1. Úvod
This manual provides essential information for the installation, operation, and maintenance of the Cisco Catalyst 9200L C9200L-48T-4G-E 48-Port Data 4x1G Uplink Switch. The Cisco Catalyst 9200L Series switches extend the power of intent-based networking and Catalyst 9000 hardware and software innovation to a broader set of deployments. With its family pedigree, Catalyst 9200L Series switches offer uncompromised simplicity without sacrificing security, always-on quality, and network resiliency.
Please read this manual thoroughly before using the device to ensure proper setup and safe operation. Keep this manual for future reference.
2. Bezpečnostní informace
Dodržujte následující bezpečnostní opatření, abyste předešli zranění a poškození zařízení:
- Elektrická bezpečnost: Ujistěte se, že zdroj napájení odpovídá objtage requirements of the switch. Use only the provided power cord or an approved equivalent. Do not operate the switch with a damaged power cord or plug.
- Základy: Vždy se ujistěte, že je spínač řádně uzemněn, abyste předešli úrazu elektrickým proudem.
- Větrání: Do not block ventilation openings. Ensure adequate airflow around the switch to prevent overheating.
- Prostředí: Operate the switch in a clean, dry environment within the specified temperature and humidity ranges. Avoid exposure to direct sunlight, heat sources, or excessive moisture.
- Zacházení: Handle the switch with care. Avoid dropping or subjecting it to strong impacts.
- Servis: Do not attempt to service the switch yourself. Refer all servicing to qualified service personnel.
3. Obsah balení
Verify that your package contains the following items. If any item is missing or damaged, contact your supplier.
- Cisco Catalyst 9200L C9200L-48T-4G-E Switch
- Napájecí kabel
- Rack-mount Kit (optional, may vary by package)
- Console Cable (optional)
- Dokumentace (Stručný průvodce, Bezpečnostní informace)
4. Fyzický overview
This section describes the front panel components of the Cisco Catalyst 9200L C9200L-48T-4G-E switch.

Obrázek 4.1: Front Panel of Cisco Catalyst 9200L C9200L-48T-4G-E Switch
The image displays the front panel of the Cisco Catalyst 9200L C9200L-48T-4G-E switch. It features 48 RJ45 Ethernet ports for data connectivity, arranged in multiple rows. To the right, there are four 1 Gigabit SFP uplink ports. Various status indicator LEDs are visible above the ports, along with a USB console port and a USB Type-A port. The overall chassis is silver-gray.
4.1 Součásti předního panelu
- 48 portů 10/100/1000BASE-T: These RJ45 ports provide data connectivity for network devices.
- 4 x 1G SFP uplink porty: These ports are used for high-speed connections to other network devices or the core network.
- Stavové LED diody: Indicators for System Status, PoE Status (if applicable), Port Status, and Stack Status. Refer to the LED indicator section for detailed descriptions.
- USB Console Port (Mini-B): Used for local management and configuration via a console cable.
- Port USB typu A: Can be used for external storage or software upgrades.
5. Nastavení
5.1 Montáž do racku (volitelné)
If your package includes a rack-mount kit, follow these steps to install the switch in a standard 19-inch equipment rack:
- Připevněte držáky pro montáž do racku k bokům přepínače pomocí dodaných šroubů.
- Zarovnejte přepínač s sloupky racku a upevněte jej pomocí vhodných šroubů racku.
- Ensure the switch is level and securely fastened.
5.2 Připojení napájení
- Connect the provided power cord to the AC power receptacle on the rear panel of the switch.
- Zapojte druhý konec napájecího kabelu do uzemněné elektrické zásuvky.
- The switch will power on automatically. Observe the System LED for boot-up status.
5.3 Počáteční připojení k síti
- Connect an Ethernet cable from your computer to any of the 10/100/1000BASE-T ports on the switch for initial configuration, or use the console port.
- For console access, connect a console cable from your computer's serial port (or USB-to-serial adapter) to the USB console port on the switch. Configure your terminal emulation software (e.g., PuTTY, Tera Term) with the following settings: 9600 baud, 8 data bits, no parity, 1 stop bit, no flow control.
