This manual provides essential information for the safe and efficient operation of your HKS 2.2KW (3HP) 220V Variable Frequency Drive (VFD). This device is designed to control the speed of three-phase AC motors, commonly used in applications such as CNC routers, spindle motors, grinders, mixers, conveyors, treadmills, centrifugals, elevators, lathes, and extruders. Please read this manual thoroughly before installation and operation.
Key features of this VFD include:
- Intuitive Display and Buttons: The VFD features a user-friendly display and control buttons for quick setup and operation. The control panel can be detached for remote control applications.
- Komplexní ochrana: Equipped with multiple protection mechanisms including overload, fuse, overvoltage, podpaltage, restart, stall, short circuit, and overheat protection.
- Provoz s nízkou hlučností: Advanced PWM control technology and optimized component design contribute to reduced noise and electromagnetic interference, enhancing product longevity.
- Všestranný vstup/výstup: Supports single-phase or three-phase 220V input and provides three-phase 0-400Hz output.
2. Bezpečnostní informace
VAROVÁNÍ: Improper installation or operation can result in serious injury or death. Always follow safety precautions.
- Ensure all power is disconnected before installation, wiring, or maintenance.
- Toto zařízení by měl instalovat a servisovat pouze kvalifikovaný personál.
- Ověřte vstupní objtage matches the VFD's specifications (AC 220V, 180-250V).
- Do not connect the VFD output to a single-phase motor directly. This VFD is designed for three-phase motors.
- Zajistěte správné uzemnění frekvenčního měniče a motoru.
- Avoid touching internal components immediately after power-off, as residual voltage může být přítomno.
- Neprovozujte frekvenční měnič s poškozenými kabely nebo pokud jeasing je otevřené.
- External resistance is not supported. Adjust parameters for similar functionality.
- For heavy-duty motors, consider a higher power VFD.
- Delta (Δ) connection is recommended for the motor.
3. Konec produktuview
The HKS VFD-2200 is a compact and robust variable frequency drive. It features a digital display and a control panel for easy interaction.

Obrázek 3.1: Přední view of the HKS VFD-2200. This image shows the main unit with its digital display, control buttons, and adjustment knob.
3.1 Ovládací panel a displej
The VFD's control panel provides visual feedback and allows for parameter adjustments. It can be detached for remote operation.

Obrázek 3.2: The detachable control panel of the VFD. This feature allows for flexible installation and remote control capabilities.

Obrázek 3.3: Detailní view of the control panel buttons and their functions. This includes RUN/STOP, SET, JOG, REV/FWD, and the adjustment knob, along with indicators for ERROR, FWD, REV, ANALOG, SEGMENT, and PANEL.
| Tlačítko | Popis |
|---|---|
| RUN / STOP | Starts the inverter when idle, stops the inverter when running. |
| STOP/RESET | Stops the inverter if running; resets the inverter if a fault occurs; returns to the parent menu when navigating menus. |
| REV/FWD | Changes the inverter's direction (clockwise/counter-clockwise rotation). Operates during runtime. |
| SOUBOR | Enters the menu setting. In the sub-menu, saves the parameter and moves to the next item. |
| ▲ / ▼ | Menu item selection and sub-item data modification. |
| ◀ / ▶ | Menu item content modification selection or inverter jogging button. |
| Seřizovací knoflík | Controls the output frequency. |
| Indikátor | Popis |
|---|---|
| CHYBA | Indikátor poruchy. |
| FWD | Indikátor otáčení ve směru hodinových ručiček. |
| REV | Anti-clockwise rotation indicator. |
| ANALOGOVÝ | Indikátor frekvence analogového vstupu. |
| SEGMENT | Indikátor vstupní frekvence segmentu. |
| PANEL | Indikátor vstupní frekvence panelu. |
| Digitální LCD | Inverter runtime frequency. If inverter stops, it flashes. The display data is given by "Pn01" data. |
4. Specifikace
| Parametr | Hodnota |
|---|---|
| Číslo modelu | VFD-2200 |
| Moc | 2.2 kW (3 koně) |
| Vstupní objemtage | AC 220V (180-250V) |
| Výstupní objemtage | 220V |
| Vstupní proud | 10A |
| Výstupní proud | 15A |
| Vstupní frekvence | 40-60Hz |
| Výstupní frekvence | 0-400Hz |
| Vstupní fáze | Single-phase or Three-phase |
| Výstupní fáze | Třífázový |
| Hmotnost položky | 2.35 libry |
| Rozměry balení | 7.48 x 7.24 x 5.43 palce |

Obrázek 4.1: Physical dimensions of the HKS VFD-2200, showing approximate measurements of 5.5 inches in height, 4.4 inches in width, and 3.3 inches in depth.
5. Nastavení a zapojení
Proper wiring is critical for the safe and correct operation of the VFD. Ensure all power is off before proceeding.
5.1 Basic Connection Diagram
The VFD supports both single-phase and three-phase 220V input. The output is always three-phase for motor control.

Obrázek 5.1: Simplified wiring diagram showing the connection from a circuit breaker to the VFD (R, S, T terminals) and then from the VFD (U, V, W terminals) to a three-phase motor. This illustrates a typical setup for connecting the VFD to power and a motor.

