Watts LF26A

Watts LF26A Water Pressure Regulator Valve User Manual

Model: LF26A

Zavedení

This manual provides essential information for the proper installation, operation, and maintenance of your Watts LF26A Water Pressure Regulator Valve. Please read this manual thoroughly before installation and keep it for future reference. This valve is designed to reduce incoming water pressure to a safe and functional level for residential and light commercial applications, protecting plumbing systems and fixtures from high pressure damage.

Konec produktuview a funkce

The Watts LF26A is a high-quality water pressure regulator valve engineered for reliable performance and durability. Key features include:

Watts LF26A Water Pressure Regulator Valve

Figure 1: Watts LF26A Water Pressure Regulator Valve. This image displays the valve's brass body, the FIP threaded connections on the side, and the pressure adjustment screw located at the top of the brown housing.

Bezpečnostní informace

Během instalace a údržby vždy dodržujte následující bezpečnostní opatření:

Instalace

Kontrolní seznam před instalací:

Kroky instalace:

  1. Uzavření přívodu vody: Najděte hlavní uzávěr vody pro váš dům a uzavřete ho.
  2. Vypouštěcí systém: Otevřete kohoutek v nejnižším bodě systému, abyste vypustili vodu a uvolnili tlak.
  3. Vyberte umístění: Install the pressure regulator valve in an accessible location, typically after the main shut-off valve and before any branch lines. Ensure there is sufficient space for future maintenance.
  4. Příprava připojení: Apply appropriate thread sealant (Teflon tape or pipe dope) to the male threads of the pipes connecting to the valve.
  5. Instalace ventilu: Orient the valve according to the flow arrow cast on its body. The arrow must point in the direction of water flow. Thread the valve onto the pipes, tightening securely with pipe wrenches. Avoid overtightening.
  6. Install Pressure Gauge (Recommended): For accurate pressure monitoring, install a pressure gauge downstream of the regulator.
  7. Obnovení zásobování vodou: Pomalu otevřete hlavní uzavírací ventil vody. Zkontrolujte těsnost všech spojů.
  8. Čistit vzduch: Open faucets throughout the system to purge air until water flows smoothly.

Operace

The Watts LF26A valve is factory preset to a nominal pressure. Adjustment may be necessary to achieve the desired system pressure.

Nastavení výstupního tlaku:

  1. Ensure a pressure gauge is installed downstream of the valve for accurate readings.
  2. Na zvýšení the outlet pressure, turn the adjustment screw (located on top of the valve) ve směru hodinových ručiček.
  3. Na pokles the outlet pressure, turn the adjustment screw proti směru hodinových ručiček.
  4. Make small adjustments (e.g., quarter turns) and observe the pressure gauge. Allow the system pressure to stabilize after each adjustment.
  5. Once the desired pressure is set, ensure the locknut (if present) is tightened to secure the setting.

The adjustable pressure range for this model is 1 to 25 psi.

Údržba

Regular maintenance helps ensure the longevity and optimal performance of your pressure regulator valve.

Odstraňování problémů

If you experience issues with your Watts LF26A pressure regulator valve, refer to the following common problems and solutions:

ProblémMožná příčinaŘešení
No pressure reduction or high outlet pressure.Valve set too high; debris in valve; worn internal components.Adjust pressure setting counter-clockwise; flush system; consult professional for repair/replacement.
Low or fluctuating outlet pressure.Valve set too low; insufficient inlet pressure; debris in valve; worn internal components.Adjust pressure setting clockwise; check main water supply pressure; flush system; consult professional.
Water leaking from valve body or connections.Loose connections; damaged threads; faulty seals/gaskets; cracked valve body.Tighten connections; re-apply thread sealant; replace seals/gaskets; replace valve if cracked.
No water flow through valve.Valve completely closed; significant debris blockage; incorrect installation (e.g., backward).Check adjustment setting; flush system; verify flow arrow direction; consult professional.

For issues not listed or if solutions do not resolve the problem, it is recommended to contact a qualified plumbing professional or Watts customer support.

Specifikace

AtributHodnota
Číslo modeluLF26A
Materiál tělaBezolovnatá mosaz
Velikost vstupu3/8 palce
Velikost výstupu3/8 palce
Typ připojeníFIP (Female Iron Pipe)
Rozsah nastavení tlaku1 až 25 psi
Maximální vstupní tlak300 psi
Maximální teplota140 °F (60 °C)
Rozměry produktu (D x Š x V)2.3 x 2.3 x 5.1 palce
Hmotnost1 libra
AplikaceVoda
CertifikaceSchváleno NSF
VýrobceCAI - WATTS

Záruka a podpora

Warranty information for the Watts LF26A Water Pressure Regulator Valve is typically provided with the product packaging or can be obtained directly from the manufacturer, Watts. Please refer to the official Watts website or contact their customer service for detailed warranty terms and conditions.

For technical support, replacement parts, or further assistance, please contact Watts customer service or visit their official website. When contacting support, please have your product model number (LF26A) and purchase details readily available.

Watts Official Webmísto: www.watts.com

Související dokumenty - LF26A

Předview Návod k instalaci a údržbě redukčního ventilu vody Watts řady LFN45B
Komplexní průvodce instalací, údržbou a řešením problémů s redukčním ventilem vody Watts řady LFN45B. Zahrnuje bezpečnostní varování, postupy nastavení a informace o záruce.
Předview Redukční ventil vody WATTS LFN45B - Instalační a údržbářský manuál
Komplexní průvodce instalací, provozem a řešením problémů s redukčním ventilem vody WATTS LFN45B. Zahrnuje bezpečnostní varování, pokyny k instalaci, postupy nastavení a tipy pro řešení problémů s vodovodními systémy.
Předview Watts LF1L, LF1XL, LF10L, LF100XL Temperature and Pressure Relief Valves - Technical Specification
Detailed technical specification for Watts Series LF1L, LF1XL, LF10L, and LF100XL Lead Free Temperature and Pressure Relief Valves, including features, specifications, dimensions, and safety warnings.
Předview Instalační příručka pro dodatečné připojení sady pro zaplavovací senzory Watts BMS
Tato příručka obsahuje podrobné pokyny k instalaci sady pro dodatečnou montáž připojovací sady pro senzor záplav Watts BMS (model IS-RFK-FS-ReliefValve-BMS). Zahrnuje komponenty sady, požadavky, přípravu, kroky instalace, schémata zapojení a informace o záruce pro monitorování výtlačných potrubí pojistného ventilu.
Předview Instalace a údržba redukčních ventilů vody Watts N55B-M1 a LFN55B-M1
Podrobný návod k instalaci, údržbě a řešení problémů s redukčními ventily Watts N55B-M1 a LFN55B-M1, včetně schémat a informací o záruce.
Předview Redukční ventil Watts s hydraulickou zpětnou funkcí - nerezová řada
Technický konecview kombinovaného redukčního a zpětného ventilu Watts ACV s podrobným popisem jeho provozu, pokynů pro instalaci a seznamu souvisejících modelů regulačních ventilů.