1. Úvod
This manual provides detailed instructions for the installation, operation, and maintenance of the Zurn AquaSense ZER6000AV-HET-TM EZ Gear-Driven 1.28 GPF Exposed Sensor Water Closet Flush Valve. This high-efficiency flush valve is designed for commercial restroom applications, offering reliable, hands-free operation and water conservation.
The ZER-TM Series features a ceramic disc cartridge and motor gear-driven operation for durability and precision. Its 1.28 GPF (Gallons Per Flush) rate contributes to water savings, while the polished chrome-plated finish and quiet diaphragm operation make it suitable for various commercial environments.

Figure 1: Zurn AquaSense ZER6000AV-HET-TM Flush Valve
2. Bezpečnostní informace
Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in property damage, personal injury, or improper product function.
- Před zahájením jakékoli instalace nebo údržby se ujistěte, že je přívod vody uzavřen.
- Během instalace používejte vhodné osobní ochranné prostředky (OOP), jako jsou ochranné brýle a rukavice.
- All plumbing work should comply with local codes and regulations.
- Do not use abrasive cleaners or tools that may damage the chrome finish or internal components.
- Uchovávejte baterie mimo dosah dětí. Zlikvidujte baterie v souladu s místními předpisy.
3. Co je v krabici
Před zahájením instalace ověřte, zda jsou všechny komponenty přítomny:
- Zurn AquaSense ZER6000AV-HET-TM Flush Valve Assembly
- 4 AA baterií (součástí balení)
- Installation Hardware (e.g., vacuum breaker, tailpiece, spud coupling)
- Uživatelská příručka (tento dokument)
4. Konec produktuview
Familiarize yourself with the various views of the Zurn AquaSense ZER6000AV-HET-TM flush valve.

Obrázek 2: Přední strana View

Obrázek 3: Zpět View

Obrázek 4: Strana View (Senzor)

Obrázek 5: Strana View
5. Pokyny k instalaci
Professional installation is recommended. Ensure all necessary tools and materials are available before starting.
5.1 Kontroly před instalací
- Confirm the water supply line is compatible with the flush valve's inlet connection type (Solvent Weld).
- Ensure the water closet (toilet) spud is compatible with the flush valve's outlet connection size (3 Inches).
- Verify that the rough-in dimensions match the requirements for the ZER6000AV-HET-TM model.
5.2 Postup instalace
- Vypněte přívod vody: Locate the main water shut-off valve for the restroom or building and turn it off. Flush the toilet to relieve pressure.
- Remove Existing Flush Valve (if applicable): Carefully disconnect and remove the old flush valve assembly.
- Prepare Inlet and Outlet: Clean and prepare the water supply pipe and the toilet spud for connection.
- Assemble Flush Valve Components: Attach the tailpiece, vacuum breaker, and spud coupling to the main flush valve body as per the diagram provided with the product packaging.
- Připojení k vodovodnímu potrubí: Securely connect the flush valve inlet to the water supply pipe.
- Connect to Toilet Spud: Attach the spud coupling to the toilet spud, ensuring a watertight seal.
- Nainstalujte baterie: Open the battery compartment (typically located on the top cover) and insert the 4 AA batteries, observing correct polarity. Close the compartment securely.
- Zapněte přívod vody: Pomalu otevřete hlavní uzavírací ventil vody. Zkontrolujte těsnost všech spojů.
- Testovací provoz: Allow the sensor to detect presence and initiate a flush. Adjust the sensor range if necessary (refer to the operating instructions).