Obrázek 5.2: Detailed basic connection diagram for the HKS VFD. This schematic shows connections for single-phase 220V (R, T) or three-phase 220V (R, S, T) input, and three-phase output (U, V, W) to the motor. It also illustrates control terminals for FWD/STOP, REV/STOP, RESET, multi-speed inputs, digital frequency up/down, and external analog signal input (0-5V, 0-10V, 0-20mA) for frequency control via an external potentiometer.
- Vstupní výkon (R, S, T): Connect your 220V AC power supply. For single-phase input, connect to R and T terminals. For three-phase input, connect to R, S, and T terminals.
- Výkon motoru (U, V, W): Connect these terminals to your three-phase motor. Ensure the motor is rated for 220V three-phase operation.
- Základy: Always connect the ground terminal of the VFD to a reliable earth ground.
- Ovládací terminály: The VFD provides various control terminals for external start/stop, reverse, reset, multi-speed settings, and analog input for frequency control (e.g., with an external potentiometer). Refer to the detailed wiring diagram (Figure 5.2) for specific connections.
5.2 Initial Parameter Settings
After wiring, it is essential to configure basic parameters. Consult the full parameter list in the comprehensive manual for detailed settings. Common initial settings include:
- PN02: Set maximum output frequency (e.g., 50Hz or 60Hz depending on region).
- PN10: Set motor rated frequency.
- PN12: Set motor rated voltage.
- PN08 & PN09: Adjust acceleration and deceleration times. Default is 10 seconds.
If using an external potentiometer for frequency control, ensure the corresponding analog input parameters are correctly configured.
6. Návod k obsluze
Once the VFD is correctly wired and initial parameters are set, you can begin operation.
6.1 Základní obsluha
- Zapnutí: Apply power to the VFD. The digital display will illuminate.
- Nastavit frekvenci: Use the adjustment knob on the control panel to set the desired output frequency. Alternatively, use the ▲/▼ buttons or an external analog input if configured.
- Spouštěcí motor: Stiskněte tlačítko BĚH button. The FWD or REV indicator will light up, and the motor will start accelerating to the set frequency.
- Změnit směr: Stiskněte tlačítko REV/FWD button during operation to change the motor's rotation direction.
- Zastavení motoru: Stiskněte tlačítko STOP/RESET tlačítko. Motor zpomalí a zastaví.
6.2 Rozšířený provoz
The VFD supports various advanced functions accessible through parameter settings. These include multi-speed operation, PID control, and more. Refer to the detailed parameter manual for specific configurations.
7. Údržba
Pravidelná údržba zajišťuje dlouhou životnost a spolehlivý provoz vašeho frekvenčního měniče.
- Čištění: Periodically clean the VFD's exterior and cooling vents to prevent dust accumulation, which can hinder heat dissipation. Use a soft, dry cloth. Do not use liquid cleaners.
- Chlazení: Ensure adequate airflow around the VFD. The design incorporates multiple holes and sufficient space between components for effective cooling.
- Spojení: Periodically check all wiring connections for tightness and signs of corrosion or damage. Loose connections can lead to poor performance or faults.
- Podmínky prostředí: Operate the VFD within its specified environmental limits (temperature, humidity, vibration).

Obrázek 7.1: Illustration of the VFD's cooling system, showing the internal fan and airflow paths designed to maintain optimal operating temperatures and ensure low noise operation.
8. Řešení problémů
This section addresses common issues and their potential solutions. The VFD is equipped with various protection features that may trigger an error state.
8.1 běžné závady a jejich řešení
- Ochrana proti přetížení: If the motor draws excessive current, the VFD will trip. Check the motor load, ensure the motor is not jammed, and verify VFD power rating matches the motor.
- Přepětítage Protection (DC voltage > 400V): Nastane, pokud vstupní objemtage is too high or during rapid deceleration of a high-inertia load. Check input voltage and consider increasing deceleration time (PN09).
- Nízký objemtage Protection (DC voltage < 200V): Nastane, pokud vstupní objemtage drops below the acceptable range. Check input power supply.
- Ochrana proti zkratu: Indicates a short circuit in the motor or output wiring. Disconnect power and inspect motor and wiring for damage.
- Ochrana proti přehřátí: The VFD's internal temperature is too high. Check for blocked cooling vents, ensure proper ambient temperature, and verify the cooling fan is operational.
- Ochrana proti stání: The motor is unable to rotate or is heavily loaded. Reduce load or check for mechanical issues with the motor.
- Instantaneous Start / Overcurrent Error with External Switch: Some users have reported that when the VFD is set for start/stop by an external switch, the acceleration time parameter (PN08) may be ignored, leading to an instantaneous start and potential overcurrent errors. If this occurs, verify parameter settings and consider using panel control or consulting technical support for advanced configurations.
If a fault occurs, the ERROR indicator will illuminate. Press the STOP/RESET button to clear the fault after addressing the underlying issue.

Obrázek 8.1: Diagram illustrating the various protection features of the HKS VFD, including overload, overvoltage, low-load, fuse, restart, stall, short circuit, and overheat protection.
9. Záruka a podpora
For warranty information and technical support, please contact the seller or manufacturer directly. It is recommended to provide details of your setup, including pictures of the load equipment parameters (e.g., motor nameplate), when seeking assistance.
Optional protection plans may be available for extended coverage. Please refer to your purchase documentation for details.