1. Konec produktuview
The ResMed SlimLine Replacement Tubing is designed to provide a comfortable and efficient continuous positive airway pressure (CPAP) therapy experience. This lightweight and flexible tubing is compatible with ResMed Air10 and S9 series machines, ensuring a reliable connection for your respiratory care needs.
- Lehký design: The SlimLine Non-Heated Tubing is sleek and light for a more comfortable CPAP experience.
- Compatibility Assured: This CPAP accessory seamlessly fits ResMed Air10 and S9 machines, ensuring a reliable connection.
- Slim & Flexible: Engineered for space-saving, the slim profile of this CPAP tubing offers greater flexibility and convenience.
- Durable CPAP Supplies: Constructed to be long-lasting, the authentic ResMed brand SlimLine Air Tubing is a dependable component of your CPAP equipment.

Image 1: ResMed Official Logo.

Image 2: The ResMed SlimLine Replacement Tubing, coiled for storage.
2. Nastavení a instalace
Follow these steps to correctly install your ResMed SlimLine Replacement Tubing:
- Odpojení starých trubek: Gently pull the old tubing straight out from the air outlet of your CPAP machine.
- Inspect New Tubing: Ensure the new SlimLine tubing is free from any damage or obstructions.
- Připojení ke stroji: Locate the end of the new tubing with the small chip or slot. Align this chip with the corresponding slot on the air outlet of your ResMed Air10 or S9 machine. Push the tubing in firmly until it is flush and secure.
- Connect to Mask: Attach the other end of the tubing to your CPAP mask. Different mask types may have varying connection mechanisms; ensure a secure fit according to your mask's instructions.

Image 3: ResMed SlimLine Tubing connected to a CPAP machine.
3. Návod k obsluze
Once the SlimLine tubing is securely connected to your CPAP machine and mask, you can begin your therapy. Refer to your specific ResMed CPAP machine's user manual for detailed operating instructions, including how to start and stop therapy, adjust settings, and monitor your progress.
- Ensure all connections are tight before starting therapy to prevent air leaks.
- Position the tubing to avoid kinks or obstructions that could impede airflow.
- If using a humidifier, ensure the water chamber is filled to the appropriate level.
4. Údržba a čištění
Regular cleaning of your SlimLine tubing is essential for hygiene and optimal performance. Follow these general guidelines:
- Denní úklid: Disconnect the tubing from your machine and mask. Wash the tubing in warm water with a mild soap. Rinse thoroughly with clean water.
- Sušení: Hang the tubing in a clean, dry place away from direct sunlight to air dry completely before reattaching. Ensure no water remains inside the tubing.
- Inspekce: Regularly inspect the tubing for any signs of wear, tears, or damage. Replace the tubing if any damage is observed to maintain effective therapy.
- Nahrazení: It is recommended to replace CPAP tubing every 3-6 months, or as advised by your healthcare provider or equipment manufacturer, to ensure optimal hygiene and performance.
5. Řešení problémů
If you encounter issues with your SlimLine tubing, consider the following:
- Úniky vzduchu: Check all connections between the tubing, machine, and mask. Ensure they are securely fitted. Inspect the tubing for any visible holes or cracks.
- Snížený průtok vzduchu: Ensure the tubing is not kinked or obstructed. Check if the tubing is clean and free from debris.
- Condensation (Rainout): If you experience water buildup in the tubing, consider using a heated humidifier with a heated tube (if your machine supports it and you have the appropriate heated tubing), or a tubing wrap/cover to insulate the air.
- Neobvyklé zvuky: Check for loose connections or damage to the tubing.
If problems persist, consult your healthcare provider or the ResMed customer support.
6. Specifikace
| Funkce | Detail |
|---|---|
| Rozměry produktu | 12.28 x 10.08 x 2.36 palce; 3.53 unce |
| Výrobce | ResMed |
| ASIN | B00YFVG9EG |
| Datum první dostupnosti | 28. května 2015 |
7. Bezpečnostní informace
Important Safety Warning Regarding Magnets:
Udržujte magnety masky v bezpečné vzdálenosti alespoň 6 mm od implantátů nebo lékařských zařízení, které mohou být nepříznivě ovlivněny magnetickým rušením. Toto varování se týká vás nebo kohokoli, kdo je v těsném fyzickém kontaktu s vaší maskou. Magnety jsou v rámu a spodních sponách pokrývky hlavy, se silou magnetického pole až 150 mT. Při nošení se spojí, aby masku zajistily, ale během spánku se mohou nechtěně oddělit.
Právní prohlášení:
Masky s magnetickými součástmi jsou kontraindikovány pro použití pacienty, kde oni nebo kdokoli v blízkém fyzickém kontaktu při používání masky mají následující:
- Aktivní lékařské implantáty, které interagují s magnety (tj. kardiostimulátory, implantabilní kardioverter defibrilátory (ICD), neurostimulátory, zkraty mozkomíšního moku (CSF), inzulínové/infuzní pumpy)
- Kovové implantáty/předměty obsahující feromagnetický materiál (tj. svorky aneuryzmatu/zařízení narušující průtok, embolické cívky, stenty, chlopně, elektrody, implantáty pro obnovení sluchu nebo rovnováhy pomocí implantovaných magnetů, oční implantáty, kovové třísky v oku)
8. Záruka a podpora
For warranty information and customer support, please refer to the documentation provided with your original ResMed CPAP machine or visit the official ResMed webUschovejte si doklad o koupi pro případné reklamace.