1. Úvod
This user manual provides comprehensive instructions for the DIGITEN Water Flow Control LCD Display System, including the 1/2" Flow Sensor Meter, 1/2" Solenoid Valve, and 12V Power Adapter. This system is designed for precise quantitative control and monitoring of liquid flow, making it suitable for various industrial and home improvement applications. Please read this manual thoroughly before installation and operation to ensure proper use and longevity of the product.
2. Vlastnosti
- Quantitative Control: The controller automatically shuts off the solenoid valve when the desired flow volume is reached.
- Real-Time Flow Monitoring: Displays the current volume of liquid passing per minute.
- Universal Flow Sensor Compatibility: Works with various Hall effect flow sensors by adjusting the K value.
- Volume Unit Selection: Display measurements in Liters or Gallons.
- Water Meter Functionality: Can be used to accurately measure water volume.
- Adjustable Accuracy: Calibrate precision by fine-tuning the K parameter.
- Monitorování teploty: Includes a temperature sensor to measure liquid temperature.
- Snadno čitelný LCD displej: Clear display of total volume, flow rate, and temperature, with custom icons indicating controller status.
3. Technické specifikace
| Parametr | Specifikace |
|---|---|
| Požadavek na napájení ovladače | 12V DC |
| Vstup napájecího adaptéru | 100-240VAC |
| Výstup napájecího adaptéru | 12VDC, max 2A |
| Přesnost měření | ±1 % |
| Output for Solenoid Valve | 12VDC, max 2A |
| Rozsah snímače teploty | 0-120 °C / 32-212 °F |
| Přesnost snímače teploty | ±1°C / ±1°F (NTC3950, M8 thread) |
| Maximální celkový objem | 999999 G/L |
| Kvantitativní rozsah | 1-9999 G/L |
| Rozsah průtoku | 1-30 l/min |
| Délka kabelu | 1m |
| Provozní teplota | 0-50 °C / 32-122 °F |
| Relativní vlhkost | <85 % |
| Materiál | Plast |
| Velikost vstupního/výstupního připojení | 0.5 palce |
| Typ ventilu | Solenoidový ventil |
| Hmotnost položky | 7.1 unce |
4. Components Included in Packaging

Figure 4.1: All components included in the DIGITEN Water Flow Control System package.
- 1 x DFC15 Controller
- 1 x G1/2" Flow Sensor
- 1 x G1/2" Solenoid Valve
- 1 x AC100-240V Power Adapter
- 1 x snímač teploty
- 1 x Návod k obsluze (tento dokument)

Figure 4.2: The DFC15 controller unit with its attached cables for various connections.

Obrázek 4.3: Detail view of the G1/2 inch flow sensor, responsible for measuring liquid flow.

Obrázek 4.4: Detail view of the G1/2 inch solenoid valve, which controls the liquid flow based on controller signals.

Figure 4.5: The AC100-240V power adapter, providing 12VDC power to the system.
5. Nastavení a instalace
Proper installation is crucial for the accurate and reliable operation of your DIGITEN Water Flow Control System. Follow these steps carefully:

Figure 5.1: Wiring diagram illustrating the connections between the controller, flow sensor, solenoid valve, temperature sensor, and power adapter.
- Montáž ovladače: Choose a suitable location for the DFC15 controller that is easily accessible and protected from direct water exposure.
- Install the Flow Sensor: Integrate the G1/2" flow sensor into your water line. Ensure the flow direction matches the arrow indicated on the sensor body. Use appropriate sealing tape (e.g., Teflon tape) on all threaded connections to prevent leaks.
- Install the Solenoid Valve: Install the G1/2" solenoid valve in the water line, typically downstream of the flow sensor. Pay attention to the flow direction arrow on the valve. Ensure secure and leak-free connections.
- Connect the Flow Sensor to Controller: Connect the flow sensor's signal cable to the designated input on the DFC15 controller. Refer to the wiring diagram (Figure 5.1) for correct pin assignments (VCC, GND, Signal).
- Connect the Solenoid Valve to Controller: Connect the solenoid valve's power wires to the controller's solenoid output terminals. Ensure correct polarity if specified.
- Připojení teplotního senzoru: If using, connect the temperature sensor to its dedicated input on the controller.
- Připojte napájení: Plug the 12VDC power adapter into a standard AC outlet (100-240VAC) and connect its output plug to the DFC15 controller's power input.
- Zkontrolujte připojení: Before applying water pressure, double-check all connections for tightness and correct wiring.
Note on Sealing: Some users have reported that the 1/2" connections may require a generous amount of Teflon tape to ensure a watertight seal, especially under pressure. Apply tape thoroughly to all male threads.
6. Návod k obsluze
The DFC15 controller features an intuitive LCD display and control buttons for easy operation.

