ProTech 607011

Návod k obsluze plynového ventilu ProTech 607011 Spark Pilot Furnace

Model: 607011

Důležité bezpečnostní informace

VAROVÁNÍ: All controls should be installed by a licensed professional. Failure to read and follow all instructions carefully before installing or operating this control could cause personal injury and/or property damage.

This manual provides detailed instructions for the safe and proper installation, operation, and maintenance of the ProTech 607011 Spark Pilot Furnace Gas Valve. Please read this manual thoroughly before proceeding with any procedures.

ProTech 607011 Spark Pilot Furnace Gas Valve

Popis obrázku: Detailní view of the ProTech 607011 Spark Pilot Furnace Gas Valve. The valve features a robust metal body with various connections and wiring for spark pilot ignition systems. A black electrical component is visible on the top, with brown wires connected to brass terminals. Threaded input and output ports are located on the sides of the valve body, designed for gas line connections.

1. Nastavení a instalace

The ProTech 607011 Spark Pilot Furnace Gas Valve is designed for use in furnace systems requiring a spark pilot ignition. Proper installation is critical for safe and efficient operation.

1.1 Kontrolní seznam před instalací

1.2 kroky instalace

  1. Odpojte elektrické napájení pece.
  2. Turn off the main gas supply valve to the furnace.
  3. Carefully remove the old gas valve, noting all connections (gas lines, wiring).
  4. Apply appropriate pipe thread sealant (e.g., Rectorseal Pipe Thread Sealant #5) to the threads of the gas lines before connecting them to the new valve.
  5. Connect the input and output gas lines to the new ProTech 607011 valve. Ensure all connections are tight and leak-free.
  6. Connect the wiring harness (e.g., White-Rodgers F115-0059 / 45-25204-01) to the appropriate terminals on the gas valve. Refer to the furnace manufacturer's wiring diagram for correct connections.
  7. Mount the gas valve securely within the furnace.
  8. Slowly turn on the main gas supply and check for leaks using a suitable leak detection solution.
  9. Obnovte elektrické napájení pece.
  10. Perform initial startup and operational checks as per the furnace manufacturer's instructions.

1.3 Recommended Accessories

2. Návod k obsluze

The ProTech 607011 gas valve operates in conjunction with the furnace's control system to regulate gas flow to the pilot and main burner.

2.1 Normální provoz

  1. Upon a call for heat, the furnace control board sends a signal to the gas valve.
  2. The gas valve opens to allow gas to flow to the pilot burner.
  3. The spark igniter creates a spark to ignite the pilot flame.
  4. Once the pilot flame is established and sensed by the flame sensor, the gas valve opens further to allow gas to flow to the main burner.
  5. The main burner ignites, and the furnace begins its heating cycle.
  6. When the thermostat's call for heat is satisfied, the gas valve closes, shutting off gas to the main and pilot burners.

2.2 Převod typu plynu

This valve is designed for both Natural Gas and LP (Liquid Propane) applications. An LP conversion kit is included. Conversion must be performed by a licensed professional according to the instructions provided with the conversion kit and the furnace manufacturer's guidelines.

3. Údržba

Regular maintenance of your furnace system, including the gas valve, is essential for safe and efficient operation. All maintenance procedures should be performed by a licensed professional.

3.1 Roční kontrola

3.2 Čištění

The gas valve itself typically does not require internal cleaning. External cleaning should be limited to wiping with a dry cloth to remove dust. Do not use harsh chemicals or solvents.

4. Řešení problémů

If your furnace is not operating correctly, consult a licensed HVAC professional. Do not attempt to repair the gas valve yourself. The following are common issues that may indicate a problem with the gas valve or related components:

For all troubleshooting and repairs, it is strongly recommended to contact a qualified service technician.

5. Specifikace

FunkceDetail
Číslo modelu607011
Nahrazuje čísla dílů60-20714-12, 5651-5538, 60-20714-11, 5651-5552, 5651-5541, 60-20714-22, 5651-5540, 60-20714-10, 60-20714-70, 60-20714-92
Řada ventilů36C
Typ palivaNatural Gas and LP (Liquid Propane)
Capacity (BTU/HR @ 1 in. W.C. Pressure Drop)280,000
Opening TypeNorma
Systém zapalováníPilot
Počet Stages1
Input Fitting Size NPT3/4 palce
Output Fitting Size NPT3/4 palce
Valve Body Length4 palců
Šířka tělesa ventilu3-3/16 palce
Výška tělesa ventilu5-1/2 palce
Sada pro přestavbu LPV ceně
Wiring Harness (Recommended)45-25204-01 (White-Rodgers F115-0059)
Hmotnost položky2.6 libry
Rozměry balení6.1 x 4.7 x 4.6 palce
Vnější povrchKov
Typ vstupního připojeníNárodní zúžené potrubí
Počet portů2
UPC662766341317

6. Informace o záruce

Specific warranty details for the ProTech 607011 Spark Pilot Furnace Gas Valve are not provided in this manual. Please refer to the product packaging or contact ProTech customer service for warranty terms and conditions.

7. Zákaznická podpora

For technical assistance, service, or replacement parts, please contact your licensed HVAC professional or the manufacturer directly. Contact information for ProTech customer service is not included in this document.

Související dokumenty - 607011

Předview Katalog produktů pro kvalitu vnitřního ovzduší Protech
Komplexní katalog řešení Protech pro kvalitu vnitřního ovzduší, včetně mediálních čističek vzduchu, elektronických čističek vzduchu, UV zařízení, zvlhčovačů, odvlhčovačů, ventilátorů s rekuperací energie a tepla (ERV/HRV) a příslušenství k mini-splitovým systémům. Obsahuje produkty značek jako Rheem, Ruud, Trion, Honeywell a McDaniel Metals s podrobnými specifikacemi, čísly dílů a funkcemi.
Předview Uživatelská příručka k luxmetru Protech Pro 400K QM1584
Uživatelská příručka k luxmetru Protech Pro 400K (model QM1584) s podrobným popisem jeho funkcí, specifikací, provozních pokynů, údržby a doporučených úrovní osvětlení pro různá prostředí.
Předview Uživatelská příručka k 3D tiskárně Protech FPE1
Komplexní uživatelská příručka k 3D tiskárně Protech FPE1, která zahrnuje produkt přes...view, instalace, manipulace s filamentem, tisk, řešení problémů a nastavení Cura.
Předview Digitální mikroskop Protech QC3185 se 7" displejem, uživatelská příručka - zvětšení 1200x
Uživatelská příručka k digitálnímu mikroskopu Protech QC3185 se 7palcovým HD displejem, 12MP kamerou a plynulým zvětšením 1–1200x. Zahrnuje specifikace, provozní režimy a vylepšení pro údržbu elektroniky.
Předview Uživatelská příručka k záznamníku teploty/vlhkosti Protech QP6013
Uživatelská příručka k záznamníku teploty/vlhkosti Protech QP6013 s podrobným popisem jeho funkcí, popisem, průvodcem stavem LED diod, instalací, specifikacemi, výměnou baterie, repasí senzoru a informacemi o záruce.
Předview Uživatelská příručka k laserovému měřicímu pásmu Protech QM1627
Uživatelská příručka pro laserový měřicí pásmo Protech QM1627. Tato příručka obsahuje základní bezpečnostní předpisy a komplexní informace.view funkcí zařízení, návod k obsluze, tipy pro řešení problémů, technické specifikace a rady k údržbě.