This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Philips HF-R 258 TL-D EII Electronic Ballast. This electronic ballast is designed for use with 58 Watt TL-D fluorescent lamps, operating on 220-240V, 50/60Hz electrical systems.
Před instalací si prosím pečlivě přečtěte tento návod a uschovejte si jej pro budoucí použití.
2. Bezpečnostní informace
Vždy dodržujte následující bezpečnostní opatření:
- Elektrické nebezpečí: Installation and maintenance should only be performed by a qualified electrician. Ensure power is disconnected at the circuit breaker before any installation or servicing.
- svtage Kompatibilita: Ověřte, že zásoba objtage (220-240V, 50/60Hz) matches the ballast's requirements.
- Správné uzemnění: Ensure the ballast is properly grounded to prevent electrical shock.
- Lamp Kompatibilita: Use only with compatible 58 Watt TL-D fluorescent lamps.
- Podmínky prostředí: Do not expose the ballast to excessive moisture or extreme temperatures.
3. Instalace a nastavení
The Philips HF-R 258 TL-D EII electronic ballast is designed for easy integration into lighting fixtures. Follow the steps below for proper installation.
3.1. Schéma zapojení
Refer to the following diagram for correct electrical connections. Ensure all connections are secure and comply with local electrical codes.

Obrázek 3.1: Wiring diagram for the Philips HF-R 258 TL-D EII electronic ballast. This diagram illustrates the connections for the DC input (terminals 13, 14), AC input (terminals 8, 9), ground (terminal 10), and the lamp connections (terminals 1-7) for two TL-D lamps.
3.2. MCB Compatibility
The number of ballasts that can be connected to a Miniature Circuit Breaker (MCB) depends on the MCB type and rating. Consult the table below for guidance.

Obrázek 3.2: MCB compatibility table. This table provides information on the maximum number of ballasts relative to different MCB types (B, C, L, I, G, U, II, K, III) and their respective ratings (10A, 16A).
| Typ MCB | Hodnocení | Rating Relative Number of Ballasts |
|---|---|---|
| B | 16A | 100 % |
| B | 10A | 63 % |
| C | 16A | 170 % |
| C | 10A | 104 % |
| L, I | 16A | 108 % |
| L, I | 10A | 65 % |
| G, U, II | 16A | 212 % |
| G, U, II | 10A | 127 % |
| K, III | 16A | 254 % |
| K, III | 10A | 154 % |
4. Návod k obsluze
Once properly installed, the Philips HF-R 258 TL-D EII electronic ballast operates automatically to power compatible fluorescent lamps.
- Zapnutí: Apply power to the circuit. The ballast will initiate the lamps.
- Funkce stmívání: This ballast supports 1-10V dimming. Connect a compatible 1-10V dimmer to the designated dimming terminals (DC input terminals 13 and 14 as shown in the wiring diagram) to control the light output.
- Okamžitý start: Electronic ballasts provide instant, flicker-free starting for fluorescent lamps.
5. Údržba
The Philips HF-R 258 TL-D EII electronic ballast is designed for long-term, maintenance-free operation. However, general care and proper disposal are important.
- Čištění: If cleaning is necessary, disconnect power and wipe the ballast with a dry, soft cloth. Do not use abrasive cleaners or solvents.
- Lamp Nahrazení: Při výměně lamps, ensure power is off. Replace with compatible 58 Watt TL-D fluorescent lamps.
- Recyklace: Electronic ballasts and fluorescent lamps contain materials that should be recycled responsibly. Consult local regulations for proper disposal and recycling procedures.
For more information on recycling and cleaning, please refer to the manufacturer's guidelines or local waste management services.
6. Řešení problémů
If you experience issues with your Philips HF-R 258 TL-D EII electronic ballast, consider the following common problems and solutions:
- Lamps Not Lighting:
- Check the power supply to the ballast.
- Ověřte, že lamps are correctly installed and are not faulty.
- Zkontrolujte všechna kabelová spojení, zda nejsou uvolněná nebo poškozená.
- Blikající Lamps:
- Zajistěte lamps are fully seated in their sockets.
- Zkontrolujte správný objemtage zásobování.
- Lamps may be at the end of their lifespan and require replacement.
- Funkce stmívání nefunguje:
- Verify the 1-10V dimmer is compatible and correctly wired to the ballast's dimming terminals.
- Check the dimmer's power supply and functionality.
If problems persist, contact a qualified electrician or Philips Lighting customer support.
7. Specifikace
Key technical specifications for the Philips HF-R 258 TL-D EII Electronic Ballast:
| Atribut | Hodnota |
|---|---|
| Značka | Osvětlení Philips |
| Výrobce | Philips |
| Číslo modelu | 91019630 |
| Rozměry produktu (D x Š x V) | 36 x 3 x 2.2 cm |
| Hmotnost položky | 299 g |
| Počet položek | 1 |
| Styl | Moderní |
| Barva | Bílý |
| Tvar | Trubkový (T) |
| svtage | 230 voltů |
| Specifická použití | Světelná technika |
| Speciální funkce | Dimmable (1-10V) |
| Typ zástrčky | Elektrický kabel |
| Baterie jsou součástí balení/vyžadovány | Žádný |
| Kompatibilní Lamp Typ | Fluorescent (TL-D) |
| Kompatibilní Lamp Wattage | 58 Watts (as per product title) |
| Energetický štítek | 13 |
| Průměrná životnost | 50000 hodiny |
Note: Some specifications in the source data, such as "Puissance: 90 Watts" and conflicting bulb base types (GX5.3, E27), appear to be generic or refer to other products. This ballast is specifically designed for 58 Watt TL-D lamps.
8. Záruka a podpora
Warranty information for your Philips HF-R 258 TL-D EII electronic ballast is typically provided at the point of purchase or with the product packaging. Please retain your proof of purchase for warranty claims.
For technical support, service, or further inquiries, please contact Philips Lighting customer service or visit their official website. Contact details can usually be found on the product packaging or the manufacturer's webmísto.