Konec produktuview
The Fluke 115 Field Service True-RMS Technicians Multimeter is a compact and versatile instrument designed for a wide variety of electrical and electronic testing applications. It provides accurate True-RMS voltage and current readings, along with capabilities for testing resistance, continuity, frequency, and capacitance. Its robust design and clear display make it suitable for field technicians and professionals requiring reliable measurements.

Obrázek 1: Přední strana view of the Fluke 115 Digital Multimeter, showing the display, rotary dial, and input jacks.
Co je v krabici
- Fluke 115 Multimeter
- Pouzdro
- 9V Battery (installed)
- 4mm Silicone Test Lead Set
- Uživatelská příručka

Figure 2: Contents of the Fluke 115 package, including the multimeter, test leads, and user manual.
Nastavení
1. Instalace baterie (pokud není předinstalována)
The Fluke 115 typically comes with the 9V battery pre-installed. If replacement is needed, locate the battery access door on the back of the unit. Use a screwdriver to open the compartment, insert a new 9V battery, ensuring correct polarity, and secure the door.
2. Připojení testovacích vodičů
- Vložte černý testovací vodič do COM (společný) vstupní konektor.
- Zasuňte červený měřicí vodič do příslušného vstupního konektoru v závislosti na typu měření:
- Za svtage (V), resistance (Ω), capacitance, and frequency (Hz) measurements, use the VΩHz vstupní jack.
- For current (A) measurements up to 10A, use the 10 A FUSED vstupní jack.

Figure 3: The Fluke 115 Multimeter being held, demonstrating its compact size and ease of handling for field use.
Návod k obsluze
The Fluke 115 features a large rotary dial for selecting measurement functions and buttons for additional features like HOLD, MIN/MAX, and RANGE.
Funkce měření
- AC/DC Voltage (V∼ / V—): Select the V∼ (AC) or V— (DC) position on the rotary dial. The meter measures True-RMS voltage až 600V.
- Odpor (Ω): Select the Ω position. The meter will display resistance in Ohms.
- Kontinuita (♫): Select the continuity position. A simple beep indicates when a wire or fuse is functioning properly.
- Kapacita (⊥): Select the capacitance position. Measures capacitance values.
- Frekvence (Hz): Select the Hz position. Measures the frequency of AC signals.
- AC/DC Current (A∼ / A—): Select the A∼ (AC) or A— (DC) position. Measures current up to 10A (20A momentary for 30 seconds).
- Test diod (→|—): Select the diode test position to check diode functionality.
Speciální funkce
- Min/Max/Average: Stiskněte tlačítko MINMAX button to record signal fluctuations over time. This feature captures the minimum, maximum, and average readings.
- Držet: Stiskněte tlačítko DRŽET tlačítko pro zmrazení aktuální hodnoty na displeji.
- Rozsah: The meter features auto-ranging. Press the RANGE button to manually select a measurement range if desired.
- Podsvícení: Press the backlight button (sun icon) to illuminate the display for work in poorly lit areas.

Figure 4: The Fluke 115 Multimeter being used to take measurements on an electrical panel, highlighting its practical application.
Údržba
Výměna baterie a pojistky
To replace the battery or fuses, refer to the detailed instructions in the full user manual. The meter's yellow protective holster can be removed to access the battery and fuse compartment on the back. Ensure the meter is turned off and test leads are disconnected before attempting any maintenance.

Figure 5: The Fluke 115 Multimeter positioned on a workbench, ready for use or maintenance.
Odstraňování problémů
Běžné problémy a řešení
- No Display or Faint Display: Check battery level and replace if necessary. Ensure the battery contacts are clean. If the display remains faint, refer to the full user manual for advanced troubleshooting steps, which may involve cleaning internal display connections.
- Nepřesná čtení: Verify that the test leads are properly connected to the correct input jacks for the selected measurement function. Ensure the rotary dial is set to the appropriate function. Check for damaged test leads or probes.
- Meter Does Not Turn On: Confirm the battery is correctly installed and has sufficient charge.
Specifikace
| Funkce | Detail |
|---|---|
| Značka | Fluke |
| Číslo modelu | 115 |
| Rozměry produktu | 10.83 x 16 x 3.94 palce; 1.32 libry |
| Hmotnost položky | 600 gramů |
| Zdroj napájení | Napájení z baterií (vyžadují 2 baterie AA, jsou součástí balení) |
| Styl | TRUE RMS MULTIMETR |
| Barva | Žluť |
| Hodnocení bezpečnosti | CATIII 600V |
| svtage Měření | AC/DC Voltage až 600 V |
| Měření proudu | Current up to 10 A (20 A momentary for 30 seconds) |
| Ostatní měření | Resistance, Continuity, Frequency, Capacitance |
| Zobrazit | 6000 count resolution with large white LED backlight |
Informace o záruce
Specific warranty details for the Fluke 115 Digital Multimeter are typically provided by the manufacturer, Fluke, at the time of purchase or within the official product documentation. Please refer to the warranty card included with your product or visit the official Fluke webstránky, kde najdete nejaktuálnější a nejúplnější záruční podmínky.
Note: The provided product information includes a legal disclaimer regarding returns: "Returns accepted on all unopened merchandise. 10% restocking fee applies." This pertains to return policy and not the product's operational warranty.
Podpora
For technical assistance, product inquiries, or service, please contact Fluke customer support directly. You can find contact information and additional resources on the official Fluke webmísto.
Navštivte Obchod Fluke na Amazonu pro více produktů a informací.
Oficiální videa produktů
No official product videos from the seller were found that meet the criteria for inclusion in this manual. Videos available are from "Influencer" creators and are not embedded here.