Uživatelská příručka k hliníkové vložkě AMS 405.57 1 1/2" x 12"

Model: 405.57 | Brand: AMS

Zavedení

This manual provides essential information for the proper use, maintenance, and care of your AMS 405.57 1 1/2" x 12" Aluminum Liner. This liner is designed for use with various 1-1/2" AMS core samplers, facilitating efficient and reliable sampsbírka.

Konec produktuview

AMS 1 1/2 inch by 12 inch aluminum liner

Popis obrázku: A single, cylindrical aluminum tube, approximately 12 inches in length, with an outer diameter of 1 1/2 inches. The surface appears brushed or slightly textured, indicative of aluminum material. Both ends are open, showing the hollow interior of the liner. This image illustrates the primary component of the AMS 405.57 product.

The AMS 405.57 Aluminum Liner is a precision-engineered component for soil and sediment sampling. It features a 1-1/2 inch outer diameter and a 12-inch length. The wall thickness is approximately 0.060 inches, providing a balance of durability and lightweight handling. This liner is specifically designed to integrate seamlessly with compatible AMS core samplers.

Klíčové vlastnosti:

Nastavení

Before using the aluminum liner, ensure you have the appropriate AMS core sampler that is compatible with a 1-1/2 inch liner. The liner is intended to be inserted into the core sampler barrel to collect and retain soil or sediment samples.

  1. Inspect the Liner: Carefully examine the aluminum liner for any signs of damage, dents, or deformities that could affect its performance or fit within the core sampler.
  2. Clean the Liner: Ensure the interior and exterior of the liner are clean and free from debris, dirt, or residues from previous uses. Use a soft cloth and mild detergent if necessary, then rinse thoroughly and dry completely.
  3. Prepare Core Sampler: Refer to your AMS core sampler's manual for specific instructions on preparing it for liner insertion. Ensure the sampler barrel is clean and free of obstructions.
  4. Vložit vložku: Gently slide the aluminum liner into the designated slot or barrel of your 1-1/2" AMS core sampler. Ensure it seats properly and securely. Do not force the liner, as this could cause damage to either the liner or the sampler.
  5. Ověření vhodnosti: Once inserted, confirm that the liner is flush and stable within the core sampler, ready for samplingové operace.

Návod k obsluze

The aluminum liner functions as a disposable or reusable sleeve within a core sampler to preserve the integrity of collected samples. Its operation is directly tied to the use of the core sampler itself.

  1. Attach Core Sampler: Assemble your AMS core sampler with the aluminum liner installed, following the sampler's specific instructions.
  2. Proveďte Sampling: Use the core sampler as directed by its manual to collect the desired soil or sediment sample. The liner will fill with the sample as the sampler penetrates the ground.
  3. Retrieve Sampler: Carefully extract the core sampler from the ground.
  4. Odstraňte vložku: Once the core sampler is retrieved, gently remove the aluminum liner containing the sample. This may involve detaching the sampler's cutting tip or other components as per your sampler's design.
  5. Seal Sampten: Pokud sample is to be transported or stored, cap both ends of the liner immediately to prevent sample loss, contamination, or disturbance. Use appropriate end caps or sealing methods.
  6. Label Liner: Clearly label the liner with all necessary sample identification information (e.g., date, time, location, depth, project ID).

Poznámka: Always refer to the specific operating instructions of your AMS core sampler for detailed sampling procedures. The aluminum liner is a passive component designed to hold the sample.

Údržba

Proper maintenance extends the life of your aluminum liner, especially if intended for multiple uses, and ensures sample integrita.

Odstraňování problémů

This section addresses common issues that may arise during the use of your aluminum liner.

