1. Konec produktuview
The AOPUTTRIVER AP-570S-APP is a portable, high-performance digital clamp meter designed for troubleshooting electrical problems. It offers a wide range of measurement functions including AC/DC voltage, AC/DC current, resistance, capacitance, frequency, temperature, diode, and continuity testing. This meter features Bluetooth connectivity for mobile phone app integration, allowing for data analysis and remote monitoring.

Image 1.1: AOPUTTRIVER AP-570S-APP Bluetooth Clamp Meter with included test leads, thermocouple, and battery.
2. Bezpečnostní opatření
To ensure safe operation and prevent damage to the meter, please observe the following safety guidelines:
- Vždy dodržujte pokyny uvedené v tomto návodu.
- Nepokoušejte se měřit objemtagproudy nebo napětí překračující specifikované maximální limity.
- Před každým použitím se ujistěte, že jsou měřicí vodiče správně připojeny a v dobrém stavu.
- Do not operate the meter if it appears damaged or if the insulation is compromised.
- Remove the battery if the meter will not be used for an extended period to prevent leakage.
- Při práci s elektrickými obvody pod napětím dbejte zvýšené opatrnosti.
- Před měřením odporu, kapacity nebo diod vždy odpojte napájení obvodu.
3. Product Layout and Components
Familiarize yourself with the various parts of your AP-570S-APP clamp metr:

Image 3.1: Detailed layout of the clamp meter with labels for each component.
- Clamp Čelisti: Opens up to 45mm to enclose conductors for current measurement.
- Oblast detekce NCV: Used for non-contact AC voltage detekce.
- Jaw-Opening Handle: Used to open and close the clamp čelisti.
- Otočný přepínač: Selects measurement functions and ranges.
- Tlačítko HOLD: Press to hold the current reading. Press and hold for more than 2 seconds to activate/deactivate backlight.
- Klávesa SELECT: Used to switch between functions within a rotary switch position (e.g., AC/DC, Diode/Continuity).
- Tlačítko MAX/MIN: Press to display maximum or minimum measured values. Press and hold for 2 seconds to exit.
- Klíč REL: Relative measurement function.
- Hz/Duty Key: On ACV/ACA or Hz range, press to select Frequency or Duty Cycle measurement.
- LCD displej: 6000 counts digital display with full function symbols.
- Vstupní konektor COM: Společný vstup pro měřicí vodiče.
- VΩHzT+ Input Jack: Vstup pro svtage, resistance, frequency, temperature, diode, and capacitance measurements.
4. Nastavení
4.1 Instalace baterie
The AP-570S-APP requires 2 AAA batteries (included). To install or replace batteries:
- Ensure the meter is powered OFF.
- Najděte kryt přihrádky na baterie na zadní straně měřiče.
- Pomocí šroubováku otevřete přihrádku na baterie.
- Vložte 2 baterie typu AAA a dbejte na správnou polaritu (+/-).
- Nasaďte kryt prostoru pro baterie a zajistěte jej šroubem.
If the battery symbol flashes on the display, the battery is low and needs replacement for continued normal operation.
4.2 Bluetooth APP Connection
The meter can connect to a mobile phone via Bluetooth for data measurement and analysis using the 'AiLink' app.

Image 4.1: Visual guide for connecting the meter to the AiLink mobile application.
- Krok 1: Stáhněte si aplikaci. Scan the QR code provided in the product packaging or search for 'AiLink' in the Google Play Store (for Android) or Apple App Store (for iOS). Download and install the application. The app is compatible with iPhone 4S (iOS 7.0 and up) or Android 4.30 systems and up. You can also visit aicare.net.cn/app/ailink/download/ for direct download.
- Step 2: Connect to the Phone. Open the 'AiLink' app. Ensure Bluetooth is enabled on your mobile device. The app should automatically pair with the clamp meter nearby. Press the 'App' button within the application to initiate the connection.
- Krok 3: Spusťte měření. Once connected, you can start measurements, save data, and analyze it through the mobile app.
5. Návod k obsluze
5.1 Obecná obsluha
To begin a measurement, turn the Rotary Switch to the desired function. Use the SELECT button to toggle between AC/DC modes or other sub-functions if available within that range.
5.2 Měřicí funkce
The AP-570S-APP offers the following measurement capabilities:
- AC/DC Voltage: Změřte AC objtagod 6 V do 750 V a stejnosměrného napětítage from 600mV to 1000V. Connect test leads to the VΩHzT+ and COM jacks.
- Střídavý/stejnosměrný proud: Measure AC/DC current from 600A to 1000A using the clamp jaws. Ensure the conductor is centered within the jaws.
- Odpor: Measure resistance from 600Ω to 60MΩ. Connect test leads to the VΩHzT+ and COM jacks.
- Kapacita: Measure capacitance from 6nF to 60mF. Connect test leads to the VΩHzT+ and COM jacks.
- Frekvence: Measure frequency from 9.999Hz to 9.999MHz. Use the Hz/Duty key to switch to frequency measurement.
- Teplota: Measure temperature from -20℃ to 1000℃ (-4℉ to 1832℉) using the included thermocouple. The unit can be switched between ℃ and ℉.
- Diode & Continuity Test: Perform diode and audible continuity tests. Connect test leads to the VΩHzT+ and COM jacks.
- Bezkontaktní AC VoltagDetekce e (NCV): Detekce hlasitosti střídavého proudutage without physical contact. Place the NCV detection area near the conductor. The meter will indicate voltage presence with an audible sound and light.

