Zurn 34-850TXL

Zurn 34-850TXL Lead-Free FNPT Tapped Ball Valve User Manual

Model: 34-850TXL

1. Úvod

This manual provides instructions for the proper installation, operation, and maintenance of the Zurn 34-850TXL Lead-Free FNPT Tapped Ball Valve. This valve is designed for residential, commercial, and industrial applications, suitable for throttling and balancing low-pressure steam, air, water, and non-corrosive gas or oil systems.

Zurn 34-850TXL Lead-Free FNPT Tapped Ball Valve, front view

Obrázek 1: Přední strana view of the Zurn 34-850TXL Lead-Free FNPT Tapped Ball Valve.

2. Bezpečnostní informace

Read all instructions carefully before installation or operation. Failure to follow these instructions may result in property damage, personal injury, or death. Always wear appropriate personal protective equipment (PPE) during installation and maintenance.

  • Ensure the system is depressurized and drained before installing or servicing the valve.
  • Verify compatibility of the valve material with the fluid being handled.
  • Do not exceed the maximum pressure rating of the valve.
  • Instalaci by měl provádět kvalifikovaný personál v souladu s místními předpisy a předpisy.

3. Obsah balení

Balíček by měl obsahovat následující položku:

  • One (1) Zurn 3/4" Tapped Ball Valve (Model 34-850TXL)

4. Specifikace produktu

FunkceDetail
Číslo modelu34-850TXL
ZnačkaZurn
MateriálBrass, Bronze
Vnější povrchBronz
Velikost vstupního připojení0.75 palce
Typ vstupního připojeníPlný přístav
Velikost výstupního připojení0.75 palce
Typ výstupního připojeníFNPT (Female National Pipe Taper)
Počet portů2
Rozměry produktu (D x Š x V)3 x 4 x 4 palce
Hmotnost položky11.29 unce
DodržováníLead-Free Compliant, Specification Met: Steam
Zurn 34-850TXL Ball Valve with model number visible

Obrázek 2: Strana view of the Zurn 34-850TXL valve, showing model markings.

5. Instalace

Follow these steps for proper installation of the Zurn 34-850TXL ball valve:

  1. Příprava: Ensure the system is completely shut off, depressurized, and drained. Clean the pipe threads of any debris.
  2. Těsnicí prostředek na závity: Apply an appropriate thread sealant (e.g., PTFE tape or pipe dope) to the male pipe threads. Ensure the sealant is compatible with the system fluid and valve materials.
  3. Spojení: Thread the valve onto the pipe. Use a wrench on the valve body flats to tighten. Neutahujte příliš, as this can damage the valve or pipe threads. Avoid applying torque to the valve handle.
  4. Orientace: The valve can be installed in any orientation. Ensure the handle has sufficient clearance for full quarter-turn operation.
  5. Tapped Port (if applicable): If utilizing the tapped port, ensure proper connection and sealing of any auxiliary devices (e.g., pressure gauges, drain valves).
  6. Spuštění systému: Slowly repressurize the system and check for leaks at all connections.
Zurn 34-850TXL Ball Valve, showing FNPT inlet

Obrázek 3: View of the valve's FNPT inlet connection.

Zurn 34-850TXL Ball Valve, showing FNPT outlet

Obrázek 4: View of the valve's FNPT outlet connection.

6. Provoz

The Zurn 34-850TXL is a quarter-turn ball valve, meaning it requires a 90-degree rotation of the handle to go from fully open to fully closed, or vice versa.

  • Otevření ventilu: Rotate the handle until it is parallel with the pipeline. This indicates a full port opening, allowing maximum flow.
  • Zavření ventilu: Rotate the handle until it is perpendicular to the pipeline. This indicates the valve is fully closed, stopping flow.
  • Throttling/Balancing: The valve can be partially opened to regulate flow. For precise balancing, specialized balancing valves may be more suitable.

7. Údržba

The Zurn 34-850TXL ball valve is designed for minimal maintenance. Regular inspection is recommended to ensure optimal performance.

  • Inspekce: Periodically check for any signs of leaks around the valve body or connections. Inspect the handle for damage or looseness.
  • Čištění: Keep the exterior of the valve clean. Avoid using harsh chemicals that could damage the bronze finish or internal components.
  • Mazání: The valve is designed with self-lubricating components and typically does not require external lubrication.
  • Opravit: In case of persistent leaks or operational issues, it is recommended to replace the valve. Attempting to repair internal components may void any warranty and could compromise the valve's integrity.

8. Řešení problémů

ProblémMožná příčinaŘešení
Leakage at pipe connectionsImproper thread sealant, insufficient tightening, damaged threads.Depressurize system, reapply thread sealant, retighten connections. If threads are damaged, replace the valve or pipe section.
Leakage from valve body/stemInternal seal failure, manufacturing defect.Vyměňte ventil.
Valve difficult to turnDebris inside valve, worn internal components, corrosion.Attempt to cycle the valve several times. If resistance persists, replace the valve.
Incomplete shut-offDebris preventing full closure, worn ball or seats.Vyměňte ventil.

9. Záruka a podpora

For specific warranty information and technical support regarding your Zurn 34-850TXL Lead-Free FNPT Tapped Ball Valve, please refer to the official Zurn website or contact Zurn customer service directly. Keep your purchase receipt for warranty claims.

Výrobce: Zurn Industries

Webmísto: www.zurn.com (Napřampodkaz, skutečný odkaz se může lišit)