1. Úvod
The Mitech MT160 is an advanced ultrasonic thickness gauge designed for precise measurement of material thickness. It utilizes ultrasonic waves to determine the thickness of various materials, primarily steel, within a range of 0.75mm to 300mm. This manual provides detailed instructions for the proper setup, operation, maintenance, and troubleshooting of your MT160 device to ensure accurate and reliable performance.
2. Bezpečnostní informace
Please read and understand all safety instructions before operating the Mitech MT160. Failure to follow these instructions may result in injury or damage to the device.
- Nepokoušejte se zařízení rozebírat ani upravovat. Veškerý servis svěřte kvalifikovanému personálu.
- Use only the specified battery type (2 x AA, 1.5V alkaline batteries).
- Nevystavujte zařízení extrémním teplotám, vlhkosti nebo přímému slunečnímu záření.
- Keep the probe and device clean and free from contaminants.
- Ensure proper coupling agent is used for accurate measurements.
3. Obsah balení
Verify that all items listed below are present in your Mitech MT160 package:
- Mitech MT160 Main Unit
- Ultrasonic Probe (Transducer) with cable
- Coupling Agent Bottle
- Tvrdé přepravní pouzdro
- Uživatelská příručka
- Certifikát produktu
- Záruční list

Obrázek 3.1: The Mitech MT160 Ultrasonic Thickness Gauge and its standard accessories, including the probe, coupling agent, and documentation, neatly organized within its protective hard carrying case.

Obrázek 3.2: Detailní záběr view of the ultrasonic probe (transducer) with its connecting cable, an essential component for thickness measurement with the MT160 gauge.

Obrázek 3.3: The included documentation: User's Manual, Product Certificate, and Guarantee Card, providing essential information and warranty details for the MT160 device.
4. Zařízení skončiloview
4.1 Přední panel

Obrázek 4.1: The front panel of the Mitech MT160, featuring the LCD display and various control buttons for operation and settings.
The front panel includes the following key components:
- LCD displej: Shows measurement readings, settings, and status indicators.
- Tlačítko napájení (červený kruh): Zapíná nebo vypíná zařízení.
- SCAN Button (Green Up Arrow): Activates scan mode for continuous measurements.
- PRB Button: Likely for probe selection or settings.
- Tlačítko KALIBRACE: Used for calibration procedures.
- IN/MM Button: Toggles between Imperial (inches) and Metric (millimeters) units.
- ALRM Button (Green Down Arrow): Likely for alarm settings or memory functions.
- Tlačítka se šipkami: For navigation and adjusting values.
4.2 Zadní panel

Obrázek 4.2: The rear panel of the Mitech MT160, displaying the battery compartment cover, product label with specifications, and serial number.
Zadní panel obsahuje:
- Přihrádka na baterie: Houses two AA 1.5V batteries.
- Štítek produktu: Provides essential information such as 'ULTRASONIC THICKNESS GAUGE', 'CE' marking, 'RANGE: 0.75-300mm', and 'POWER: 2 x 1.5V'.
- Sériové číslo (S/N): Unique identifier for the device.
4.3 Strana View

