Mypin LM8-IRRD

Mypin LM8-IRRD Weighing Controller User Manual

Model: LM8-IRRD

1. Úvod

The Mypin LM8-IRRD is an advanced weighing controller designed for precise measurement and control in various industrial applications. It features a clear digital display, multiple alarm outputs, and compatibility with 1-4 load cells, making it suitable for platform scales, batching systems, and automated filling processes. This manual provides essential information for the installation, operation, and maintenance of your LM8-IRRD controller.

2. Konec produktuview

The LM8-IRRD weighing controller is a compact and robust device featuring a dual digital display for Process Value (PV) and Set Value (SV), along with alarm indicators and unit displays. Its intuitive button interface allows for easy configuration and operation.

Rozložení předního panelu

Front panel of the Mypin LM8-IRRD Weighing Controller showing PV and SV displays, alarm indicators, and control buttons.
Figure 2.1: Front Panel of LM8-IRRD Controller
  • PV (procesní hodnota): Top display, shows the current measured weight.
  • SV (Nastavená hodnota): Bottom display, shows the target weight or alarm threshold.
  • AL1, AL2, AL3: Alarm indicator lights.
  • T: Tare indicator.
  • Kg, g: Weight unit indicators (Kilograms, grams).
  • Tlačítko SET: Používá se pro vstup do režimu nastavení parametrů a potvrzení výběru.
  • <</RST Button: Used for shifting digits during setting or resetting functions.
  • Tlačítko šipka nahoru: Used to increase values or navigate menu options.
  • Tlačítko šipka dolů: Used to decrease values or navigate menu options.

3. Specifikace

The following table details the technical specifications of the Mypin LM8-IRRD Weighing Controller:

Diagram showing product dimensions and a table of specifications in Chinese.
Obrázek 3.1: Rozměry a specifikace produktu
ParametrSpecifikace
Název produktuLM Series Automatic Weighing, Filling, and Batching Controller
Model produktuŘada LM8
Celkové rozměry48 mm (V) x 96 mm (Š) x 80 mm (H)
Panel Opening SizeRozměr 45 mm x 91 mm
Čistá hmotnost≤ 0.3 kg
Rozsah aplikaceFloor scales, cement, food packaging, chemical batching, filling, and other automated control
Hlavní funkceDisplay weighing value and control it
VstupmV signal, can connect 1-4 load cells
Výstup2 RELAY relay outputs
Rychlost odezvy10krát za sekundu
Pomocná síla5V DC
Napájení110 / 220V AC
Total Machine Power Consumption< 3 W
Display Weighing Range-1999 až 9999

4. Nastavení

4.1 Instalace

The LM8-IRRD controller is designed for panel mounting. Ensure the mounting panel has an opening of 45mm x 91mm. Insert the controller into the opening and secure it using the provided mounting clips on the sides.

Strana view of the Mypin LM8-IRRD Weighing Controller showing mounting clips.
Figure 4.1: Controller with Mounting Clips

4.2 Zapojení

Proper wiring is crucial for the safe and correct operation of the weighing controller. Refer to the wiring diagram typically found on the top label of the device or in a dedicated wiring manual. Ensure all connections are secure and comply with local electrical codes.

  • Napájení: Connect the controller to a 110V or 220V AC power source as indicated on the device.
  • Load Cell Input: The controller accepts mV signals and can connect 1 to 4 load cells. Ensure correct polarity and wiring configuration for your specific load cells.
  • Reléové výstupy: The controller provides 2 RELAY relay outputs for control purposes. Connect these to your external control devices (e.g., valves, motors) according to your application's requirements.
  • 4-20mA Výstup: The LM8-IRRD model includes a 4-20mA analog output. Connect this output to compatible devices for analog signal transmission, such as PLCs or data acquisition systems.

Warning: Incorrect wiring can damage the device and pose electrical hazards. If you are unsure, consult a qualified electrician or technician.

5. Návod k obsluze

5.1 Základní obsluha

  1. Zapnutí: After ensuring all wiring is correct, apply power to the controller. The display will light up, showing the current Process Value (PV) and Set Value (SV).
  2. Vážení: Place the item on the connected scale. The PV display will show the measured weight.
  3. Funkce tárování: To zero out the weight of a container, press the appropriate button (often indicated by 'T' or a similar symbol, or a combination with 'RST' if not a dedicated button) while the container is on the scale. The PV display should reset to zero.

