1. Úvod
The ARKRAY GLUCOCARD Expression Control Solution Level 1 is designed to verify the accuracy and proper functioning of your GLUCOCARD Expression Glucose Meter and compatible Blood Glucose Test Strips. Regular use of this control solution helps ensure that your glucose monitoring system provides reliable results.
2. Konec produktuview
This control solution contains a known concentration of glucose, allowing you to perform a quality control check on your glucose meter and test strips. It is an essential component for maintaining the integrity of your blood glucose monitoring process.
Klíčové vlastnosti:
- Ověření přesnosti: Designed to confirm the precision of the GLUCOCARD Expression Meter and Blood Glucose Test Strips.
- Standardized Glucose Level: Contains a known glucose concentration for reliable reference.
- Snadná aplikace: A single drop is applied to a test strip, similar to a blood sample.
- Routine Testing Recommended: Advised for use when opening new test strip vials, after meter drops, or when results seem inconsistent.
- Convenient Vial: Each package includes one 2.5 ml vial of Level 1 control solution.

This image displays the ARKRAY GLUCOCARD Expression Control Solution Level 1. It shows a small white vial with a green cap, labeled 'GLUCOCARD Expression Level 1 Control Solution', alongside its white cardboard packaging box. The box also features the 'GLUCOCARD Expression Control Solution Level 1 - 2.5ml' branding and indicates 'Suitable for self-testing'.
3. Nastavení
Before performing a control test, ensure you have your GLUCOCARD Expression Glucose Meter, compatible test strips, and the control solution ready.
- Check Expiration Date: Verify that both the control solution and test strips are within their expiration dates. Do not use expired products.
- Shake Vial Gently: Before each use, gently shake the control solution vial to ensure the contents are thoroughly mixed. This helps maintain an even glucose concentration for accurate testing.

This image shows a hand holding the GLUCOCARD Expression Control Solution vial, with a drop being applied to a test strip. In the background, the GLUCOCARD Expression meter is visible, emphasizing the process of verifying the system's accuracy.
4. Operating Instructions: Performing a Control Test
Follow these steps to perform a control test using your GLUCOCARD Expression Control Solution Level 1:
- Vložte testovací proužek: Insert a new GLUCOCARD Expression Test Strip into your glucose meter according to your meter's instructions. The meter should turn on automatically.
- Aplikujte kontrolní roztok: Hold the control solution vial upside down and gently squeeze it to dispense a small drop onto the designated sample area of the test strip. Do not apply directly to the meter.
- Wait for Result: The meter will begin the test and display the result after a short period.
- Compare Results: Compare the displayed result with the control range printed on your test strip vial or in your meter's user manual. The result should fall within this specified range.

This image illustrates the three easy steps for performing a control solution test. Step 1 shows a hand gently shaking the control solution vial. Step 2 shows a drop of control solution being applied to a test strip. Step 3 shows a GLUCOCARD glucose meter displaying a result, with the control solution vial and test strip vial in the background, indicating comparison to the expected range.
5. Údržba
Skladování:
- Store the control solution at room temperature, away from direct sunlight and heat.
- Keep the cap tightly closed when not in use to prevent contamination and evaporation.
- Kontrolní roztok nechlazujte ani nezmrazujte.
Vypršení platnosti:
- Note the expiration date printed on the vial and packaging. Discard the solution after this date.
- Once opened, the control solution typically has a limited shelf life (e.g., 90 days). Refer to the specific instructions on the vial or packaging for the exact duration.
6. Řešení problémů
If your control test results fall outside the expected range, consider the following:
- Check Expiration Dates: Ensure both the control solution and test strips are not expired.
- Správné skladování: Verify that the control solution has been stored correctly (e.g., not exposed to extreme temperatures).
- Vial Shaking: Confirm the control solution vial was gently shaken before use.
- Technika aplikace: Ensure the drop of control solution was applied correctly to the test strip.
- Test Strip Integrity: Use a new test strip from an unopened or recently opened vial.
- Meter Malfunction: If issues persist after re-testing with a new strip and solution, your meter may require servicing. Refer to your glucose meter's user manual or contact customer support.
7. Specifikace
| Funkce | Detail |
|---|---|
| Značka | GLUCOCARD Expression |
| Model | Control Solution Level 1 |
| Počet jednotek | 1.00 Počet |
| Objem | 2.5 ml |
| Speciální funkce | Snadné použití |
| Výrobce | archray |
| První dostupný termín | 4. května 2016 |
8. Důležité bezpečnostní informace
Statements regarding dietary supplements have not been evaluated by the FDA and are not intended to diagnose, treat, cure, or prevent any disease or health condition. This control solution is for in vitro diagnostic use only. Do not ingest. Keep out of reach of children.
9. Záruka a podpora
Specific warranty information for the ARKRAY GLUCOCARD Expression Control Solution Level 1 is not provided in the available product details. For detailed warranty terms or customer support, please refer to the documentation included with your GLUCOCARD Expression Glucose Meter or contact ARKRAY customer service directly.
10. Oficiální produktová videa
Do této příručky nejsou k dispozici žádná oficiální produktová videa od prodejce, která by bylo možné vložit.