ProblémMožná příčinaŘešení
Liner does not fit into core sampler.
  • Incorrect liner size.
  • Liner is dented or deformed.
  • Core sampler barrel is obstructed or damaged.
  • Verify liner dimensions (1 1/2" OD) against sampler specifications.
  • Inspect liner for damage; replace if necessary.
  • Clean and inspect core sampler barrel.
Sample is difficult to extract from liner.
  • Compacted sample.
  • Rough interior surface of liner (due to wear or damage).
  • Použijte vhodné sample extrusion tools.
  • Consider replacing the liner if interior surface is compromised.
Liner gets stuck in core sampler.
  • Liner or sampler barrel is dirty.
  • Liner is slightly deformed.
  • Excessive force during insertion.
  • Clean both components thoroughly.
  • Inspect liner for subtle deformities; replace if needed.
  • Always insert gently.

Specifikace

AtributDetail
Číslo modelu405.57
Vnější průměr1 1/2 palce (přibližně 3.81 cm)
Délka12 palců (přibližně 30.48 cm)
Tloušťka stěnyApproximately 0.060 inches (approx. 1.52 mm)
MateriálHliník
Přibližná hmotnost1 libra (přibližně 0.45 kg)
Rozměry balení14 x 4 x 4 palce
VýrobceAMS Incorporated
Země původuSpojené státy
Datum první dostupnosti12. prosince 2017

Záruka a podpora

Specific warranty information for the AMS 405.57 Aluminum Liner is not provided in this document. For details regarding product warranty, technical support, or replacement parts, please contact AMS Incorporated directly through their official webstránky nebo kanály zákaznických služeb.

Výrobce: AMS Incorporated

Please refer to the manufacturer's official resources for the most current support information.

Související dokumenty - 405.57

Předview Manuál k zkušební sadě adaptérové ​​desky ams AS5600L
Tato příručka poskytuje komplexní informace o adaptérové ​​desce ams AS5600L-WL_EK_AB, včetně obsahu sady, popisu desky, montážních pokynů, podrobností o zapojení pinů, provozu v režimu I2C, schémat zapojení hardwaru, rozvržení desky plošných spojů a informací o objednání.
Předview Uživatelská příručka k 14bitovému rotačnímu snímači polohy ams AS5048
Tato uživatelská příručka poskytuje podrobné informace o snímači polohy ams AS5048, 14bitovém rotačním snímači polohy s digitálním úhlem a PWM výstupem. Zahrnuje adaptérovou desku AS5048, montáž, zapojení pinů, operační obvody (SPI, Daisy Chain) a kódování firmwaru, např.ampsoubory a hardwarová schémata. Nezbytné pro inženýry, kteří tento senzor integrují do svých systémů.
Předview Manuál k vyhodnocovací sadě adaptérové ​​desky ams AS5048
Tato příručka podrobně popisuje adaptérovou desku ams AS5048 (AS5048-EK-AB), vyhodnocovací sadu pro magnetický snímač polohy AS5048. Zahrnuje hardware, provozní režimy (SPI, I2C), software, např.amples, and contact information for ams AG.
Předview Manuál k vyhodnocovací sadě adaptérové ​​desky ams AS5048
Uživatelská příručka pro zkušební sadu adaptérové ​​desky ams AS5048 (AS5048-EK-AB) s podrobným popisem jejích funkcí, zapojení pinů, montáže, provozních případů (režimy SPI), schémat hardwaru, rozvržení desky plošných spojů a kontaktních informací.
Předview Návod k obsluze nástěnných hodin AMS
Návod k obsluze nástěnných hodin AMS, zahrnující instalaci baterií, výměnu a obecné použití v několika jazycích.
Předview Uživatelská příručka TSL2521 EVM: Vyhodnocovací sada senzoru okolního světla
Uživatelská příručka pro EVM ams TSL2521, která podrobně popisuje jeho vlastnosti jako vysoce citlivého senzoru okolního světla se selektivní detekcí blikání a rychlým...ampZařízení pro použití za OLED displejem nebo jako pomocné zařízení pro kameru. Zahrnuje popis hardwaru a softwaru, informace o nastavení a právní informace.