1. Konec produktuview
The OONO DIN Rail Mount Terminal Block Distribution Module is designed for efficient and organized electrical wiring distribution in industrial and control applications. This module features an 8x3 position configuration, allowing for the distribution of power from a single inlet to eight distinct output channels, each with three positions (A, B, C).
Mezi klíčové vlastnosti patří:
- DIN rail mount compatibility for easy installation.
- High current and voltage ratings: 30A/300V for the inlet and 20A/300V for each output position.
- Pluggable screw terminal blocks for convenient wiring and maintenance.
- Constructed with high-quality Taiwan fireproof nylon material for durability and safety.

Obrázek 1: Celkově view of the OONO DIN Rail Mount Terminal Block Distribution Module with pluggable terminals.
2. Bezpečnostní informace
Always adhere to local electrical codes and safety regulations when installing or working with this module. Ensure power is disconnected before making any connections or performing maintenance. Only qualified personnel should perform electrical installations.
- Odpojit napájení: Always ensure power is off before installation, wiring, or maintenance.
- Správné nástroje: Používejte izolované nástroje vhodné pro elektrické práce.
- Kompatibilita vodičů: Ensure wire gauges are within the specified range (26-10 AWG for inlet, 28-12 AWG for outlet).
- Zabezpečená připojení: Verify all screw terminals are tightened securely to prevent loose connections and potential hazards.
- Podmínky prostředí: Install in a dry environment, free from excessive dust or corrosive substances.
3. Specifikace
| Specifikace | Hodnota |
|---|---|
| Číslo modelu | MD-D1341T-1 |
| Typ montáže | Montáž na lištu DIN |
| Inlet Current Rating | 30 Amps (per position) |
| Outlet Current Rating | 20 Amps (per position) |
| svtage Hodnocení | 300 voltů |
| Počet kontaktů | 48 (1 inlet x 3 positions + 8 outlets x 3 positions) |
| Rozteč | 7.62 mm / 0.3 palce |
| Inlet Wire Range | 26 AWG ~ 10 AWG / 4mm² |
| Outlet Wire Range | 28 AWG ~ 12 AWG / 2.5mm² |
| Inlet Strip Length | 8 mm |
| Outlet Strip Length | 7 mm |
| Typ šroubu | M3, steel, Cr3+ Zn plated |
| Materiál | Brass (Pin header and Cage), Fireproof Nylon (Carrier) |
| Rozměry (D x Š x V) | Přibližně 163 x 47.8 x 43.2 mm (6.42 x 1.88 x 1.70 palce) |

Figure 2: Dimensional drawing of the terminal block module (size unit: mm).
4. Instalace a nastavení
4.1 Montáž na DIN lištu
- Ensure the DIN rail is securely mounted in your enclosure or panel.
- Align the module's DIN rail clips with the top edge of the DIN rail.
- Press the module firmly downwards until the clips snap onto the DIN rail, securing the module in place.
- To remove, gently pull the release tabs (if present) or pry the bottom edge of the module away from the rail while lifting.

Figure 3: The terminal block module securely mounted on a standard DIN rail.

Obrázek 4: Spodní strana view znázorňující mechanismus montáže na DIN lištu.
4.2 Zapojení kabeláže
The module features one INLET terminal block and eight OUTLET terminal blocks. Each block has three positions labeled A, B, and C. The INLET positions are internally connected to the corresponding A, B, and C positions of all eight OUTLET blocks.
- Připravte dráty: Strip the insulation from the wire ends according to the specified strip lengths: 8mm for INLET wires and 7mm for OUTLET wires. Ensure the wire gauge is within the specified range for each terminal.
- Connect INLET Wires: Loosen the M3 screws on the INLET terminal block. Insert the prepared wires into the A, B, and C positions. Tighten the screws firmly to ensure a secure electrical connection.
- Connect OUTLET Wires: For each of the eight OUTLET channels, loosen the M3 screws on the pluggable terminal blocks. Insert the prepared wires into the A, B, and C positions. Tighten the screws firmly.
- Insert Pluggable Blocks: Once all OUTLET wires are connected to their respective pluggable blocks, carefully insert each pluggable block into its corresponding receptacle on the main distribution module. Ensure they are fully seated.

Figure 5: Internal wiring schematic showing connections from INLET to OUTLET positions.

Obrázek 6: Nahoře view of the module with pluggable terminal blocks detached, showing the base receptacles.
5. Provoz
Once installed and wired correctly, the OONO DIN Rail Mount Terminal Block Distribution Module operates passively by distributing the incoming electrical signals or power from the INLET to the eight OUTLET channels. Each A, B, and C position on the INLET is directly connected to the corresponding A, B, and C position on all OUTLETs.
- svtage a aktuální: Ensure that the total current drawn from any single OUTLET position does not exceed 20 Amps and the total current through any INLET position does not exceed 30 Amps. The maximum operating voltage je 300 voltů.
- Pluggable Design: The pluggable nature of the OUTLET terminal blocks allows for easy disconnection of individual output circuits for testing, maintenance, or replacement without disturbing the main wiring to the module.
6. Údržba
Regular maintenance helps ensure the longevity and reliable operation of the terminal block module.
- Pravidelná prohlídka: Visually inspect the module and all connections periodically for any signs of damage, corrosion, or loose wires.
- Utáhněte spoje: Over time, vibrations or temperature changes can cause screw terminals to loosen. Periodically re-tighten all screw connections to ensure optimal contact.
- Čištění: If necessary, clean the module with a dry, lint-free cloth. Do not use liquid cleaners or solvents. Ensure power is disconnected before cleaning.
- Kontrola prostředí: Ensure the operating environment remains within suitable conditions (e.g., temperature, humidity, absence of corrosive gases).
7. Řešení problémů
If you encounter issues with the terminal block module, consider the following troubleshooting steps:
- Žádný výkon:
- Verify that power is supplied to the INLET terminals.
- Check all INLET and OUTLET wire connections for looseness or improper seating.
- Ensure the pluggable OUTLET blocks are fully inserted into their receptacles.
- Přerušované připojení:
- Znovu utáhněte všechny šroubové svorky.
- Inspect wires for damage or insufficient stripping length.
- Přehřívání:
- Ensure the current draw does not exceed the specified ratings (30A for INLET, 20A for OUTLET).
- Verify wire gauges are appropriate for the current load.
- Check for short circuits in the connected circuits.
- Fyzické poškození:
- If the module or terminals show signs of physical damage (e.g., cracks, burns), replace the unit immediately.
8. Záruka a podpora
This product is manufactured to high-quality standards. For specific warranty information and technical support, please refer to the documentation provided with your purchase or contact OONO customer service through their official channels. Keep your purchase receipt for warranty claims.
Pro další pomoc prosím navštivte OONO Store on Amazon.