1. Úvod
This manual provides essential information for the safe and effective installation, operation, and maintenance of your Genteq OEM ICP Heil Tempstar Blower Motor, Model HQ1013341EM / 1013341. Please read this manual thoroughly before attempting any procedures to ensure proper function and to prevent potential hazards.
2. Bezpečnostní informace
Vždy dodržujte následující bezpečnostní opatření:
- Elektrické nebezpečí: Disconnect all power to the furnace or air handler unit before installing, servicing, or removing the motor. Failure to do so can result in severe injury or death.
- Kvalifikovaný personál: Installation and servicing should only be performed by a qualified HVAC technician or electrician.
- Osobní ochranné prostředky: Během instalace a údržby používejte vhodné osobní ochranné prostředky (OOP), včetně ochranných brýlí a rukavic.
- Správné zapojení: Ujistěte se, že všechna zapojení elektroinstalace splňují místní a národní elektrotechnické předpisy.
- Vybíjení kondenzátoru: If replacing a capacitor, ensure it is properly discharged before handling to avoid electrical shock.
3. Konec produktuview
The Genteq OEM ICP Heil Tempstar Blower Motor is a 4-speed furnace blower motor designed for various heating and cooling applications. It is a direct replacement for ICP/Heil/Tempstar part # 1013341 (also HQ1013341EM) and Emerson Part # K55HXJEW-9056.

An image showing the Genteq OEM ICP Heil Tempstar Blower Motor. The motor is dark gray with a silver fan end, featuring a shaft extending from the center. Various colored wires (green, red, blue, orange, brown, black, white) are visible, connected to the motor housing. A ruler is partially visible on the left and bottom, indicating the motor's approximate dimensions.
4. Specifikace
| Funkce | Specifikace |
|---|---|
| Číslo modelu | HQ1013341EM / 1013341 |
| koňská síla (HP) | 1/2 HP (0.5 HP) |
| svtage | 115V |
| Rychlost | 1050 ot./min (4stupňový) |
| Motor Diameter (Frame) | 5 5/8 inches (Frame 48Y) |
| Délka hřídele | 4 palců |
| Required Capacitor | 7.5 MFD |
| Výrobce | ICP / Heil / Tempstar (OEM by Genteq) |
5. Instalace (Nastavení)
Installation of this blower motor should only be performed by a qualified technician. Incorrect installation can lead to equipment damage, electrical shock, or fire.
- Odpojení napájení: Ensure all electrical power to the furnace or air handler unit is completely disconnected at the main breaker. Verify with a voltage tester.
- Přístupový motor: Open the access panels to the blower compartment.
- Odpojit kabeláž: Carefully label and disconnect all wires from the old motor and its capacitor. Note the color coding for each speed setting.
- Demontáž starého motoru: Remove the mounting bolts or straps securing the old motor. Slide the blower wheel off the motor shaft.
- Instalace nového motoru: Slide the blower wheel onto the shaft of the new Genteq motor. Secure the blower wheel in place.
- Montáž nového motoru: Secure the new motor using the existing mounting hardware. Ensure it is firmly in place and properly aligned.
- Připojení kabeláže: Reconnect the wires to the new motor and the new 7.5 MFD capacitor according to the labels made during disconnection. Ensure all connections are secure.
- Ověření rotace: Before closing the access panels, temporarily restore power and briefly test the motor to ensure it rotates in the correct direction. If not, consult the wiring diagram for your specific furnace model to reverse rotation if necessary (often by swapping specific wires or a dedicated reversing switch).
- Obnovit napájení: Once installation is complete and verified, close all access panels and restore power to the unit.
6. Provoz
This blower motor is designed to operate within a furnace or air handler system, circulating air through the ductwork. Its operation is controlled by the thermostat and the furnace control board, which dictate when the motor should run and at which speed (if applicable for multi-speed models).
- The motor will engage when the thermostat calls for heating or cooling, or for continuous fan operation.
- The 4-speed capability allows the furnace control board to select the appropriate airflow for different operational modes (e.g., heating, cooling, continuous fan).
7. Údržba
Pravidelná údržba pomáhá zajistit dlouhou životnost a efektivní provoz motoru ventilátoru. Před prováděním jakékoli údržby vždy odpojte napájení.
- Čištění ventilátoru: Ročně kontrolujte a čistěte kolo ventilátoru. Prach a nečistoty usazené na kole mohou snižovat proudění vzduchu a zatěžovat motor.
- Kontrola motoru: Check the motor for any signs of wear, such as unusual noises, vibrations, or overheating. Ensure all wiring connections remain secure.
- Mazání: This motor is typically designed with sealed bearings and does not require periodic lubrication. Refer to your furnace manufacturer's guidelines for specific lubrication requirements, if any.
- Výměna vzduchového filtru: Regularly replace or clean your furnace's air filter. A dirty filter restricts airflow, causing the blower motor to work harder and potentially overheat.
8. Řešení problémů
If you experience issues with your blower motor, consider the following common problems and solutions. For complex issues, contact a qualified technician.
- Motor se nestartuje:
- Check if power is supplied to the unit.
- Zkontrolujte, zda nejsou kabelové spoje uvolněné nebo poškozené.
- Test the capacitor. A faulty capacitor is a common cause of motor failure to start.
- Check for obstructions in the blower wheel.
- Motor Making Loud Noises:
- Inspect the blower wheel for debris or imbalance.
- Check motor mounts for looseness.
- Listen for bearing noise, which may indicate motor wear.
- Přehřátí motoru:
- Ensure adequate airflow by checking and replacing the air filter.
- Clean the blower wheel if it is dirty.
- Verify the motor is receiving the correct voltage.
- Slabé proudění vzduchu:
- Check and replace the air filter.
- Clean the blower wheel.
- Ensure the motor is running at the correct speed for the operating mode.
9. Informace o záruce
Specific warranty details for this OEM replacement part are typically provided by the seller or the original equipment manufacturer (ICP / Heil / Tempstar). Please refer to your purchase documentation or contact the vendor for information regarding warranty coverage and terms.
10. Zákaznická podpora
For technical assistance, troubleshooting beyond the scope of this manual, or inquiries about replacement parts, please contact the authorized distributor or a qualified HVAC service professional.