Fluke TL175

Uživatelská příručka k měřicím kabelům Fluke TL175 TwistGuard

Model: TL175

1. Úvod

The Fluke TL175 TwistGuard Test Leads are designed for electrical measurement applications, offering enhanced safety and versatility. These test leads feature an adjustable tip shroud mechanism and a WearGuard lead wire wear indication system, ensuring reliable performance and user safety across various measurement environments. They are compatible with all instruments that accept standard 4mm shrouded banana plugs.

2. Bezpečnostní informace

WARNING: To prevent possible electrical shock, fire, or personal injury:

  • Always use the test leads with the appropriate safety category rating for the measurement environment.
  • Inspect test leads for damage before each use. Do not use if insulation is damaged or if the inner contrasting color of the WearGuard system is exposed.
  • Ensure the test lead tips are fully inserted into the measurement device.
  • Neaplikujte více než jmenovitý objemtage, as marked on the test leads.
  • Keep fingers behind the finger guards on the probes during measurements.
  • Buďte opatrní při práci s objtagnad 30 V AC RMS, 42 V peak nebo 60 V DC. Tyto objemytages představují nebezpečí úrazu elektrickým proudem.

3. Vlastnosti produktu

  • TwistGuard Extendable Tip Shroud: Patented design allows users to twist the probe handle to extend or retract the tip shroud, reducing tip exposure for higher safety categories (CAT III, CAT IV) and providing full tip exposure for lower categories (CAT II).
  • WearGuard Lead Wire Indication: Each test lead features two layers of silicone insulation. If the outer layer is nicked or scuffed, the inner contrasting color becomes visible, indicating the need for replacement.
  • Double Insulated Silicone Leads: Designed to withstand high temperatures and maintain flexibility in cold conditions.
  • Extra-Heavy Duty Strain Relief: Reinforced strain relief on both probe-end and plug-end for enhanced durability, tested beyond 30,000 bends.
  • Universal Input Plugs: Compatible with all instruments that accept standard 4mm shrouded banana plugs.
  • Removable 4mm Lantern Tips: Includes removable tips that thread onto the lead tip for versatile connections.
Fluke TL175 TwistGuard Test Leads

Obrázek 1: Přesview of Fluke TL175 TwistGuard Test Leads, showing the red and black leads with their respective probe tips and banana plugs.

4. Nastavení a instalace

  1. Inspect Leads: Before connecting, visually inspect both test leads for any signs of damage, cuts, or exposed inner insulation. If damage is found, replace the leads immediately.
  2. Připojení k přístroji: Insert the shrouded banana plugs (black for common, red for voltage/current) firmly into the corresponding input jacks of your multimeter or test instrument. Ensure a secure connection.
    Fluke TL175 Test Leads connected to a multimeter

    Figure 2: Fluke TL175 Test Leads properly connected to a digital multimeter.

  3. Adjust TwistGuard Shroud: The TwistGuard feature allows you to adjust the exposed tip length.
    • For CAT II measurements (e.g., wall outlets), twist the probe handle to fully expose the 19mm tip.
    • For CAT III or CAT IV measurements (e.g., circuit breaker panels, main service), twist the probe handle to retract the shroud, exposing only the 4mm tip for increased safety.
      Hand demonstrating the TwistGuard feature on a Fluke TL175 test lead

      Figure 3: A hand twisting the probe handle to adjust the TwistGuard tip shroud.

  4. Attach Lantern Tips (Optional): If your application requires a different connection type, the included 4mm lantern tips can be threaded onto the probe tips.

5. Návod k obsluze

Once properly connected and adjusted, the Fluke TL175 Test Leads function as standard test probes for your electrical measurements. Always refer to your multimeter's instruction manual for specific measurement procedures.

  • svtage Měření: Vyberte příslušný objemtage range on your multimeter. Ensure the TwistGuard shroud is set for the correct safety category. Place the black probe on the common or ground point and the red probe on the point to be measured.
  • Aktuální měření: For current measurements, ensure the red lead is connected to the correct current input jack on your multimeter (e.g., 10A or mA). The circuit must be broken to insert the meter in series.
  • Resistance/Continuity: Select the resistance or continuity function. The leads can be used to test circuit continuity or component resistance.
Fluke TL175 Test Lead being used to measure in a circuit breaker panel

Figure 4: Using a Fluke TL175 Test Lead in a circuit breaker panel, demonstrating a CAT IV application with the shroud retracted.

