.1. Příprava na instalaci
- Vypnout napájení: Locate the circuit breaker or fuse that controls the power to the timer's location and turn it OFF. Verify power is off using a voltage tester.
- Access Enclosure: Open the existing Intermatic enclosure where the T104M mechanism will be installed or replaced.
- Remove Old Mechanism (if replacing): If replacing an old mechanism, carefully disconnect all wires from the terminals. Note the wiring configuration or take a photo for reference. Push the retaining tab at the top of the mechanism and lift it out of the enclosure's side slots.

Obrázek 2: Shora dolů view of the T104M mechanism, showing the gear assembly and mounting points.
3.2. Instalace nového mechanismu
- Vkládací mechanismus: Align the new T104M mechanism with the slots in the enclosure. Push the mechanism into place until the top retaining tab clicks securely.
- Kabelová připojení: Connect the electrical wires to the appropriate terminals on the mechanism. The T104M is a Double Pole, Single Throw (DPST) switch. Refer to the wiring diagram on your enclosure or the product's specifications for correct connections. Ensure all wire connections are tight and secure.
- Replace Insulator: Ensure the plastic insulator covering the terminals is properly in place. This is crucial for safety.
- Zavřít přílohu: Close the enclosure door securely.
- Obnovit napájení: Znovu zapněte napájení hlavním jističem nebo pojistkovou skříní.
4. Návod k obsluze
The T104M features a 24-hour mechanical scheduling dial with ON/OFF trippers for automated control.
4.1. Nastavení aktuálního času
- Locate the yellow time dial.
- Gently pull the entire dial outwards.
- Rotate the dial clockwise or counter-clockwise until the current time aligns with the time pointer (usually a small arrow or line on the mechanism's frame).
- Once the correct time is set, release the dial. It should snap back into place.
4.2. Setting ON/OFF Events
The mechanism comes with one ON (green) and one OFF (red) tripper. Additional trippers can be purchased separately to allow for up to 12 ON/OFF events per day.
- Attach Trippers: If not already attached, slide the ON and OFF trippers onto the outer edge of the time dial at your desired ON and OFF times.
- Adjust Trippers: To adjust a tripper, loosen the small screw on the tripper, slide it to the desired time on the dial, and then tighten the screw to secure it. Ensure the trippers are firmly in place to engage the manual lever.
- The dial will continuously rotate, and when the time pointer reaches an ON tripper, the switch will activate. When it reaches an OFF tripper, the switch will deactivate.
4.3. Ruční ovládání
A manual lever is provided for temporary ON/OFF control without affecting the programmed schedule.
- To manually turn the load ON or OFF, simply push the manual lever to the desired position (ON or OFF).
- The next programmed tripper will override the manual setting and resume the automatic schedule.
5. Údržba
The Intermatic T104M is designed for durability and requires minimal maintenance. However, periodic checks can ensure optimal performance.
- Pravidelná kontrola: Periodically inspect the mechanism for any signs of wear, corrosion, or debris buildup, especially on the gears and electrical contacts.
- Čištění: Gently clean any dust or dirt from the mechanism using a soft, dry cloth. Avoid using liquids or abrasive cleaners.
- Kontaktní místa: If the electrical contacts appear discolored or show signs of arcing, they may need to be gently cleaned or filed by a qualified electrician.
- Bezpečnost cestovatelů: Ensure that the ON and OFF trippers are securely fastened to the dial. Loose trippers may lead to inaccurate scheduling.
6. Řešení problémů
6.1. Timer Dial Not Turning
- Zkontrolujte napájení: Ensure the timer is receiving power. Verify the circuit breaker is ON.
- Porucha motoru: The internal clock motor may have failed. This is a common issue after extended use (e.g., 15+ years). The mechanism will need to be replaced.
- Gear Issues: Inspect the gears behind the dial. If teeth are broken or stripped, the mechanism will need replacement.
6.2. Load Not Turning ON/OFF at Programmed Times
- Tripper Placement: Verify that the ON and OFF trippers are correctly positioned and securely tightened on the dial at the desired times.
- Manual Lever Position: Check if the manual lever is in the correct position. Remember that the next tripper will override the manual setting.
- Elektrické kontakty: Over time, the internal electrical contacts may become worn or corroded, preventing proper connection. This typically requires mechanism replacement.
- Zapojení: Ensure all wiring connections are secure and not loose.
7. Specifikace
| Značka | Intermatic |
| Číslo modelu | T104M |
| Rozměry produktu | 2.5"H x 5"Š x 8"V |
| Hmotnost položky | 1 libra |
| Materiál | Akrylonitril-butadien-styren |
| Časové období | 24 hodina |
| Počet nastavení | 12 ON/OFF events per day |
| Kontaktní formulář | DPST (Double Pole, Single Throw) |
| svtage Hodnocení | 208-277 Volts AC (Clock Motor) / 120-480V (Resistive Loads) |
| Aktuální hodnocení | Až 40A |
| Motor Load Capacity | Up to 5 HP at 240V, 2 HP at 120V |
| Certifikace | UL and CSA certified |

Figure 3: Certification logos for the Intermatic T104M mechanism.
8. Záruka a podpora
8.1. Informace o záruce
The Intermatic T104M Mechanical Time Switch Mechanism comes with a 1-letá záruka od data nákupu. Uschovejte si prosím doklad o koupi pro případné reklamace.
8.2. Další podpora
For detailed wiring diagrams, advanced troubleshooting, or to download the complete user manual in PDF format, please visit the official Intermatic webweb nebo se podívejte na poskytnuté zdroje:
- Uživatelská příručka (PDF): Stáhněte si uživatelskou příručku
- Intermatic Store: Visit Intermatic Brand Store on Amazon