Figure 6: Flush Valve Installed in a Restroom Setting

Figure 7: Close-up of Installed Flush Valve
6. Návod k obsluze
The Zurn AquaSense ZER6000AV-HET-TM flush valve operates automatically using an infrared (IR) sensor.
6.1 Sensor Operation
- The advanced IR sensor detects presence both forward and downward.
- After a user departs the sensor's detection zone, the valve will initiate a precisely timed 1.28 GPF flush.
- The sensor is designed to prevent false flushes and ensure optimal water usage.
6.2 Ruční ovládání
In case of power failure or for manual flushing, a manual override button is typically located on the flush valve cover. Press this button firmly to initiate a flush.
7. Údržba
Regular maintenance ensures optimal performance and longevity of your Zurn flush valve.
7.1 Čištění
- Clean the exterior of the flush valve with a soft cloth and mild, non-abrasive cleaner.
- Do not use harsh chemicals, abrasive pads, or polishes as they can damage the polished chrome finish.
- Pravidelně otírejte čočku snímače měkkým hadříkemamp cloth to ensure clear detection.
7.2 Výměna baterie
The flush valve is powered by 4 AA batteries, which typically last for 3 years under normal usage. A low battery indicator (if present) will signal when replacement is needed.
- Vypněte přívod vody: Turn off the water supply to the flush valve.
- Přístup k bateriovému prostoru: Locate and open the battery compartment cover, usually on the top or front of the sensor housing.
- Vyměňte baterie: Remove old batteries and insert new 4 AA alkaline batteries, ensuring correct polarity (+/-).
- Bezpečná přihrádka: Bezpečně zavřete kryt bateriového prostoru.
- Obnovení zásobování vodou: Turn the water supply back on and test the flush valve operation.
8. Řešení problémů
Běžné problémy a jejich řešení naleznete v tabulce níže.
| Problém | Možná příčina | Řešení |
|---|---|---|
| No flush when sensor is activated | Dead batteries; Water supply off; Sensor obstruction; Internal valve issue | Replace batteries; Check water supply valve; Clean sensor lens; Contact Zurn support |
| Nepřetržité proplachování | Sensor malfunction; Debris in valve; Diaphragm issue | Clean sensor; Inspect and clean valve components; Replace diaphragm; Contact Zurn support |
| Slabé spláchnutí | Low water pressure; Partially closed stop valve; Clogged diaphragm filter | Check building water pressure; Ensure stop valve is fully open; Clean or replace diaphragm filter |
| Netěsnosti z přípojek | Loose connections; Damaged gaskets/seals | Tighten connections; Replace gaskets/seals |
9. Specifikace
Key technical specifications for the Zurn AquaSense ZER6000AV-HET-TM flush valve:
| Funkce | Specifikace |
|---|---|
| Číslo modelu | ZER6000AV-HET-TM |
| Vyplachovací objem | 1.28 GPF (galonů na spláchnutí) |
| Operace | EZ Gear-Driven, Sensor Activated |
| Materiál | Heavy-duty Brass Body |
| Dokončit | Leštěný Chrome |
| Typ vstupního připojení | Solvent Weld |
| Typ výstupního připojení | NPT |
| Velikost výstupního připojení | 3 palce |
| Zdroj napájení | 4 AA baterií (součástí balení) |
| Životnost baterie | Přibližně 3 let |
| Trvanlivost | Ceramic gear-driven operation withstands over 500,000 cycles |
| Environmentální hodnocení | IP65 rated construction |
| Certifikace | Vyhovuje ADA |
| Rozměry produktu | 8.13 x 9.75 x 16.75 palce |
| Hmotnost položky | 10.9 libry |
10. Záruka a podpora
The Zurn AquaSense ZER6000AV-HET-TM Flush Valve comes with a 3letá omezená záruka od data nákupu. Tato záruka se vztahuje na vady materiálu a zpracování při běžném používání a servisu.
For warranty claims, technical assistance, or to purchase replacement parts, please contact Zurn Industries customer support:
- Webmísto: www.zurn.com
- Služby zákazníkům: Refer to the Zurn webstránky s aktuálními kontaktními informacemi (telefonní čísla, e-mail).
Please have your model number (ZER6000AV-HET-TM) and date of purchase available when contacting support.