ACR PLB-400

Uživatelská příručka k osobnímu lokátoru ACR ResQLink 400

Model: PLB-400 | Brand: ACR

1. Úvod

The ACR ResQLink 400 is a compact, buoyant, GPS-enabled Personal Locator Beacon (PLB) designed to provide a direct link to rescue services in an emergency. When activated, it transmits a powerful 406 MHz distress signal to the Cospas-Sarsat satellite system, along with your precise GPS location, alerting search and rescue efforts worldwide. This device is intended for use in outdoor emergencies across various activities including hiking, hunting, boating, and fishing.

ACR ResQLink 400 Personal Locator Beacon

Image: The ACR ResQLink 400 Personal Locator Beacon, a compact, bright yellow and clear device.

Person hiking with ACR ResQLink 400 attached to backpack

Image: The ResQLink 400 attached to a backpack during a hike, demonstrating portability.

2. Klíčové vlastnosti

3. Setup and Registration

Before using your ResQLink 400, it is critical to register your beacon with the appropriate national authority. In the United States, this is the National Oceanic and Atmospheric Administration (NOAA). Registration is free and mandatory. It provides search and rescue forces with vital information about you and your vessel/activity, which can significantly aid in a rescue operation.

For detailed activation instructions, please refer to the video below:

Video: ACR ResQlink 400 + 425 Activation Guide. This video demonstrates the steps to activate your Personal Locator Beacon in an emergency.

Initial Registration Steps:

  1. Visit the official beacon registration website for your country (e.g., NOAA for USA).
  2. Locate your beacon's Unique Identifier Number (UIN) or Hex ID, typically found on the device label.
  3. Complete the online registration form with accurate personal and emergency contact information.
  4. Keep your registration information up-to-date, especially if your contact details or emergency contacts change.

4. Operating the ResQLink 400 in an Emergency

The ResQLink 400 is designed for simple, rapid deployment in life-threatening situations. Follow these steps carefully:

  1. Deploy the Antenna: Slide the antenna cover up and extend the antenna fully. Ensure it is positioned at a 90-degree angle to the beacon and has a clear view oblohy pro optimální satelitní příjem.
  2. Activate the Beacon: Press and hold the red "ON" button for approximately 2 seconds until the red LED light begins to flash. The device will start acquiring GPS coordinates and transmitting the distress signal.
  3. Confirm GPS Acquisition: Once GPS coordinates are acquired, the red LED will turn green, indicating a successful position fix. The strobe light will also begin to flash.
  4. Udržet pozici: Leave the beacon in an open area with an unobstructed view of the sky. Do not turn it off until rescue personnel confirm your safety.
Person holding ACR ResQLink 400 on a boat

Image: A person holding the ACR ResQLink 400 Personal Locator Beacon on a boat, demonstrating its use in a marine environment.

5. Self-Test Procedure

Regular self-testing ensures your ResQLink 400 is functioning correctly. Perform a self-test monthly or before any extended trip.

Video: ACR ResQlink 400 + 425 Self-Test Guide. This video provides instructions on how to perform a self-test on your Personal Locator Beacon.

Steps for Self-Test:

  1. Deploy Antenna: Slide the antenna cover up and extend the antenna fully.
  2. Initiate Self-Test: Press and hold the "T" (Test) button for approximately 2 seconds.
  3. Sledujte LED diody: The green LED will flash once, followed by a second green LED flash. If you have the "View" model, the display will confirm "SELF TEST PASS".
  4. Důležitá poznámka: During the self-test, ensure you do not touch the antenna. Holding the antenna can interfere with the test and potentially cause it to fail.

If the self-test fails (e.g., red LED flashes, no display message, or "FAIL" message), consult the troubleshooting section or contact ACR support.

6. Údržba a péče

7. Řešení problémů

ProblémMožná příčinaŘešení
Self-Test Fails (Red LED)Antenna not deployed correctly, low battery, internal fault.Ensure antenna is fully extended and not obstructed. Check battery expiration. If issue persists, contact ACR support.
No GPS Acquisition during activationZabráněno view of sky, device not stationary.Přejděte na otevřené místo s volným view of the sky. Keep the device stationary during activation.
Zařízení se nezapneDepleted or expired battery.Check battery expiration date. Contact ACR support for battery replacement.

8. Specifikace

9. Co je v krabici

10. Záruka a podpora

ACR Electronics, Inc. stands behind the quality and reliability of its products. For specific warranty details, service, or technical support, please refer to the official ACR webwebu nebo se přímo obraťte na jejich zákaznický servis.

Navštivte ACR Store on Amazon pro více informací a nabídku produktů.

11. Důležité bezpečnostní informace

The ACR ResQLink 400 is a critical safety device. It is subject to regulations by various authorities, including Cospas-Sarsat and the FCC. Always ensure your device is properly registered and maintained according to local and international guidelines. This device is intended for emergency use only. False activation can result in penalties.

Právní prohlášení: Cospas-Sarsat, FCC

Související dokumenty - PLB-400

Předview Instalační příručka ACR ResQLink PLB pro záchrannou vestu Atlas 190 UML
Podrobný návod k montáži osobního lokalizačního majáku (PLB) ACR ResQLink na záchrannou vestu Atlas 190 UML, který zajišťuje bezpečnou a správnou funkčnost.
Předview Návod k montáži záchranné vesty Atlas 190 Hammar ACR ResQlink AIS
Podrobný návod k montáži osobního lokátoru (PLB) ACR ResQlink AIS na záchrannou vestu Mustang Survival Atlas 190 Hammar, který zajišťuje správnou a bezpečnou instalaci v nouzových situacích.
Předview Pokyny pro ACR AISLink MOB k nafukovacímu záchrannému prostředkovi ELITE 190
Podrobný návod, jak namontovat zařízení ACR AISLink MOB na nafukovací záchranný prostředek ELITE 190, aby byla zajištěna bezpečná a správná funkce.
Předview ACR Sea Shelter™ 4 Mounting Template and Installation Guide
Download the ACR Sea Shelter™ 4 mounting template (Y1-06-0299 A) with detailed dimensions and critical installation cautions for EPIRB safety.
Předview Návod k montáži a instalaci světlometu ACR RCL-300A
Komplexní návod pro montáž a instalaci systému světlometů ACR RCL-300A, včetně hlavní řídicí jednotky URC-300 a bodového panelu URP-102, s podrobnými pokyny k zapojení a funkcím.
Předview ACR Kelowna Gas Stove Manual: Installation, Operation, and Maintenance
Comprehensive user and installation manual for the ACR Kelowna gas stove (Model 12H, G20 at 20mbar), covering setup, operation, technical specifications, cleaning, maintenance, troubleshooting, error codes, and warranty information.