Eaton CHFCAF120

Eaton CHFCAF120 Single Pole AFCI Circuit Breaker

Návod k použití

Zavedení

This manual provides essential information for the safe installation, operation, and maintenance of the Eaton CHFCAF120 Single Pole Arc Fault Circuit Interrupter (AFCI) Circuit Breaker. Please read all instructions carefully before beginning any work. Proper understanding and adherence to these guidelines are crucial for safe and effective use of this electrical device.

Bezpečnostní informace

VAROVÁNÍ: Risk of electric shock or electrocution. Installation and servicing of this circuit breaker must be performed by a qualified electrician. Always turn off power at the main service panel before working on electrical circuits. Failure to do so can result in serious injury or death.

POZOR: This device protects against arc faults. It is not a substitute for Ground Fault Circuit Interrupters (GFCIs) where required by electrical codes. Ensure all local and national electrical codes are followed during installation.

Vlastnosti produktu

The Eaton CHFCAF120 AFCI Circuit Breaker is designed to provide enhanced protection against electrical fires caused by arc faults. Key features include:

Specifikace

ZnačkaEaton
ModelCHFCAF120
Aktuální hodnocení20 Amps
svtage120 voltů
Typ jističeAFCI (přerušovač obvodu obloukového zkratu)
Počet pólů1
Typ montážePlug-In Mount
Rozměry produktu1.3 x 3.5 x 6 palce
Hmotnost položky0.8 unce

Instalace

DŮLEŽITÉ: Ensure all power to the electrical panel is OFF before proceeding with installation. Use appropriate personal protective equipment, including safety glasses and insulated gloves. If you are not a qualified electrician, do not attempt installation.

Kroky instalace:

  1. Odpojení napájení: Locate the main service panel and turn off the main circuit breaker to de-energize the entire panel. Verify power is off using a non-contact voltage tester on all circuits you intend to work on.
  2. Přístup k panelu: Carefully remove the cover of the electrical panel, following manufacturer guidelines.
  3. Umístění jističe: Identify an available slot in the Eaton Type CH load center. The CHFCAF120 is a single-pole breaker and requires one slot.
  4. Kabelové připojení: Connect the circuit's hot wire (typically black or red) to the terminal on the AFCI breaker labeled 'LOAD'. Tighten the screw securely to the torque specified by the panel manufacturer. Connect the neutral wire from the circuit to the neutral terminal on the AFCI breaker. Then, connect the white pigtail neutral wire from the AFCI breaker to the neutral bus bar in the panel. Refer to the wiring diagram for your specific panel for precise connections. Ensure all connections are tight and secure. For a 20 Amp breaker, use 12 gauge wire.
  5. Montáž: Align the breaker with the bus bar and firmly push it into place until it is securely seated. Ensure the pigtail neutral is properly connected and not pinched.
  6. Kryt panelu: Carefully replace the electrical panel cover, ensuring no wires are pinched.
  7. Obnovení napájení: Turn the main circuit breaker back ON.
Eaton CHFCAF120 Single Pole AFCI Circuit Breaker
Image showing the Eaton CHFCAF120 Single Pole AFCI Circuit Breaker. This breaker features a single pole design, a test button, and terminals for connecting circuit wires and a neutral pigtail. This image illustrates the general appearance of the product for identification purposes.

Operace

The Eaton CHFCAF120 AFCI Circuit Breaker operates automatically to detect and interrupt arc faults. When an arc fault is detected, the breaker will trip, cutting off power to the affected circuit to prevent potential electrical fires.

Resetování jističe:

  1. Identifikace vypnutého jističe: A tripped AFCI breaker will typically be in an intermediate position between ON and OFF, or fully in the OFF position.
  2. Vypnout: Firmly push the breaker handle to the full OFF position. This ensures the internal mechanism is reset.
  3. Zapnout: Firmly push the breaker handle to the full ON position.
  4. If the breaker immediately trips again, there may still be an arc fault or an overload condition on the circuit. Investigate and resolve the cause before attempting to reset again. Do not repeatedly reset a tripping breaker without addressing the underlying issue.

