Hunter ICD600

Hunter Sprinkler ICD600 6-Station Decoder User Manual

Model: ICD600

Značka: Hunter

Konec produktuview

The Hunter ICD600 is a 6-station decoder designed for use with Hunter's ACC controller, integrating advanced features with the benefits of a two-wire decoder system.

Klíčové vlastnosti:

Hunter ICD600 6-Station Decoder with multiple colored wires extending from the top.

Image: The Hunter ICD600 6-Station Decoder, a black rectangular unit with various colored wires (red, blue, black, white, yellow, green) emerging from its top, indicating its electrical connections.

Nastavení a instalace

Proper installation is crucial for the optimal performance and longevity of your ICD600 decoder. Always ensure power is disconnected before beginning any wiring.

Wiring the Decoder:

  1. Identify Wire Paths: The ICD600 supports up to 6 wire paths. Plan your irrigation zones and corresponding wire runs from the ACC controller.
  2. Connect Two-Wire Path: Connect the two-wire path from the ACC controller to the designated terminals on the ICD600 decoder. Ensure a secure, waterproof connection using the provided wire path connectors.
  3. Connect Solenoid Wires: Connect the solenoid wires from each irrigation valve to the corresponding station terminals on the decoder. Observe polarity if specified by the valve manufacturer, though decoders typically manage this internally.
  4. Připojení zemnícího vodiče: Connect the included ground wire from the decoder to a suitable earth ground point to utilize the internal surge suppression. This is vital for protecting the unit from electrical surges.
  5. Master Valve/Pump Start: If using a master valve or pump, connect its wires to the designated master valve/pump output terminals on the decoder. These outputs can be assigned to specific decoders via the controller programming.
  6. Sensor Decoder (Optional): If using a sensor decoder with Flow and Click inputs, connect these as per the sensor's instructions to the appropriate terminals.

Programming the Decoder:

The ICD600 decoders are field programmable. This can typically be done using the ACC controller's interface or with the optional ICD-HP wireless handheld programmer.

Návod k obsluze

Once installed and programmed, the ICD600 decoder operates seamlessly with your Hunter ACC controller. All irrigation scheduling and manual operations are managed through the main controller.

Normální provoz:

Pokročilé funkce:

For detailed instructions on programming irrigation schedules, manual station operation, and advanced controller settings, please refer to the Hunter ACC Controller User Manual.

Údržba

The Hunter ICD600 decoder is designed for durability and requires minimal maintenance. However, periodic checks can help ensure long-term reliable operation.

Odstraňování problémů

If you encounter issues with your ICD600 decoder or irrigation system, consider the following common troubleshooting steps:

ProblémMožná příčinaŘešení
Station not activating
  • Incorrect programming on ACC controller.
  • Loose or corroded wire connection to decoder or valve.
  • Damaged decoder or solenoid.
  • Insufficient power to the two-wire path.
  • Verify station assignment and programming on the ACC controller.
  • Check all wire connections for tightness and corrosion. Repair or replace as needed.
  • Test the solenoid for continuity. If faulty, replace the solenoid. If decoder is suspected, use ICD-HP programmer for diagnostics or consult Hunter support.
  • Ensure the ACC controller is receiving adequate power and its output is functioning correctly.
System reports communication error
  • Break in the two-wire path.
  • Short circuit on the two-wire path.
  • Faulty decoder.
  • Inspect the entire length of the two-wire path for cuts or damage.
  • Check for shorts, especially at splice points or where wires might be pinched.
  • Isolate decoders one by one to identify a faulty unit.
Surge suppression issues
  • Improper or missing ground wire connection.
  • Extreme electrical surge.
  • Ensure the ground wire is securely connected to a proper earth ground.
  • If the unit was exposed to a significant surge, it might be damaged and require replacement.

For more complex issues or if the above steps do not resolve the problem, contact Hunter technical support or a certified irrigation professional.

Specifikace

AtributHodnota
Číslo modeluICD600
Rozměry produktu5 x 7 x 10 palce
Hmotnost položky1.15 libry
Decoder Station Sizes Available1, 2, 4, 6
Max Distance to Decoder (14 AWG wire)10,000 stop
Max Distance to Decoder (12 AWG wire)15,000 stop
Max Recommended Distance (Decoder to Solenoid)150 stop
PřepětíInternal (ground wire included)
Number of Wire Paths6
VýrobceStandard Plumbing Supply-LG

Informace o záruce

Hunter Industries products are manufactured to the highest quality standards and are backed by a limited warranty. Specific warranty terms and conditions, including duration and coverage, are typically provided with the product packaging or can be found on the official Hunter Industries webmísto.

Uschovejte si prosím doklad o koupi pro uplatnění záruky.

Zákaznická podpora

For technical assistance, product inquiries, or troubleshooting beyond the scope of this manual, please contact Hunter Industries customer support.