Obrázek 4.3: Strana view of the Mitech MT160, illustrating the two ports for connecting the ultrasonic probe.
The side of the device includes:
- Probe Connection Ports: Two ports for securely attaching the ultrasonic probe cable.
5. Nastavení
5.1 Instalace baterie
- Vyhledejte přihrádku na baterii na zadní straně zařízení.
- Posuňte kryt přihrádky na baterie dolů a otevřete jej.
- Insert two AA 1.5V alkaline batteries, ensuring correct polarity (+/-).
- Nasaďte zpět kryt prostoru pro baterie a posuňte jej nahoru, dokud nezacvakne na místo.
5.2 Připojení sondy
- Identify the two probe connection ports on the side of the MT160 unit.
- Connect the two plugs from the ultrasonic probe cable into these ports. Ensure a firm connection.
6. Provoz
6.1 Zapnutí/vypnutí
Stiskněte tlačítko red circular button once to power on the device. To power off, press and hold the same button until the display turns off. The device also features auto sleep and auto power off functions to conserve battery life.
6.2 Základní měření
- Ensure the probe is connected and the device is powered on.
- Apply a small amount of coupling agent to the surface of the material to be measured. This eliminates air gaps between the probe and the material, which would interfere with ultrasonic wave transmission.
- Place the probe firmly and flatly onto the prepared surface.
- The LCD display will show the thickness reading. The coupling status indicator will confirm proper contact.
- Remove the probe from the surface after the reading stabilizes.
6.3 Kalibrace
Calibration is crucial for accurate measurements. The MT160 allows for calibration using a known thickness or by measuring sound speed.
- Stiskněte tlačítko CAL tlačítko pro vstup do kalibračního režimu.
- Follow the on-screen prompts to calibrate using a material of known thickness or by inputting the sound velocity.
- Confirm the calibration settings.
6.4 Výběr jednotky
Stiskněte tlačítko IN/MM button to toggle between Metric (millimeters) and Imperial (inches) units for your measurements.
6.5 Režim skenování
For continuous measurement and to find the minimum thickness over an area, use the Scan Mode.
- Stiskněte tlačítko SKENOVAT button to activate Scan Mode.
- Move the probe across the surface. The device will continuously update the display with readings (ten per second).
- Stiskněte tlačítko SKENOVAT button again to exit Scan Mode.
6.6 Funkce paměti
The MT160 can store up to 20 files, with each file containing up to 99 values.
- Use the designated memory button (often indicated by a folder icon or similar) to save readings.
- Navigate through stored files and values using the arrow buttons.
6.7 Indikátory
- Coupling Status Indicator: Displays the quality of contact between the probe and the material. A stable indicator means good coupling.
- Remaining Battery Indicator: Shows the current battery level in real-time.
7. Údržba
7.1 Čištění
- After each use, wipe the probe and the device with a soft, dry cloth to remove any coupling agent residue or dirt.
- Do not use abrasive cleaners or solvents, as these can damage the device's surface or display.
7.2 Skladování
- Store the MT160 in its hard carrying case when not in use to protect it from dust, moisture, and physical damage.
- Pokud skladujete po delší dobu, vyjměte baterie, abyste zabránili vytečení.
8. Řešení problémů
If you encounter issues with your Mitech MT160, refer to the following common problems and solutions:
| Problém | Možná příčina | Řešení |
|---|---|---|
| Zařízení se nezapne | Vybité nebo nesprávně nainstalované baterie | Replace batteries with new AA 1.5V alkaline batteries, ensuring correct polarity. |
| Žádné nebo nestabilní čtení | Poor coupling, no coupling agent, incorrect probe placement, or material properties | Apply sufficient coupling agent. Ensure probe is flat and firm on the surface. Check if the material is suitable for ultrasonic measurement. |
| Nepřesné údaje | Device not calibrated, incorrect sound velocity setting, or surface condition | Perform calibration using a known thickness. Verify sound velocity setting. Ensure the measurement surface is clean and smooth. |
| Displej je tlumený nebo bliká | Slabá baterie | Vyměňte baterie. |
If the problem persists after attempting these solutions, please contact Mitech customer support for further assistance.
9. Specifikace
The following are the technical specifications for the Mitech MT160 Ultrasonic Thickness Gauge:
- Zobrazit: 4.5 digits LCD with EL backlight
- Rozsah měření: 0.75~300mm (in Steel)
- Sound Velocity Range: 1000 až 9999 m/s
- Rezoluce: 0.1/0.01mm selectable
- Přesnost: ±(0.5%Thickness + 0.04)mm, dependent on materials and conditions
- jednotky: Metric/Imperial unit selectable
- Rychlost měření: 4 readings/second (single point), 10 readings/second (Scan Mode)
- Paměť: Až do 20 files (max 99 values per file)
- Zdroj napájení: Two “AA” size, 1.5 Volt alkaline batteries
- Provozní doba: Approximately 100 hours (EL backlight off)
- Sdělení: Sériový port RS232
- Rozměry obrysu: 150 × 74 × 32 mm
- Hmotnost: 245g (bez baterií)
10. Záruka a podpora
The Mitech MT160 Ultrasonic Thickness Gauge comes with a Guarantee Card included in the package. Please refer to this card for specific warranty terms and conditions, including the warranty period and details on how to obtain service.
For technical support, service, or inquiries regarding your Mitech MT160, please contact the manufacturer or your authorized dealer. Ensure you have your product model number (MT160) and serial number ready when contacting support.