Figure 6.1: Front panel of the DFC15 controller showing the LCD display and control buttons (MENU, SET, CLEAR, UP, DOWN, RUN/STOP).
6.1 Základní obsluha
- Zapnutí: Once connected to power, the LCD display will illuminate.
- Informace o displeji: The main screen displays the total volume, real-time flow rate (LPM/GPM), and sensed temperature (°C/°F).
- Tlačítko SPUSTIT/STOP: Stiskněte tlačítko RUN / STOP button to initiate or halt the flow. When running, the solenoid valve will open, allowing liquid to pass.
- Setting Quantitative Flow:
- Stiskněte tlačítko SOUBOR button to enter the quantitative setting mode.
- Použijte UP a DOLŮ arrows to adjust the desired volume.
- Stiskněte SOUBOR znovu pro potvrzení hodnoty.
- Stiskněte RUN / STOP to start the flow. The system will automatically stop when the set volume is reached.
- Clearing Total Volume: Stiskněte tlačítko JASNÝ button to reset the accumulated total volume.
6.2 Advanced Settings (K Value Calibration)
The K value is a calibration factor that allows the controller to accurately measure flow with different sensors. It may need adjustment for optimal accuracy.
- Access K Value Setting: Stiskněte tlačítko MENU button to navigate through settings until you find the K value adjustment.
- Adjust K Value: Použijte UP a DOLŮ arrows to change the K value. A higher K value means the sensor is reporting more pulses per unit of volume, and vice-versa.
- Postup kalibrace:
- Measure a known volume of liquid (e.g., 1 liter or 1 gallon) using a precise measuring container.
- Run the system to dispense this known volume.
- Compare the dispensed volume with the volume displayed on the controller.
- Adjust the K value incrementally until the displayed volume matches the actual dispensed volume. For example, if the controller reads lower than actual, decrease the K value. If it reads higher, increase the K value.
- Uložit nastavení: Stiskněte SOUBOR or MENU (depending on the specific firmware) to save the new K value.
Note on Button Responsiveness: Some users have noted that the controller may require two presses of the RUN/STOP button to initiate operation if it has entered a sleep mode. The first press wakes the unit, and the second initiates the flow.
7. Údržba
Regular maintenance ensures the longevity and optimal performance of your water flow control system.
- Zajistěte bezpečné připojení: Periodically check all threaded connections for leaks and tighten if necessary. Reapply Teflon tape if leaks persist.
- Vyčistěte senzory: If flow readings become erratic, the flow sensor may need cleaning to remove any debris or mineral buildup. Disconnect power and water supply before cleaning.
- Protect the Controller: Ensure the DFC15 controller is kept dry and away from direct sunlight or extreme temperatures.
- Kontrola napájení: Verify that the power adapter is not damaged and is providing stable 12VDC power.
8. Řešení problémů
This section addresses common issues you might encounter with the DIGITEN Water Flow Control System.
| Problém | Možná příčina | Řešení |
|---|---|---|
| Inaccurate Flow/Volume Readings | Incorrect K value calibration; debris in flow sensor; air bubbles in line. | Recalibrate the K value (refer to Section 6.2). Clean the flow sensor. Ensure no air is trapped in the system. |
| Water Leaks at Connections | Insufficient sealing tape; loose connections; damaged threads. | Apply more Teflon tape to male threads. Ensure connections are tightened securely. Inspect threads for damage. |
| Solenoid Valve Not Opening/Closing | No power to valve; faulty wiring; valve stuck; controller issue. | Check power supply to controller and valve connections. Verify wiring according to diagram. Ensure valve is not obstructed. Test controller output. |
| Displej se nerozsvítí | No power; faulty power adapter; damaged controller. | Check power outlet. Test power adapter output. Contact support if controller is unresponsive. |
| Controller Requires Two Button Presses to Start | Controller in sleep mode. | This is normal behavior for some units; the first press wakes the device, the second initiates the action. |
9. Záruka a podpora
DIGITEN stands behind the quality of its products.
9.1 Informace o záruce
The DIGITEN Water Flow Control System comes with a jednoletá záruka covering any manufacturing defects or quality problems from the date of purchase. Please retain your proof of purchase for warranty claims.
9.2 Zákaznická podpora
For technical assistance, troubleshooting, or warranty inquiries, please contact DIGITEN customer support. You can find contact information on the official DIGITEN website or through your purchase platform. When contacting support, please provide your product model number (DFC15FV408) and a detailed description of the issue.
For more information about DIGITEN products, visit the official DIGITEN Store on Amazon.