Renogy SUNDCCB160MC2P

Renogy Suntree 160 Amp Návod k obsluze 2pólového DC jističe

Model: SUNDCCB160MC2P

1. Konec produktuview

The Suntree DC Molded Case Circuit Breaker is engineered to safeguard DC electrical installations from overloads and short circuits. It incorporates both thermal and magnetic tripping mechanisms for reliable protection. Upon detecting a fault, the circuit breaker automatically interrupts the electrical circuit, preventing wire damage and reducing fire risk. This device can also be manually opened under its full rated load for electrical maintenance without sustaining damage. Designed for reversible connection, the circuit breaker can be wired in either direction and supports bidirectional current flow. Clear markings on the handle indicate the contact position (ON/OFF) at a glance. Its design facilitates easy installation on both standard DIN rails and vertical surfaces.

Renogy Suntree 160 Amp 2-Pole DC Circuit Breaker

Figure 1: Renogy Suntree 160 Amp 2-Pole DC Circuit Breaker

2. Bezpečnostní informace

  • Před instalací nebo servisem jističe vždy odpojte napájení.
  • Installation should be performed by qualified personnel in accordance with local electrical codes and standards.
  • Ensure proper wire sizing and terminal connections to prevent overheating.
  • Nepoužívejte jistič, pokud se jeví poškozený.
  • Při práci s elektrickými systémy používejte vhodné osobní ochranné prostředky (OOP).

3. Instalace

3.1 Obsah balení

  • 160A 2P DC Molded Case Circuit Breaker
  • Montážní šrouby
  • Insulation Barrier (2 pieces)
Dimensions and included components of the circuit breaker

Figure 2: Product Dimensions and Included Components

3.2 Montáž

The circuit breaker supports both DIN rail and vertical surface mounting. Ensure the mounting location is dry, well-ventilated, and protected from direct sunlight and extreme temperatures.

Diagram showing quick installation on DIN rail with insulation barriers

Figure 3: Quick Installation on DIN Rail

3.3 Zapojení kabeláže

Connect the DC positive and negative cables to the corresponding terminals on the circuit breaker. The circuit breaker is designed for reversible connection and functions with bidirectional current. Ensure all connections are secure and tight. Install the provided insulation barriers between terminals for enhanced safety.

Wiring diagram showing positive and negative connections to the circuit breaker

Obrázek 4: Schéma zapojení

3.4 Sizing Tips for Circuit Breaker Selection

Proper sizing is crucial for effective protection.

  • For controller/inverter/DC device:
    1. Determine the maximum continuous operating current (current = watt/voltagE).
    2. Calculate maximum current = 1.25 x maximum continuous operating current.
    3. Select a circuit breaker whose rated current is greater than and closest to the calculated maximum current.
  • For solar panel:
    1. Determine the short-circuit current.
    2. Calculate maximum current = Short-circuit current x 1.25 x 1.25.
    3. Select a circuit breaker whose rated current is greater than and closest to the calculated maximum current.
Diagram illustrating sizing tips for circuit breakers in solar systems

Figure 5: Circuit Breaker Sizing Guidelines

4. Provoz

4.1 Zapnutí/vypnutí

To switch the circuit breaker ON, push the handle to the 'ON' position. To switch it OFF, push the handle to the 'OFF' position. The handle's position clearly indicates the contact status.

Image showing the ON and OFF positions of the circuit breaker handle

Figure 6: ON/OFF Markings

4.2 Ochranné mechanismy

The circuit breaker provides protection against both overload and short-circuit conditions. In the event of an electrical fault, the breaker will automatically trip to protect the system.

Diagram illustrating overload and short-circuit protection features

Figure 7: Overload and Short-circuit Protection

5. Údržba

After the circuit breaker has tripped due to a fault, it can be reset manually. No damage occurs to the breaker itself from tripping. Regular visual inspection for any signs of wear or damage is recommended. Ensure connections remain tight.

Diagram showing mechanical and electrical life cycles, and high electrical conductivity

Figure 8: Durability and Conductivity

6. Řešení problémů

  • Breaker trips frequently: This indicates an overload or short circuit in the system. Identify and resolve the underlying electrical issue before resetting the breaker.
  • Breaker does not reset: Ensure the fault condition has been cleared. If the breaker still does not reset, it may be damaged and require replacement.
  • No power after installation: Verify all wiring connections are correct and secure. Check for proper input voltage and ensure the breaker is in the 'ON' position.

7. Specifikace

FunkceSpecifikace
ZnačkaRenogy
Aktuální hodnocení160 Amps
Typ jističeNorma
Typ montážePovrchová montáž
Počet Poláků2
UPC810009719694
VýrobceRenogy
Číslo díluSUNDCCB160MC2P
Hmotnost položky5.15 libry
Rozměry produktu7.9 x 3.5 x 5.3 palce
MateriálMěď
Zahrnuté komponenty160A 2P DC Molded Case Circuit Breaker, Mounting Screws, Insulation Barrier

8. Záruka a podpora

Renogy offers a 1-year material and workmanship warranty for this product. For technical support or warranty claims, please visit the official Renogy webnebo kontaktujte jejich zákaznický servis.

Pro více informací navštivte Renogy Store.

Související dokumenty - SUNDCCB160MC2P

Předview Renogy Off-Grid Solar Kit General Manual: Installation and Operation Guide
This manual provides comprehensive instructions for installing, wiring, and maintaining the Renogy Off-Grid Solar Kit. Learn about safety precautions, mounting systems, battery configurations, and system connections for reliable off-grid power.
Předview Uživatelská příručka k solární sadě Renogy pro použití mimo síť: Průvodce instalací, zapojením a montáží
Komplexní uživatelská příručka pro solární sady Renogy pro použití v zahraničí, která zahrnuje instalaci, zapojení, montážní systémy (Z-držák, lišta, sloup), konfigurace baterií, bezpečnostní opatření a použití pojistek ANL pro obytné vozy, lodě a nezávislé napájecí systémy.
Předview Renogy Battery Shunt 300 Uživatelská příručka
Komplexní uživatelská příručka pro Renogy Battery Shunt 300, která poskytuje pokyny k instalaci, provozu, konfiguraci a řešení problémů s inteligentním monitorováním baterií v solárních a offline systémech.
Předview Stručný průvodce Renogy ONE Core | Instalace a provoz
Stručný návod k instalaci, připojení a základnímu ovládání zařízení Renogy ONE Core (RSHGWSN-W02W-G3). Naučte se, jak nastavit zařízení Renogy ONE Core pro optimální výkon.
Předview Uživatelská příručka a technické specifikace modulu Bluetooth Renogy BT-2
Komplexní průvodce Bluetooth modulem Renogy BT-2 s podrobným popisem jeho funkcí, identifikace součástí, provozu, technických specifikací a připojení aplikace pro solární regulátory nabíjení.
Předview Uživatelská příručka Renogy ONE Core: Komplexní průvodce monitorováním energie a integrací chytré domácnosti
This user manual provides detailed instructions for the Renogy ONE Core, covering installation, operation, features like RV leveling and smart home integration, troubleshooting, and technical specifications. Learn how to monitor and manage your energy systems effectively.