Zavedení
This manual provides instructions for the installation, operation, and maintenance of the Intermatic T174 DPST 24 Hour Time Switch. This electromechanical timer is designed for controlling electrical loads over a 24-hour period.
Image: Intermatic T174 DPST 24 Hour Time Switch. This image shows the front view of the timer with its gray metal enclosure and the dial for setting time.
Bezpečnostní informace
WARNING: Risk of electric shock. Installation and servicing must be performed by qualified personnel only. Disconnect power at the circuit breaker or fuse box before installing or servicing the timer.
- Vždy dodržujte místní elektrotechnické předpisy a předpisy.
- Ensure the power supply matches the timer's voltage rating (208-277V AC).
- Do not exceed the maximum current and horsepower ratings of the timer.
- This device is intended for indoor use in a Type 1 enclosure.
Obsah balení
The Intermatic T174 Time Switch package typically includes:
- One (1) Intermatic T174 Time Switch Unit
- Návod k použití
- Two (2) Trippers for setting ON/OFF times
Nastavení a instalace
The Intermatic T174 is designed for fixed installation. Proper wiring is crucial for safe and correct operation.
Montáž
- Choose a suitable indoor location for mounting the timer, ensuring it is protected from moisture and extreme temperatures.
- Securely mount the timer's enclosure to a wall or suitable surface using appropriate fasteners.
Wiring (DPST Configuration)
The T174 features a Double Pole, Single Throw (DPST) contact form, meaning it controls two independent circuits or a single 2-pole circuit simultaneously.
- DISCONNECT ALL POWER to the circuit at the main service panel before proceeding.
- Otevřete kryt časovače.
- Connect the incoming power lines (L1 and L2 for 208-277V AC) to the designated "LINE" terminals on the timer.
- Connect the load wires (to the device being controlled) to the designated "LOAD" terminals. Ensure correct polarity if applicable.
- Ujistěte se, že všechny kabelové spoje jsou těsné a bezpečné.
- Close the timer's enclosure securely.
- Obnovte napájení obvodu.
Pokud si nejste jisti postupem zapojení, poraďte se s kvalifikovaným elektrikářem.
Návod k obsluze
The T174 uses a mechanical dial and trippers to set the ON/OFF schedule.
Nastavení aktuálního času
- Rotate the timer dial clockwise until the current time aligns with the "TIME SET" arrow or indicator on the timer mechanism.
- Ensure AM/PM is correctly observed if the dial has such markings.
Nastavení časů zapnutí/vypnutí
The timer comes with two trippers: one "ON" tripper and one "OFF" tripper. Additional trippers can be purchased separately (Extra Trippers 11Z965).
- Locate the "ON" tripper (typically silver or light-colored) and the "OFF" tripper (typically black or dark-colored).
- Snap the "ON" tripper onto the dial at the desired time you want the connected device to turn ON.
- Snap the "OFF" tripper onto the dial at the desired time you want the connected device to turn OFF.
- You can set up to 12 ON/OFF cycles per 24-hour period using additional trippers. The minimum time setting is 1 hour.
Ruční ovládání
The T174 typically includes a manual override switch or lever. This allows you to temporarily turn the connected device ON or OFF without affecting the programmed schedule. Refer to the specific markings on your timer for the manual override function.
Day Skipper Function
The timer features a Day Skipper function, allowing you to prevent operation on specific days of the week. Consult the detailed instruction guide included with your unit for specific setup of this feature.
Údržba
The Intermatic T174 Time Switch is designed for reliable, long-term operation with minimal maintenance.
- Periodically inspect the timer for any signs of damage or loose connections.
- Keep the enclosure clean and free from dust and debris.
- Nepokoušejte se mazat vnitřní součásti.
Odstraňování problémů
| Problém | Možná příčina | Řešení |
|---|---|---|
| Časovač nefunguje. | Časovač není napájen. | Check circuit breaker or fuse. Ensure wiring connections are secure. |
| Connected device does not turn ON/OFF at programmed times. | Incorrect tripper placement or current time setting. | Verify tripper positions and ensure the current time is accurately set on the dial. Check manual override switch position. |
| Timer motor is noisy. | Normal operation for some mechanical timers. | If noise is excessive or new, contact support. |
| Timer operates but device does not. | Faulty wiring to the load or issue with the connected device. | Verify load wiring. Test the connected device directly to ensure it is functional. |
Specifikace
| Funkce | Detail |
|---|---|
| Číslo modelu | T174 |
| Typ | Elektromechanický časovač |
| Operace | 24 hodin |
| Počet pólů | 2 |
| Kontaktní formulář | DPST-NO (Double Pole, Single Throw - Normally Open) |
| svtage | 208-277V AC |
| Ampvymazat | 40 A |
| Contact HP @ 120V | 2 hp |
| Contact HP @ 240V | 5 hp |
| Day Skipper | Ano |
| Typ krytu | Steel, Type 1 Indoor Enclosure |
| Dokončit | Gray Enamel |
| Nastavení minimálního času | 1 hodina |
| Nastavení maximálního času | 23 hodin |
| Maximum ON/OFF Cycles | 12 |
| Rozměry (V x Š x H) | 7 13/16 in x 5 in x 3 in (Approximate) |
| Hmotnost položky | 2.75 - 2.8 libry |
| Included Trippers | 2 |
| UPC | 078275174214 |
| Výrobce | Intermatic Incorporated |
Záruka a podpora
The Intermatic T174 Time Switch comes with a manufacturer's warranty. For specific warranty details, please refer to the documentation included with your product or visit the official Intermatic webmísto.
For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Intermatic customer service. You can often find support information and additional resources on the Obchod Intermatic na Amazonu nebo jejich oficiální korporátní webmísto.





