GVS SPR451

GVS Elipse P100 Dust Half Mask Respirator

Model: SPR451

1. Úvod

The GVS Elipse P100 Dust Half Mask Respirator is designed to provide personal respiratory protection against dust and fumes. Its compact and lightweight design ensures comfort and a full range of vision, making it suitable for various industrial and safety applications. This manual provides essential information for the proper use, maintenance, and care of your respirator.

GVS Elipse P100 Dust Half Mask Respirator, front view

Obrázek 1: Přední strana view of the GVS Elipse P100 Respirator.

Video 1: Konecview of Elipse respirators by GVS, highlighting key features and benefits.

2. Nastavení a montáž

Proper fitting is crucial for effective respiratory protection. Follow these steps to correctly set up and wear your GVS Elipse P100 Respirator:

  1. Inspect the Respirator: Before each use, check the mask body, straps, and filters for any signs of damage, cracks, or wear. Ensure the filters are securely attached.
  2. Nastavení hlavových popruhů: Hold the respirator with one hand and pull the head straps over your head with the other. Position the mask over your nose and mouth. The top strap should rest on the crown of your head, and the neck strap should rest around your neck below your ears.
  3. Tighten Straps: Pull the ends of the straps to tighten the mask until it feels secure but comfortable. Do not overtighten. The mask should fit snugly against your face without gaps.
  4. Perform a Seal Check:
    • Positive Pressure Check: Place the palm of your hand over the exhalation valve cover (front center of the mask) and gently exhale. The mask should slightly bulge outwards, and you should feel no air leaking from the edges.
    • Negative Pressure Check: Place the palms of your hands over the filter covers on both sides of the mask and gently inhale. The mask should pull inward towards your face, and you should feel no air leaking from the edges.
    If you detect any leaks during the seal check, readjust the straps and repeat the check. If leaks persist, the mask may be damaged or incorrectly sized.
GVS Elipse P100 Dust Half Mask Respirator, back view with straps

Obrázek 2: Zpět view of the respirator showing adjustable straps.

Video 2: An unboxing and fitting demonstration of the GVS Elipse P100 Respirator.

3. Návod k obsluze

Once properly fitted, the GVS Elipse P100 Respirator provides effective protection in environments containing dust and fumes. It is recommended for use in situations involving micro-organisms, marble, gypsum, titanium oxide, rock wool, wood, detergents, and various dusts that can cause lung disease, including asbestos, bauxite, coal, silica, and iron.

The mask's compact design allows for a full range of vision and does not interfere with other personal protective equipment (PPE) such as eye or ear protection. Its low breathing resistance minimizes user fatigue during extended periods of use.

Worker wearing GVS Elipse P100 Respirator while drilling into concrete

Figure 3: Worker using the respirator during drilling, demonstrating compatibility with safety glasses.

Video 3: Demonstrates the comfort and lightweight nature of the mask during use.

Video 4: Emphasizes the importance of wearing a respirator for protection in dusty environments.

4. Údržba

Regular maintenance ensures the longevity and effectiveness of your respirator. Filters should be replaced when breathing resistance becomes noticeably high or when odors are detected.

4.1 Výměna filtru

  1. Remove Used Filters: Gently twist and pull the filter covers to detach them from the mask body. Remove the old filter cartridges.
  2. Vložit nové filtry: Align the new filter cartridges with the openings on the mask body and push them firmly into place until they click. Ensure a secure fit.
  3. Reattach Covers: Place the filter covers back over the new filters and twist to lock them into position.

Video 5: Detailed instructions on how to remove and replace the Elipse P100 filters.

4.2 Čištění a skladování

5. Řešení problémů

If you encounter issues with your GVS Elipse P100 Respirator, consider the following:

6. Specifikace

FunkceDetail
Číslo modeluSPR451
SchváleníNIOSH Approval number: P100 TC-84A-6949 (Meets 42CFR84 requirements)
MateriálThermoplastic Elastomers (TPE)
BarvaModrý
VelikostSmall/Medium (Elipse comes in 2 sizes)
Rozměry produktu5 x 4 x 4 palce
Hmotnost6.4 unce
Země původuSpojené království

7. Záruka a podpora

For detailed warranty information and support, please refer to the official GVS user manual available in PDF format. Please note that no returns are allowed on this product.

Oficiální uživatelská příručka (PDF): Stáhnout zde

Související dokumenty - SPR451

Předview GVS Elipse Low Profile Pokyny pro uživatele kombinovaného respirátoru proti plynům a částicím
Komplexní návod k použití pro GVS Elipse low profile combined gas and particulate safety respirator. Covers applications, filter types, fitting, cleaning, maintenance, storage, warnings, limitations, and service life. Essential guide for occupational safety.
Předview Uživatelská příručka k aplikaci GVS Smart V1.4
Uživatelská příručka k aplikaci GVS Smart APP V1.4, která podrobně popisuje, jak ovládat a spravovat zařízení KNX a chytrá domácí zařízení třetích stran, nastavovat scény, integrovat hlasové asistenty a autorizovat služby třetích stran, jako je SONOS.
Předview Uživatelská příručka k serveru GVS Gem Series Z10 pro chytrou domácnost (A-IS03)
Uživatelská příručka pro server GVS Gem Series Z10 pro chytrou domácnost (model A-IS03) s podrobným popisem jeho funkcí, instalace a provozu pro systémy interkomů a ovládání chytré domácnosti v budovách.
Předview Uživatelská příručka k bráně GVS K-BUS KNX pro RS485/RS232 V1.8
Tato uživatelská příručka poskytuje komplexní technické podrobnosti, pokyny k instalaci a programování pro bránu GVS K-BUS KNX pro RS485/RS232 (V1.8). Naučte se, jak integrovat zařízení Modbus, RS485 a RS232 se systémy řízení domácností a budov KNX.
Předview GVS K-BUS KNX Gateway for Tuya ZigBee V2.1 User Manual
This user manual provides detailed technical information, installation, and programming guidance for the GVS K-BUS KNX Gateway for Tuya ZigBee V2.1, enabling seamless integration between KNX and Tuya ZigBee smart home systems.
Předview K-BUS KNX Gateway for IR V1.4 User Manual
Comprehensive user manual for the GVS K-BUS KNX Gateway for IR V1.4, detailing specifications, installation, configuration, and communication objects for both Flush mounted (BTIRF-02/00.2) and Ceiling (BTIRC-01/00.2) models. This guide covers parameter settings within ETS and application examples for home and building automation.