Eaton CHPSURGE

Eaton CHPSURGE Plug-On Neutral Surge Protective Device

Návod k použití

1. Úvod

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Eaton CHPSURGE Plug-On Neutral Surge Protective Device (SPD). This Type 2 SPD is designed to protect your home's electrical system and connected equipment from damaging power surges. Please read this manual thoroughly before installation or use.

2. Bezpečnostní informace

VAROVÁNÍ: Risk of electric shock. Installation and servicing of this device must be performed by qualified electrical personnel only. Failure to follow these instructions may result in serious injury or death.

  • Always disconnect power at the main service panel before installing or servicing the surge protective device.
  • Ověřte, že je napájení vypnuto pomocí voltage testeru, než budete pokračovat.
  • Během instalace se ujistěte, že jsou dodržovány všechny místní a národní elektrotechnické předpisy.
  • Do not install this device in a wet or damp umístění.

3. Konec produktuview

The Eaton CHPSURGE is a 2-pole, plug-on neutral surge protective device designed for use in Eaton CH series load centers. It provides whole-home surge protection by diverting harmful transient voltages away from sensitive electronics. The device features a green LED indicator to confirm operational status.

Eaton CHPSURGE Plug-On Neutral Surge Protective Device

Obrázek 1: Přední strana view of the Eaton CHPSURGE device. This image shows the compact, black housing of the surge protective device, with the Eaton logo and 'SURGE PROTECTOR' label visible. A green indicator light is present, labeled 'PROTECTED WHEN LIT', signifying operational status. The model number 'CHPSURGE' is also clearly displayed.

Eaton CHPSURGE Packaging

Image 2: Eaton CHPSURGE device alongside its retail packaging. The packaging displays the Eaton logo, 'CHPSURGE', 'QTY. 1', and 'SURGE-PROTECTIVE DEVICE TYPE 2', along with voltage ratings '120 / 240 V~' and '2 POLE'. A barcode with the number 786689353674 is also visible.

4. Nastavení (instalace)

The Eaton CHPSURGE is a permanently connected device designed for installation within a compatible Eaton CH series load center. It is installed on the load side of the service entrance overcurrent protective device.

  1. Odpojení napájení: Locate your main electrical panel and turn off the main breaker to completely de-energize the panel. Verify power is off using a voltage tester.
  2. Přístup k panelu: Carefully remove the cover of your electrical panel.
  3. Umístění zařízení: Identify two adjacent available spaces in your Eaton CH series load center. The CHPSURGE device is a 2-pole breaker form factor.
  4. Instalace: Insert the CHPSURGE device into the two available breaker slots. Ensure it is firmly seated on the bus bar. The plug-on neutral feature simplifies connection to the neutral bus.
  5. Zapojení: Connect the neutral wire from the surge protective device to the neutral bus bar in the panel. Connect the ground wire to the ground bus bar. Ensure all connections are tight and secure.
  6. Uzavření panelu: Replace the electrical panel cover, ensuring all wires are clear of the cover and screws.
  7. Obnovení napájení: Turn the main breaker back on. The green LED indicator on the CHPSURGE device should illuminate, indicating it is operational and providing protection.

5. Provoz

Once properly installed and power is restored, the Eaton CHPSURGE device operates continuously to protect your electrical system. The green LED indicator on the front of the device signifies that the surge protection is active and functioning correctly. The device automatically detects and diverts harmful voltage surges, protecting your home's electrical circuits and connected appliances.

6. Údržba

The Eaton CHPSURGE device requires minimal maintenance. Periodically check the green LED indicator on the front of the device. As long as the LED is illuminated, the device is providing surge protection.

  • Kontrola LED indikátoru: Visually inspect the device's LED indicator at least once a month.
  • Device Replacement: If the green LED indicator is off, it signifies that the device has absorbed a significant surge event and is no longer providing protection. The device must be replaced immediately to restore surge protection.

7. Řešení problémů

ProblémMožná příčinaŘešení
Green LED indicator is off.The device has absorbed a surge and is no longer functional.Replace the Eaton CHPSURGE device with a new one.
No power to the panel after installation.Main breaker is off or tripped.Ensure the main breaker in your electrical panel is in the 'ON' position. If it tripped, reset it.
Device does not fit in panel.Incorrect panel type.This device is designed for Eaton CH series panels only. Verify your panel type. Do not attempt to force installation into incompatible panels.

8. Specifikace

  • Typ produktu: Type CH Circuit Breaker Surge Protective Device
  • Poláci: Dva póly
  • Typ připojení: Plug-On neutrální
  • Surge Protection Type: Typ 2 SPD
  • Hodnocení zkratu: 10 kA
  • Hodnocení přerušení: 10 kAIC
  • Hodnocení frekvence: 50/60 Hz
  • Rázový proud: 18 kA
  • Maximální nepřetržitý provozní objemtage (MCOV): 150 V LN, 300 V LL
  • svtage: 240 voltů
  • certifikace: UL 1449 3rd Edition Listed
  • Rozměry produktu: Přibližně 7 x 4 x 0.01 palce
  • Hmotnost položky: Přibližně 7 unce

9. Záruka a podpora

Eaton products are manufactured to high-quality standards and are backed by a manufacturer's warranty. For specific warranty details, terms, and conditions, please refer to the documentation included with your purchase or visit the official Eaton webmísto.

For technical assistance, troubleshooting beyond the scope of this manual, or to inquire about replacement parts, please contact Eaton customer support. Have your product model number (CHPSURGE) and purchase information ready when contacting support.

Oficiální Eaton Webmísto: www.eaton.com

Související dokumenty - CHPSURGE

Předview Eaton SP1 Surge Protective Device: Installation and Operation Manual
Comprehensive installation and operation manual for the Eaton SP1 Surge Protective Device (SPD). Covers safety, mounting, wiring, specifications, and warranty for electrical systems.
Předview Eaton Innovative Technology Equalizer 2 Series Surge Protective Device Quick Start Guide
Quick start guide for the installation, wiring, and operation of Eaton's Innovative Technology Equalizer 2 Series Surge Protective Device (SPD). Includes safety precautions, installation methods, wiring diagrams, operation, maintenance, and warranty information.
Předview Seznam technických publikací Eaton Aerospace Master
Komplexní rejstřík technických publikací pro produkty společnosti Eaton Aerospace s podrobnými informacemi o číslech dílů, číslech modelů, typech dokumentů, datech vydání, platformách letadel a výrobních závodech. Tento seznam slouží jako klíčový zdroj pro údržbu a servis leteckých komponentů.
Předview Eaton AG II IT DN Series Surge Protective Device Installation Instructions
Installation instructions and technical specifications for Eaton's AG II IT DN Series AC Surge Protective Devices (SPDs), covering setup, safety, and performance data.
Předview Kompletní návod k instalaci a obsluze přepěťové ochrany Eaton pro domácnosti
Tato příručka obsahuje podrobné pokyny k instalaci a provozu systému přepěťové ochrany Eaton CHSP Complete Home, včetně bezpečnostních opatření, montáže, zapojení a řešení problémů s elektrickými systémy v domácnostech.
Předview Katalog proudových chráničů Eaton xEffect FRCmM
Komplexní katalog s podrobnými informacemi o proudových chráničích (RCD) řady Eaton xEffect FRCmM, včetně technických specifikací, typů (AC, A, F, G, S, U, R), aplikací a produktových dat pro průmyslové elektroinstalace.