1. Úvod
This manual provides essential information for the safe and correct installation, operation, and maintenance of the Truma Ignition Safety Valve Set, designed for use with Truma S 3002 and S 5002 heaters. Please read these instructions thoroughly before installation and use to ensure proper function and safety.
2. Bezpečnostní informace
VAROVÁNÍ: Nesprávná instalace, seřízení, úprava, servis nebo údržba může způsobit poškození majetku, zranění nebo smrt. Před instalací nebo servisem tohoto zařízení si důkladně přečtěte pokyny pro instalaci, provoz a údržbu.
- Instalaci a servis musí provádět kvalifikovaný instalační technik, servisní agentura nebo dodavatel plynu.
- Always shut off the gas supply before performing any maintenance or service.
- Při provozu plynových spotřebičů zajistěte dostatečné větrání.
- Check for gas leaks after installation or service using an approved leak detection solution.
- Nepoužívejte otevřený oheň ke kontrole úniku plynu.
3. Obsah balení
Před zahájením instalace ověřte, zda jsou všechny komponenty přítomny a nepoškozené.
- Ignition protection valve
- O-kroužek
- Matice
- Řezací kroužek
- Associated wiring and mounting brackets (as pictured)

Obrázek 1: Components of the Truma Ignition Safety Valve Set. This image displays the main valve assembly with attached wiring, a flexible hose, an O-ring, a nut, a cutting ring, and two metal mounting brackets.
4. Nastavení a instalace
This ignition safety valve set is designed for specific Truma S 3002 and S 5002 heaters. Refer to your heater's primary manual for detailed instructions on accessing the valve area.
- Příprava: Ensure the gas supply to the heater is completely shut off and the system has cooled down. Disconnect any electrical power to the heater.
- Demontáž starého ventilu (pokud je k dispozici): Carefully disconnect the gas lines and electrical connections from the existing safety valve. Note the orientation and connections for proper reassembly.
- Instalace nového ventilu:
- Attach the new ignition safety valve to the heater using the provided mounting brackets. Ensure it is securely fastened.
- Connect the gas inlet and outlet lines. Use the new O-ring, nut, and cutting ring for a secure, leak-free connection. Tighten connections to manufacturer specifications, but do not overtighten.
- Connect the electrical wiring from the valve to the heater's control system. Ensure correct polarity and secure connections.
- Test těsnosti: After installation, slowly turn on the gas supply. Apply an approved gas leak detection solution to all gas connections. Bubbles indicate a leak. If a leak is detected, immediately shut off the gas supply and re-tighten the connection. Repeat the leak test until no bubbles appear.
- Electrical Test: Restore electrical power to the heater and perform a functional test according to the heater's operating instructions.
Poznámka: If you are unsure about any step of the installation process, consult a qualified gas appliance technician.
5. Provoz
The Truma Ignition Safety Valve is an integral component of your Truma S 3002/5002 heater's safety system. It operates automatically to ensure safe gas flow.
- When the heater is switched on and an ignition signal is present, the safety valve opens to allow gas to flow to the burner.
- If the flame extinguishes unexpectedly (e.g., due to wind or gas supply interruption), the safety valve will automatically close the gas supply within a specified timeframe, preventing unburnt gas from accumulating.
- This valve does not require manual operation during normal use. Its function is entirely automatic and safety-critical.
6. Údržba
Regular maintenance of your Truma heater system, including the ignition safety valve, is crucial for safe and efficient operation. While the safety valve itself requires minimal direct user maintenance, periodic checks are recommended.
- Roční kontrola: It is recommended to have your entire Truma heating system, including the gas lines and safety valve, inspected annually by a qualified technician.
- Vizuální kontrola: Periodically inspect the valve and its connections for any signs of corrosion, damage, or loose fittings.
- Čištění: Keep the area around the valve clean and free from dust or debris. Do not use harsh chemicals or abrasive cleaners.
- Výměna součásti: If any part of the safety valve set appears damaged or worn, it must be replaced with genuine Truma spare parts by a qualified technician.
7. Řešení problémů
If your Truma heater is not functioning correctly, and you suspect an issue with the ignition safety valve, consider the following:
| Problém | Možná příčina | Řešení |
|---|---|---|
| Heater does not ignite or repeatedly fails to ignite. | No gas supply, faulty ignition, or safety valve not opening. |
|
| Heater ignites but flame extinguishes quickly. | Insufficient gas pressure, faulty thermocouple/flame sensor, or safety valve closing prematurely. |
|
| Zápach plynu. | Ůnik plynu. |
|
Důležité: Do not attempt repairs on gas components unless you are a qualified and certified technician. Always prioritize safety.
8. Specifikace
- Typ produktu: Ignition Safety Valve Set
- Značka: Truma
- Kompatibilita modelu: Truma S 3002, Truma S 5002 heaters
- Číslo dílu: FRA309492
- Materiál: Plastic (valve body may contain metal components)
- Rozměry (D x Š x V): Přibližně 2.76 x 6.3 x 2.76 palce (7 x 16 x 7 cm)
- Hmotnost položky: Přibližně 14.8 unce (420 g)
- Vnější úprava: Vymalováno
- Velikost vstupního připojení: 1.6E+2 Millimeters (160mm)
- Typ vstupního připojení: Cutting Ring
- Velikost výstupního připojení: 16 milimetrů
- Typ výstupního připojení: Cutting Ring
- Počet portů: 2
- Specifikace splněna: CE
9. Informace o záruce
Specific warranty terms for the Truma Ignition Safety Valve Set are provided by the manufacturer, Truma. Please refer to the warranty documentation included with your original purchase or visit the official Truma webpodrobné informace o záručním krytí, době trvání a postupu pro reklamace naleznete na webu.
Uschovejte si doklad o koupi pro účely záruky.
10. Zákaznická podpora
For technical assistance, spare parts, or service inquiries, please contact Truma customer support or an authorized Truma service center.
You can find contact information and a list of authorized service partners on the official Truma webmísto: www.truma.com
When contacting support, please have your product model number (FRA309492) and purchase details ready.