1. Úvod

The Altronix ACM8 Access Power Controller is designed to manage power distribution for access control systems. This unit features eight individually fused trigger outputs, providing reliable power and protection for various access control devices. It is suitable for a range of applications requiring controlled power distribution.

2. Konec produktuview

The ACM8 is a versatile power distribution board, ideal for integrating with access control panels. It provides individually fused outputs, ensuring protection for connected devices. The board is constructed from durable phenolic or fiberglass material and is UL Recognized, meeting UL294 standards for access control system units.

Altronix ACM8 Access Power Controller board with eight fused outputs

Obrázek 1: Shora dolů view of the Altronix ACM8 Access Power Controller board, showing the eight fused outputs, relays, and terminal blocks.

Altronix ACM8 Access Power Controller board at an angle

Obrázek 2: Úhlové view of the Altronix ACM8 Access Power Controller, highlighting the compact design and component layout.

3. Vlastnosti

  • Eight individually fused outputs for device protection.
  • Vstupní objemtage: 12 to 24 Volt AC or DC.
  • Výstupní objemtage: 12 to 24 Volt AC or DC.
  • UL Recognized and UL294 compliant for access control applications.
  • Constructed from durable Phenolic or Fiberglass material.
  • Compact dimensions for easy integration.

4. Specifikace

SpecifikaceDetail
Číslo modeluACM8
Rozměry produktu (D x Š x V)8 x 4.5 x 1.25 palce
Vstupní objemtage12 až 24 voltů střídavého nebo stejnosměrného napětí
Výstupní objemtage12 až 24 voltů střídavého nebo stejnosměrného napětí
Počet výstupů8 (Fused)
MateriálFenol nebo sklolaminát
NormyUZNÁNO UL, UL294
Hmotnost položky11.2 unce
VýrobceALTRONIX

5. Nastavení

  1. Montáž jednotky: Securely mount the ACM8 board in a suitable enclosure or panel using appropriate hardware. Ensure adequate ventilation if enclosed.
  2. Připojení napájení: Connect the main power source (12-24V AC or DC) to the designated input terminals. Observe correct polarity when using a DC input. Refer to the board markings for positive (+) and negative (-) terminals.
  3. Výstupní připojení: Connect your access control devices (e.g., locks, readers) to the individually fused output terminals. Each output provides power when triggered. Ensure proper wiring for each connected device according to its specifications.
  4. Spouštěcí vstup: Connect the trigger input from your access control panel or other control device to the ACM8's trigger terminals. This signal will activate the corresponding output.
  5. Základy: Ensure the unit is properly grounded according to local electrical codes and safety standards.

6. Návod k obsluze

  1. Zapnutí: Once all connections are secure and verified, apply power to the ACM8 unit.
  2. LED indikátory: Each output has an associated LED indicator. When an output is active and power is flowing correctly through its fuse, the corresponding LED will illuminate.
  3. Funkce spouštěče: When a trigger signal is received at the input, the ACM8 will activate the designated output, providing power to the connected access control device.
  4. Fuse Monitoring: The LED indicators also serve as a visual check for fuse integrity. If an LED is off when the output should be active, it indicates a potential blown fuse or a wiring issue to the connected device.

7. Údržba

  • Pravidelná kontrola: Periodically inspect all wiring connections to ensure they are secure and free from corrosion or damage.
  • Výměna pojistky: If an output fuse blows, always replace it with a fuse of the same type and rating (e.g., 250V, 2A). Using an incorrect fuse can damage the unit or connected devices.
  • Čištění: Keep the unit free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners or solvents.
  • Podmínky prostředí: Ensure the operating environment remains within specified temperature and humidity ranges to prevent malfunction.

8. Řešení problémů

  • No Power to Any Outputs:
    • Verify that the main input power supply is active and correctly connected to the ACM8.
    • Check the main fuse (if applicable to your power supply) and ensure it is intact.
  • Individual Output Failure (LED off when active):
    • Check the specific output fuse for the affected channel. Replace if blown.
    • Verify the wiring to the connected device for shorts or disconnections.
    • Ensure the trigger signal for that specific output is being received correctly.
  • Přerušovaný provoz:
    • Inspect all terminal connections for looseness.
    • Zkontrolujte svtage fluctuations from the input power supply.

9. Záruka a podpora

For detailed warranty information, technical assistance, or to inquire about service, please contact Altronix customer service directly or visit the official Altronix webmísto. Uschovejte si doklad o koupi pro případ záručních reklamací.

Související dokumenty - ACM8

Předview Instalační příručka sad Altronix Trove2/Mercury s pojistkovými výstupy
Instalační návod pro sady Altronix Trove2/Mercury s podrobným popisem různých modelů pojistkových výstupů, možností konfigurace a montážních pokynů pro systémy kontroly přístupu. Obsahuje více nežview, konfigurační diagramy, kroky instalace a rozměry skříně.
Předview Instalační příručka pro sadu Altronix T2PXK78 a T2PXK78D Trove Paxton Access & Power Integration Kit
Komplexní instalační průvodce pro sady Altronix Trove Paxton (T2PXK78, T2PXK78D). Naučte se, jak nastavit pokročilé systémy řízení přístupu a integrace napájení s napájecími zdroji, řídicími jednotkami a moduly Paxton Net2 Plus od společnosti Altronix.
Předview Instalační příručka sad Altronix/Trove3 Mercury
Komplexní instalační průvodce pro sady Altronix Trove3 Mercury s podrobným popisem modelů T3MK75F16, T3MK75F16D, T3MK77F16 a T3MK77F16D. Zahrnuje produkt přesahujícíview, configuration chart, hardware, mechanical specifications, step-by-step installation instructions, and LINQ2 network module features.
Předview Instalační příručka sad Wiegand Altronix/DMP 734/734N
Komplexní instalační průvodce pro Wiegand sady Altronix/DMP 734/734N, včetně modelů T1DMK3F4, T1DMK3F4D, T2DMK7F8 a T2DMK7F8D. Zahrnuje sady přes...views, seznamy součástí, konfigurační tabulka, podrobné instalační postupy, hardwarové požadavky, schémata montáže modulů, rozměry skříně a informace o volitelném síťovém komunikačním modulu LINQ2. Nezbytné pro integrátory a techniky, kteří nastavují napájecí řešení pro řízení přístupu Altronix.
Předview Instalační příručka sad Altronix/Lenel-S2 Trove
Instalační příručka pro sady Altronix/Lenel-S2 (bezpečnostní platforma S2) Trove, včetně modelů T3SSK75F28 (pojistkové výstupy) a T3SSK75F28D (PTC výstupy). Podrobný popis obsahu sady, konfigurace a kroků instalace.
Předview Instalační průvodce sad Altronix/Honeywell ProWatch/WinPak - T2HWK78V, T2HWK78DV, T3HWK7516V, T3HWK7516DV
Komplexní instalační průvodce pro sady pro řízení přístupu Altronix a Honeywell ProWatch/WinPak, včetně modelů T2HWK78V, T2HWK78DV, T3HWK7516V a T3HWK7516DV. Zahrnuje produkt přesahujícíview, konfigurace, instalační pokyny, hardware a rozměry skříně.