1. Úvod

This manual provides essential information for the proper installation, operation, and maintenance of your Watts 1 LFU5B-LP-Z3 1-inch Water Pressure Regulator Valve. Please read these instructions thoroughly before installation and retain this manual for future reference. This valve is designed to reduce incoming water pressure to a safe and functional level for residential and commercial plumbing systems, protecting fixtures and appliances from high pressure damage.

2. Bezpečnostní informace

  • Always wear appropriate personal protective equipment (PPE) such as safety glasses and gloves during installation and maintenance.
  • Ensure the main water supply is turned off and the system is depressurized before beginning any work on the valve.
  • If you are not experienced with plumbing installations, it is recommended to consult a qualified professional.
  • Do not exceed the maximum operating pressure or temperature specified for this valve.
  • Ujistěte se, že jsou všechna spojení řádně utěsněna, aby se zabránilo únikům.

3. Konec produktuview

The Watts 1 LFU5B-LP-Z3 is a high-quality, lead-free brass water pressure regulator valve designed for durability and reliable performance. It features a 1-inch inlet and outlet size with FNPT Union x FNPT connection types, making it suitable for various water applications.

Watts 1 LFU5B-LP-Z3 1-Inch Water Pressure Regulator Valve

Obrázek 1: Watts 1 LFU5B-LP-Z3 1-Inch Water Pressure Regulator Valve. This image displays the brass body of the valve, including the inlet and outlet connections, and the adjustment screw at the top for pressure setting.

Klíčové vlastnosti:

  • Materiál těla: Bezolovnatá mosaz
  • Aplikace: Voda
  • Max. Tlak: 300 psi
  • Max. Teplota: 160 stupňů F
  • Pressure Adjustment Range: 10 až 35 psi
  • Typ připojení: FNPT Union x FNPT
  • Velikost vstupu/výstupu: 1 palců
  • standardy: ASSE 1003, ANSI A112.26.2, CSA B356, UPC

4. Specifikace

SpecifikaceHodnota
Číslo modelu1 LFU5B-LP-Z3
Materiál tělaBezolovnatá mosaz
AplikaceVoda
Velikost vstupu1 palců
Velikost výstupu1 palců
Typ připojeníFNPT Union x FNPT
Rozsah nastavení tlaku10 až 35 psi
Maximální teplota160 °F (71 °C)
Maximální tlak300 psi
Délka6-3/4 palce
Výška7-3/8 palce
Hmotnost položky5.9 unce
Normy splněnyASSE 1003, ANSI A112.26.2, CSA B356, UPC

5. Instalace

Proper installation is crucial for the optimal performance and longevity of your pressure regulator valve. It is recommended that installation be performed by a licensed plumber.

Kroky instalace:

  1. Vypněte přívod vody: Locate the main water shut-off valve for your property and turn it off.
  2. Systém odtlakování: Open a faucet at the lowest point in your system to drain water and relieve pressure.
  3. Vyberte umístění: Install the regulator on the main water supply line after the main shut-off valve and before any branch lines. Ensure there is sufficient space for future maintenance.
  4. Orientační ventil: The valve has an arrow indicating the direction of water flow. Install the valve so the arrow points in the direction of water flow into your property.
  5. Vytvořte spojení: Use appropriate plumbing practices to connect the 1-inch FNPT Union x FNPT ends of the regulator to your plumbing system. Apply thread sealant (e.g., PTFE tape or pipe dope) to all threaded connections. Tighten securely but do not overtighten.
  6. Install Pressure Gauge (Optional but Recommended): Install a pressure gauge downstream of the regulator to monitor the regulated pressure.
  7. Obnovení zásobování vodou: Slowly open the main water shut-off valve. Check for leaks at all connections.
  8. Čistit vzduch: Open faucets throughout the property to purge air from the system until water flows smoothly.

6. Operation and Pressure Adjustment

The Watts 1 LFU5B-LP-Z3 valve comes factory-set to a nominal pressure, but it can be adjusted within its specified range (10 to 35 psi) to meet your specific needs.

Nastavení výstupního tlaku:

  1. Ensure Water Flow: It is best to adjust the pressure while water is flowing at a low rate (e.g., a partially open faucet) to get an accurate reading.
  2. Locate Adjustment Screw: The pressure adjustment screw is located at the top of the valve.
  3. Decrease Pressure: Otočte seřizovacím šroubem proti směru hodinových ručiček to decrease the outlet pressure.
  4. Increase Pressure: Otočte seřizovacím šroubem ve směru hodinových ručiček to increase the outlet pressure.
  5. Monitorovací tlak: Use a pressure gauge installed downstream of the regulator to monitor the outlet pressure as you make adjustments.
  6. Test and Verify: After adjustment, close all faucets and observe the static pressure on the gauge. Open a faucet again to verify the dynamic pressure. Repeat adjustments as necessary until the desired pressure is achieved.

