1. Úvod
This manual provides essential information for the safe and effective use of Legrand LEG92923 10A Cartridge Fuses. These fuses are designed for the protection of electrical circuits against short circuits. Please read this manual thoroughly before installation and use.
2. Bezpečnostní informace
WARNING: Risk of electric shock. Always disconnect power before installing or replacing fuses.
- Ensure the fuse rating matches the circuit requirements. Using an incorrect fuse rating can lead to fire or damage to equipment.
- Elektrické práce by měl provádět pouze kvalifikovaný personál.
- Do not attempt to repair a blown fuse. Replace it with a new one of the same type and rating.
- Keep fuses out of reach of children.
3. Konec produktuview
The Legrand LEG92923 is a set of three domestic cylindrical cartridge fuses, each rated at 10 Amperes. They feature an indicator for easy identification of a blown fuse. These fuses are designed to interrupt the flow of excessive current, thereby protecting electrical appliances and wiring from damage due to overcurrents or short circuits.

Image 3.1: Legrand LEG92923 10A Cartridge Fuses in their original packaging, illustrating the dimensions (10.3 mm diameter, 25.8 mm length) and the 10A rating. The packaging clearly shows three fuses.

Obrázek 3.2: Detailní záběr view of the Legrand LEG92923 10A Cartridge Fuses, showing the individual fuses with their markings and cylindrical design. This image provides a clear view of the product outside its packaging.
Klíčové vlastnosti:
- Kapacita: 10 Amps
- Rozměry: 10.3 x 25.8 mm
- Indikátor: Ano
- Množství: Sada 3
4. Nastavení a instalace
These cartridge fuses are designed for through-hole mounting in appropriate fuse holders or fuse boxes. Follow these general steps for installation:
- Odpojit napájení: Before beginning any work, ensure that the main power supply to the circuit is completely disconnected at the circuit breaker or main switch. Verify with a voltage tester.
- Identifikace držáku pojistky: Locate the fuse holder where the new fuse needs to be installed or the old fuse needs to be replaced.
- Vložte pojistku: Carefully insert the Legrand LEG92923 cartridge fuse into the designated fuse holder. Ensure it is seated firmly and correctly.
- Obnovit napájení: Jakmile je pojistka bezpečně na místě, obnovte napájení obvodu.
Consult your appliance or electrical panel manual for specific fuse holder types and installation procedures.
5. Princip fungování
Legrand LEG92923 cartridge fuses operate as sacrificial devices designed to protect electrical circuits. When an overcurrent condition (such as a short circuit) occurs, the metallic element inside the fuse melts due to the excessive heat generated. This melting action breaks the circuit, stopping the flow of electricity and preventing damage to the connected equipment or wiring. The integrated indicator provides a visual cue when the fuse has blown.
6. Údržba
Fuses are maintenance-free components. They are designed for single-use protection. If a fuse blows, it must be replaced. Do not attempt to repair or bypass a blown fuse.
Výměna pojistky:
- Odpojit napájení: Always turn off the power to the circuit before attempting to replace a fuse.
- Identifikace spálené pojistky: The indicator on the Legrand LEG92923 fuse will show if it has blown.
- Vyjměte starou pojistku: Carefully extract the blown fuse from its holder.
- Instalace nové pojistky: Insert a new Legrand LEG92923 fuse (10A, 10.3 x 25.8 mm) into the holder, ensuring it is correctly seated.
- Obnovit napájení: Turn the power back on. If the new fuse blows immediately, there may be an underlying electrical fault that requires professional attention.
7. Řešení problémů
If a circuit stops working, the first step is often to check the fuse. If a Legrand LEG92923 fuse has blown (indicated by its internal indicator), it means it has successfully protected the circuit from an overcurrent event.
- Fuse Blows Immediately After Replacement: This indicates a persistent short circuit or overload in the electrical system. Do not continue to replace fuses without addressing the root cause. Disconnect the appliance or circuit and consult a qualified electrician.
- No Power, Fuse Appears Intact: Check other components in the circuit, such as the circuit breaker or the appliance itself. The issue might not be fuse-related.
Always prioritize safety. If you are unsure about any electrical issue, contact a professional electrician.
8. Specifikace
| Atribut | Hodnota |
|---|---|
| Značka | Legrand |
| Číslo modelu | 092923 |
| Číslo dílu | LEG92923 |
| ASIN | B009E6K07O |
| AC Adapter Current (Capacity) | 10 Amps |
| Rozměry položky (D x Š x V) | 0.39 x 1.57 x 4.33 inches (approx. 10.3 x 25.8 mm) |
| Materiál | Plastic (housing), Metallic (fuse element) |
| Typ montáže | Montáž do průchozího otvoru |
| Hmotnost položky | 0.64 unce |
| Množství | 3 kusy na sadu |
| Barva | Šedá |
| Požadované/součástí balení jsou baterie | Žádný |
9. Záruka a podpora
For warranty information and technical support regarding Legrand products, please refer to the official Legrand webwebu nebo se obraťte přímo na jejich zákaznický servis. Uschovejte si účtenku jako doklad o koupi.
Legrand Customer Service: Prosím navštivte www.legrand.us pro kontaktní údaje a další pomoc.