Image 5.1: Temperature measurement using the thermocouple, demonstrating the ℃/℉ switchable function.

Image 5.2: Non-Contact Voltage (NCV) detection in progress, showing the meter detecting voltage without touching wires.
5.3 Speciální funkce
- Pozastavení dat: Stiskněte tlačítko HOLD pro zmrazení aktuální hodnoty na displeji. Dalším stisknutím jej uvolníte.
- Podsvícení: Press and hold the HOLD button for more than 2 seconds to turn the backlight ON or OFF. This feature aids in reading measurements in dim environments.
- Automatické vypnutí: The meter will automatically power off after a period of inactivity to save battery life. Set the function switch to OFF when finished operating to conserve battery power.

Image 5.3: The meter's display with backlight enabled, improving visibility in dark conditions.
6. Údržba
6.1 Čištění
Otřete c měřičeasing s reklamouamp hadříkem a jemným čisticím prostředkem. Nepoužívejte abrazivní prostředky ani rozpouštědla. Před použitím se ujistěte, že je měřič zcela suchý.
6.2 Skladování
When not in use, store the meter in a dry, cool place, away from direct sunlight and extreme temperatures. Remove the batteries if storing for an extended period.
7. Řešení problémů
- Měřič se nezapne: Zkontrolujte instalaci baterií a ujistěte se, že nejsou vybité. V případě potřeby je vyměňte.
- Indikátor slabé baterie: If the battery symbol flashes on the display, replace the batteries immediately.
- Nepřesná čtení: Ensure test leads are properly connected and the correct function is selected. Verify the circuit is within the meter's specified range.
- Bluetooth App Connectivity Issues: Ensure Bluetooth is enabled on your mobile device and the 'AiLink' app has necessary permissions (e.g., location access). Restart both the meter and the app if connection fails.
- Obecné otázky: If you encounter any issues not covered here, please consult the manufacturer for assistance.
8. Specifikace
| Parametr | Specifikace |
|---|---|
| DC svtage | 600mV - 1000V |
| AC svtage | 6V – 750V |
| Stejnosměrný proud | 600A – 1000A |
| AC proud | 600A – 1000A |
| Odpor | 600Ω – 60MΩ |
| Kapacita | 6nF - 60mF |
| Frekvence | 9.999Hz - 9.999MHz |
| Teplota | -20℃ – 1000℃ / -4℉ – 1832℉ |
| Provozní teplota | 0 to 40℃ (relative humidity <85%) |
| Skladovací teplota | -10 to 50℃ (relative humidity <85%) |
| Guaranteed Precision Temperature | 23±5℃ (relativní vlhkost <70%) |
| Dimenze | 225 (V) × 77 (Š) × 45 (H) mm |
| Hmotnost | Cca. 330 g (včetně baterie) |
| Zdroj napájení | 2 AAA baterie |
| Zobrazit | LCD displej s 6000 číslicemi |
| Speciální funkce | Bluetooth APP Connectivity, NCV, Backlight, Data Hold, Auto Ranging |
9. Záruka a podpora
For any questions regarding the use, maintenance, or troubleshooting of your AOPUTTRIVER AP-570S-APP Bluetooth Clamp Meter, please contact AOPUTTRIVER customer support. We are committed to assisting you with any inquiries you may have.
For more information about AOPUTTRIVER products, please visit the official AOPUTTRIVER Store.