Fluke TL175 Test Leads being used to test an electrical outlet

Figure 5: Fluke TL175 Test Leads used to test an electrical outlet, suitable for CAT II applications with tips fully exposed.

6. Údržba

  • Čištění: Clean the test leads with a damp hadříkem a jemným čisticím prostředkem. Nepoužívejte abrazivní čisticí prostředky nebo rozpouštědla.
  • Inspekce: Regularly inspect the leads for any signs of wear or damage, especially the WearGuard insulation. If the inner contrasting color is exposed, the leads are compromised and should be replaced to maintain safety.
  • Skladování: Store the test leads in a clean, dry environment, away from extreme temperatures and direct sunlight. Avoid sharp bends or kinks in the cables.

7. Řešení problémů

  • No Reading or Intermittent Reading:
    • Ensure the banana plugs are fully inserted into the multimeter.
    • Check for visible damage to the lead insulation or connectors.
    • Perform a continuity test on the leads themselves by touching the tips together. If no continuity, the leads may be internally broken and require replacement.
  • Nepřesná čtení:
    • Verify the multimeter is set to the correct function and range.
    • Ensure the test lead tips are making good contact with the circuit points.
    • Check for corrosion or dirt on the probe tips or banana plugs.

8. Specifikace

FunkceSpecifikace
Číslo modeluTL175
Hodnocení bezpečnostiCAT II 1000V, CAT III 1000V, CAT IV 600V, 10A maximum, Pollution Degree 2
Exposed Probe Tip Length19mm to 4mm (0.75" to 0.16") adjustable
Lead Wire MaterialDouble Insulated Silicone
Provozní teplota-20 až 55 °C (-4 až 131 °F)
Nadmořská výška2000 m (6,562 stop)
DodržováníEN61010-031
Rozměry produktu10 x 3 x 2 palce
Hmotnost položky120 gramů (4.23 unce)

Co je v krabici:

  • Fluke TL175 TwistGuard Test Leads (Red and Black)
  • Removable 4mm Lantern Tips

9. Záruka a podpora

The Fluke TL175 TwistGuard Test Leads come with a 1-year warranty from the date of purchase, covering defects in materials and workmanship. For warranty claims, technical assistance, or further information, please contact Fluke Corporation customer support or visit the official Fluke webmísto.

Výrobce: Společnost Fluke Corporation

Datum první dostupnosti: 1. června 2011

Související dokumenty - TL175

Předview Digitální multimetr Fluke 179: Průvodce údržbou a servisem v terénu
Objevte digitální multimetr Fluke 179 True-RMS, který je určen pro efektivní údržbu elektrických zařízení a systémů vytápění, větrání a klimatizace. Seznamte se s jeho funkcemi, specifikacemi a doporučeným příslušenstvím pro spolehlivý servis v terénu.
Předview Uživatelská příručka k digitálním multimetrům Fluke 15B+/17B+/18B+
Komplexní uživatelská příručka pro digitální multimetry Fluke 15B+, 17B+ a 18B+, která zahrnuje funkce, provoz, bezpečnost, údržbu a specifikace. Tento dokument poskytuje podrobné pokyny k používání multimetrů pro různá elektrická měření.
Předview Digitální multimetry Fluke 106/107 v dlani: Technické specifikace a funkce
Podrobné technické specifikace, nejdůležitější informace o produktech a obecné informace o digitálních multimetrech Fluke 106 a 107 v dlani. Seznamte se s jejich elektrickými specifikacemi, přesností, funkcemi a dodávaným vybavením.
Předview Fluke 107 Handheld CAT III Digital Multimeter - Technical Specifications
Detailed technical specifications, features, and general information for the Fluke 107 handheld CAT III digital multimeter. Includes electrical measurements, safety ratings, and ordering details.
Předview Adaptérová sada Fluke FEV100 pro nabíjecí stanice pro elektromobily: Technické údaje a specifikace
Prozkoumejte technické specifikace, funkce a testovací postupy pro adaptérovou sadu Fluke FEV100, která je určena pro bezpečné a efektivní testování nabíjecích stanic pro elektromobily (EVSE). Zahrnuje bezpečnostní informace, kompatibilitu a podrobnosti o objednávání.
Předview Multimetr Fluke 110 True-RMS: Technické specifikace a funkce
Podrobné specifikace a funkce kompaktního multimetru Fluke 110 True-RMS, určeného pro přesnou elektrickou instalaci a řešení problémů. Zahrnuje přesnost, bezpečnostní hodnocení a dodávané příslušenství.