7. Údržba

Regular inspection and maintenance can extend the life of your pressure regulator valve and ensure consistent performance.

  • Roční kontrola: Annually check the valve for any signs of leaks, corrosion, or damage.
  • Kontrola tlaku: Periodically check the outlet pressure with a gauge to ensure it remains at the desired setting. Fluctuations may indicate internal wear.
  • Čištění: If the water supply contains sediment, the internal screen (if applicable) may need cleaning. This typically requires shutting off the water, depressurizing the system, and disassembling the lower portion of the valve. Refer to a qualified plumber for this procedure.
  • Náhradní díly: Use only genuine Watts replacement parts if internal components need to be replaced.

8. Řešení problémů

This section addresses common issues you might encounter with your water pressure regulator valve.

Běžné problémy a řešení:

  • No Pressure Reduction:
    • Příčina: Ventil nainstalován obráceně. Řešení: Check flow arrow and reinstall correctly.
    • Příčina: Debris lodged in valve. Řešení: Disassemble and clean valve internals (professional recommended).
    • Příčina: Diaphragm or seat worn out. Řešení: Replace internal components or the entire valve.
  • Low Water Pressure (downstream):
    • Příčina: Regulátor nastavený příliš nízko. Řešení: Adjust pressure setting clockwise to increase.
    • Příčina: Partially clogged valve. Řešení: Inspect and clean internal components.
  • Water Hammer or Chattering Noise:
    • Příčina: Excessive flow velocity or worn components. Řešení: Ensure proper sizing; inspect and replace worn parts if necessary.
  • Leaks from Valve Body:
    • Příčina: Uvolněná spojení. Řešení: Tighten connections (ensure water is off first).
    • Příčina: Poškozené O-kroužky nebo těsnění. Řešení: Replace seals (professional recommended).
    • Příčina: Prasklé pouzdro. Řešení: Replace the entire valve.

If troubleshooting steps do not resolve the issue, contact a qualified plumbing professional or Watts customer support.

9. Informace o záruce

Watts products are manufactured to high-quality standards. For specific warranty terms and conditions applicable to the 1 LFU5B-LP-Z3 Water Pressure Regulator Valve, please refer to the official Watts website or the warranty documentation included with your purchase. Generally, Watts provides a limited warranty against defects in materials and workmanship under normal use and service.

10. Podpora

For technical assistance, replacement parts, or further inquiries regarding your Watts 1 LFU5B-LP-Z3 Water Pressure Regulator Valve, please contact Watts customer support through their official webwebu nebo kontaktních informací uvedených na obalu produktu.

Watts is a registered trademark. All rights reserved.

Související dokumenty - 1 LFU5B-LP-Z3

Předview Watts LF25AUB-Z3 Series Water Pressure Reducing Valve Installation Instructions
Comprehensive installation guide for the Watts LF25AUB-Z3 Series Water Pressure Reducing Valve, detailing safety precautions, installation methods (typical, series, parallel), adjustment procedures, repair kits, and troubleshooting tips. Includes textual descriptions of diagrams and parts.
Předview Watts LFN45B Series Water Pressure Reducing Valve Installation and Maintenance Guide
Comprehensive guide for installing, maintaining, and troubleshooting the Watts LFN45B Series water pressure reducing valve. Includes safety warnings, adjustment procedures, and warranty information.
Předview WATTS LFN45B Water Pressure Reducing Valve - Installation and Maintenance Manual
Comprehensive guide for installing, operating, and troubleshooting the WATTS LFN45B Water Pressure Reducing Valve. Includes safety warnings, installation instructions, adjustment procedures, and problem-solving tips for plumbing systems.
Předview Watts Series LF909 Reduced Pressure Zone Assemblies - Technical Specification
Detailed technical specifications for Watts Series LF909 Reduced Pressure Zone Assemblies, including features, operation, dimensions, weights, and capacity. Designed for potable water cross-connection control.
Předview Watts N55B-M1 and LFN55B-M1 Water Pressure Reducing Valve Installation and Maintenance
Detailed installation, maintenance, and troubleshooting guide for Watts N55B-M1 and LFN55B-M1 Water Pressure Reducing Valves, including diagrams and warranty information.
Předview Watts Pressure Reducing Valve with Hydraulic Check Feature - Stainless Series
Technický konecview of the Watts ACV Combination Pressure Reducing and Check Valve, detailing its operation, installation guidelines, and a list of related control valve models.