Testování

Regular testing of the AFCI breaker is recommended to ensure proper operation and continued protection. Test the breaker monthly.

Postup testu:

  1. Locate Test Button: The AFCI breaker has a 'TEST' button on its face, usually colored white or yellow.
  2. Stiskněte testovací tlačítko: With power ON to the circuit, press and hold the 'TEST' button. The breaker should immediately trip to the OFF position, cutting power to the circuit.
  3. Reset Breaker: Reset the breaker by first pushing the handle to the full OFF position, then to the full ON position.
  4. If the breaker does not trip when the test button is pressed, it may be faulty and should be replaced by a qualified electrician immediately.

Údržba

The Eaton CHFCAF120 AFCI Circuit Breaker requires minimal maintenance. Periodically inspect the breaker for any visible damage, discoloration, or loose connections. Ensure the area around the electrical panel is clear and free from obstructions to allow for proper ventilation and access. Do not attempt to open or repair the breaker yourself.

Odstraňování problémů

Běžné problémy a řešení:

Informace o záruce

For specific warranty details, including terms, conditions, and duration, please refer to the documentation provided with your original purchase or visit the official Eaton webDoporučuje se uschovat si doklad o koupi pro případné reklamace.

Zákaznická podpora

For technical assistance, product inquiries, or further support, please contact Eaton customer support. Contact information, including phone numbers and online resources, can typically be found on the Eaton website or product packaging. When contacting support, please have your product model number (CHFCAF120) and any relevant purchase details available.

Související dokumenty - CHFCAF120

Předview Průvodce instalací a testováním odbočného obvodu Eaton Outlet AFCI
Komplexní průvodce instalací a testováním zásuvek Eaton Outlet Branch Circuit AFCI, včetně bezpečnostních opatření, pokynů k zapojení, testovacích postupů, řešení problémů a informací o záruce.
Předview 伊顿新一代空气断路器 IZM9 系列:卓越的解决方案
了解伊顿新一代 IZM9系列空气断路器,为全球电力系统提供创新、可靠且高效的动力管理解决方案。该系列产品凭借先进的PXR 电子脱扣平台、增强的安全特性(如 ARMS 闪弧减少维护系统)以及强大的通讯能力,广泛应用于建筑、信息技术 工业机械和能源公用事业等多个领域,满足客户日益增长和多样化的需汱
Předview Návod k instalaci a obsluze vakuového jističe Eaton E-VAC HV
Tato příručka obsahuje základní informace o instalaci, provozu, údržbě a technických detailech pro uzavřený vnitřní vysokoobjemový systém Eaton E-VAC.tagVakuový jistič (model IL550-0501001E) zajišťující bezpečné a efektivní použití v průmyslových a energetických rozvodných aplikacích.
Předview Uživatelská příručka pro jistič Eaton Magnum LV-Air (1812.900A)
Komplexní uživatelská příručka pro jistič Eaton Magnum LV-Air (model 1812.900A) s podrobným popisem instalace, provozu, údržby, řešení problémů a náhradních dílů. Zahrnuje pevné i výsuvné konfigurace s elektronickými vypínacími systémy.
Předview EATON 11/25 IL019140ZU Návod k obsluze: Návod k instalaci proudových chráničů (RCCB) a proudových chráničů (RCBO)
Podrobné pokyny k instalaci a technické specifikace pro proudové chrániče (RCCB) a proudové chrániče s nadproudovou ochranou (RCBO) řady EATON PL6, PL7, HN, PF6, PF7 a HNC, včetně schémat zapojení a elektrických údajů.
Předview Pokyny k instalaci blokování rámových jističů LG a PD3
Návod k instalaci, montáži a seřízení blokovacího mechanismu s krokovým nosníkem pro jističe Eaton LG a PD3. Obsahuje seznam dílů, schémata a bezpečnostní upozornění.