- Connect network devices (servers, workstations, access points) to the remaining 10/100/1000BASE-T ports using standard Ethernet cables.
- Connect uplink ports (SFP) to your core network or other switches using appropriate transceivers and fiber optic cables, or copper cables if using SFP copper modules.
6. Ovládání přepínače
6.1 Power On and Boot Sequence
Once power is connected, the switch will automatically begin its boot sequence. The System LED will cycle through various states (e.g., amber, green) indicating the boot process. A solid green System LED typically indicates successful boot-up and operational status.
6.2 LED indikátory
LED diody na předním panelu poskytují informace o stavu v reálném čase:
- Systémová LED:
- Svítí zelená: Systém funguje normálně.
- Blikající zelená: System is booting or performing diagnostics.
- Jantar: System fault or error.
- Port Status LEDs (per RJ45 port):
- Svítí zelená: Odkaz zaveden.
- Blikající zelená: Aktivita v přístavu.
- Vypnuto: Žádné spojení ani port nejsou zakázány.
- SFP Uplink Port LEDs: Similar to RJ45 port LEDs, indicating link and activity for the SFP modules.
6.3 Základní konfigurace
Initial configuration is typically performed via the console port or a web interface (if enabled and configured). Refer to the Cisco IOS XE documentation for detailed configuration commands and procedures. Common initial tasks include:
- Setting hostname and basic network parameters (IP address, subnet mask, default gateway).
- Configuring user accounts and passwords.
- Enabling management interfaces (Telnet, SSH, HTTP/HTTPS).
- Configuring VLANs and port assignments.
7. Údržba
7.1 Čištění
Pro udržení optimálního výkonu a prodloužení životnosti přepínače:
- Periodically clean the exterior of the switch with a soft, dry, lint-free cloth.
- Ensure ventilation openings are free from dust and debris. Use compressed air to gently clear dust if necessary, holding the can upright to prevent propellant discharge.
- Nepoužívejte tekuté ani aerosolové čisticí prostředky přímo na spínač.
7.2 aktualizací firmwaru
Pravidelně kontrolujte podporu Cisco website for the latest firmware updates. Keeping your switch's firmware up-to-date ensures optimal performance, security, and access to new features. Follow Cisco's official documentation for firmware upgrade procedures to avoid potential issues.
8. Řešení problémů
Tato část obsahuje řešení běžných problémů, se kterými se můžete setkat.
| Problém | Možná příčina | Řešení |
|---|---|---|
| Spínač se nezapne. | No power, faulty power cord, or power supply issue. |
|
| No link light on a connected port. | Incorrect cable, faulty cable, device not powered on, or port disabled. |
|
| Cannot access switch via console. | Incorrect console cable, wrong terminal settings, or driver issue. |
|
| Network devices not receiving IP addresses. | DHCP server issue, VLAN configuration, or cable problem. |
|
For more advanced troubleshooting, consult the official Cisco documentation or contact Cisco support.
9. Specifikace
| Funkce | Popis |
|---|---|
| Číslo modelu | C9200L-48T-4G-E |
| Značka | Cisco |
| Počet portů | 48 (RJ45) + 4 (Uplink) |
| Rychlost přenosu dat | 4 gigabitů za sekundu (uplink) |
| Typ rozhraní | RJ45, SFP |
| Rozměry produktu | 17.52 x 11.34 x 1.73 palce |
| UPC | 649661944256 |
| Výrobce | CISCO SYSTEMS – PODNIKY |
| Barva | Šedá |
| Kompatibilní zařízení | Desktop (general networking use) |
10. Záruka a podpora
This product is a renewed item. Warranty and support terms may differ from new products. Please refer to the specific warranty information provided by the seller (e.g., Amazon Renewed Guarantee) at the time of purchase.
For technical support related to the Cisco IOS XE software or hardware functionality, it is recommended to consult Cisco's official documentation and support resources. If the product was purchased through a reseller, contact them for initial support inquiries.
Podpora Cisco Webmísto: https://www.cisco.com/c/en/us/support/index.html