1. Úvod
The Intermatic T104R3 is a robust mechanical time switch engineered for reliable operation in various settings, including commercial, industrial, and residential environments. This device allows for precise scheduling of electrical loads, offering up to 12 ON/OFF operations per day. Its durable construction and high motor load ratings ensure long-lasting performance. This manual provides essential information for safe installation, operation, and maintenance of your time switch.
2. Bezpečnostní informace
VAROVÁNÍ: RIZIKO ÚRAZU ELEKTRICKÝM PROUDEM
- Always turn power off at the main panel before servicing this switch or any equipment it controls.
- Use copper conductors only for wiring connections.
- Ensure the safety guard is reinstalled after completing all wiring.
- This portion of the safety guard may be removed if necessary to fit specific panel applications.
3. Konec produktuview

Obrázek 1: Vnitřní view of the Intermatic T104R3 Time Switch, highlighting the timing dial and manual override switch.
The Intermatic T104R3 features a prominent yellow timing dial with markings for AM/PM hours. Two adjustable trippers (ON and OFF) are used to program the desired operation schedule. Below the dial, a manual override lever allows for temporary control of the connected load, bypassing the programmed schedule. A safety guard covers the wiring terminals, emphasizing the importance of electrical safety.
4. Nastavení
4.1. Instalace
- Odpojení napájení: Before beginning any installation, ensure the main power supply to the circuit is completely turned off at the breaker panel. Verify with a voltage tester.
- Montáž: Securely mount the time switch enclosure to a suitable surface using appropriate hardware.
- Zapojení: Connect the electrical wiring to the designated terminals. Refer to the wiring diagram provided inside the enclosure or in the full product manual for specific connections. Ensure only copper conductors are used.
- Bezpečnostní stráž: After all wiring is complete and secure, reinstall the safety guard over the terminals.
- Obnovení napájení: Once installation is complete and verified, restore power at the main panel.
4.2. Počáteční nastavení času
- Rotate Dial: Grasp the outer edge of the yellow timing dial.
- Nastavit aktuální čas: Rotate the dial clockwise until the current time of day aligns with the stationary time pointer (usually located at the top of the dial). Ensure to differentiate between AM and PM hours.
5. Návod k obsluze
5.1. Setting ON/OFF Operations
The T104R3 uses ON and OFF trippers to program the schedule. Each tripper represents a specific time for the connected load to turn ON or OFF.
- Attach Trippers: Slide the ON tripper (typically silver) onto the outer edge of the yellow dial at the desired ON time. Slide the OFF tripper (typically gold) onto the dial at the desired OFF time.
- Secure Trippers: Ensure the trippers are firmly seated on the dial.
- Více operací: The time switch supports up to 12 ON/OFF operations per day. Additional trippers can be purchased separately if more than one ON/OFF cycle is required.
- Minimální čas: The minimum ON or OFF time for any operation is 1 hour.
5.2. Ruční ovládání
The manual override lever, located below the timing dial, allows you to temporarily control the connected load independently of the programmed schedule.
- Poloha OFF: Moves the lever to the
Související dokumenty - T104R3

Návod k instalaci celoplastového krytu časového spínače Intermatic odolného proti dešti
Podrobný návod k instalaci celoplastového krytu časového spínače Intermatic odolného proti dešti, montáž krycí skříně, připojení elektroinstalačních kabelů a požadavky na uzemnění dle Národního elektrotechnického předpisu.
Časový spínač Intermatic ET2745: Instalační a nastavovací návod pro 4obvodový elektronický časovač s 365/7denním spínačem
Podrobné pokyny k instalaci a nastavení 4obvodového elektronického 365/7denního časového spínače Intermatic řady ET2745, které zahrnují konfiguraci, programování a řešení problémů pro automatizované řízení zátěže.
Manuál k týdennímu spínači Intermatic T7402B
Podrobné pokyny a specifikace pro sedmidenní časový spínač Intermatic T7402B, včetně zapojení, programování a návodu k obsluze.
Návod k instalaci a nastavení elektronických týdenních časových spínačů Intermatic řady ET2705
Komplexní průvodce instalací, nastavením a programováním elektronických 1obvodových 7denních časových spínačů Intermatic ET2705, ET2705CR a ET2705CP. Zahrnuje zapojení, počáteční nastavení, plánování, konfiguraci letního času, přenos dat přes USB a řešení problémů.
Intermatic GM40AVE Series Electronic Commercial Time Switch Installation and Operation Manual
Comprehensive installation, operation, and troubleshooting guide for the Intermatic GM40AVE Series General Purpose Electronic Commercial Time Switches. Includes electrical ratings, wiring diagrams, application details, and warranty information. Source URL: http://waterheatertimer.org/Intermatic-timers-and-manuals.html#GM40AVE
Návod k obsluze časového spínače Intermatic 20 s pamětí
Komplexní průvodce pro paměťové časové spínače Intermatic 20, který zahrnuje bezpečnostní opatření, programování, nastavení času, přednastavené a uživatelem definované programy a informace o záruce.