5.2 Setting Parameters (Set Value, Alarms)

The 'SET' button is typically used to enter and navigate the parameter setting menu. The 'Up' and 'Down' arrow buttons adjust values, and the '<</RST' button can be used to shift digits or confirm settings.

  1. Vstupte do režimu nastavení: Press and hold the 'SET' button for a few seconds until the display changes, indicating entry into the parameter setting mode.
  2. Parametry navigace: Use the 'SET' button to cycle through different parameters (e.g., SV1, SV2 for set points, alarm thresholds, unit selection, calibration settings).
  3. Upravit hodnoty: When a desired parameter is displayed, use the 'Up' and 'Down' arrow buttons to adjust its value. Use the '<</RST' button to move the cursor between digits for precise input.
  4. Uložit nastavení: After adjusting a parameter, press 'SET' again to move to the next parameter or to save and exit the setting mode (often by holding 'SET' or waiting for a timeout).

5.3 Kalibrace

Calibration is essential for accurate weighing. The specific calibration procedure will vary but generally involves:

  1. Entering calibration mode (usually a specific key combination or menu option).
  2. Zero-point calibration (with no load on the scale).
  3. Span calibration (using a known reference weight).
  4. Exiting and saving calibration settings.

Refer to the detailed calibration instructions provided with your specific model or consult the manufacturer's technical support for precise steps.

6. Údržba

  • Čištění: Keep the controller's front panel clean using a soft, dry cloth. Avoid abrasive cleaners or solvents that could damage the display or casing.
  • Podmínky prostředí: Ensure the controller operates within its specified environmental conditions (temperature, humidity) to prevent malfunction.
  • Spojení: Pravidelně kontrolujte veškeré kabelové spoje, zda nejsou těsné a zda nevykazují známky koroze nebo poškození.
  • Rekalibrace: Recalibrate the weighing controller periodically or if you suspect inaccuracies, especially after significant environmental changes or prolonged use.

7. Řešení problémů

Tato část obsahuje základní kroky pro řešení běžných problémů. V případě složitějších problémů kontaktujte technickou podporu.

ProblémMožná příčinaŘešení
Displej je prázdnýNo power, incorrect wiring, faulty power supply.Zkontrolujte připojení napájení a ujistěte se, že je hlasitost správná.tage, test power supply.
Nepřesné údaje o hmotnostiNeeds calibration, faulty load cell, environmental interference.Perform calibration, check load cell wiring and function, minimize vibrations or drafts.
Alarmy se nespouštějíSet values incorrect, alarm output wiring issue, alarm function disabled.Verify SV settings, check relay output connections, ensure alarm function is enabled in parameters.
Tlačítka nereagujíKeypad malfunction, device frozen.Try power cycling the device. If issue persists, contact support.

8. Uživatelské tipy

  • Always ensure the load cell is properly installed and secured to the platform for stable readings.
  • Regularly check the 4-20mA output signal with a multimeter to ensure it is functioning correctly, especially if integrating with other control systems.
  • Keep a record of your calibration dates and any adjustments made to parameters for future reference.

9. Záruka a podpora

For warranty information, technical support, or service inquiries, please refer to the documentation provided at the time of purchase or contact your vendor. Keep your purchase receipt as proof of purchase.

Související dokumenty - LM8-IRRD

Předview Návod k obsluze a návod k použití pro vážící kontrolér MYPIN řady LM
Komplexní průvodce pro váhový kontrolér MYPIN řady LM, zahrnující instalaci, provoz, nastavení parametrů a komunikační protokoly Modbus. Zahrnuje podrobné specifikace, informace pro objednání a montážní rozměry.
Předview Návod k obsluze inteligentního senzorového měřicího přístroje MYPIN řady D | Specifikace a zapojení
Komplexní návod k obsluze pro inteligentní senzorový měřič MYPIN řady D. Zahrnuje specifikace, provoz, nastavení parametrů, schémata zapojení a řešení problémů pro modely DM8A, DK8A a DM8E.
Předview Návod k obsluze regulátoru teploty MYPIN řady TA
Komplexní návod k obsluze regulátorů teploty MYPIN řady TA (TA4, TA6, TA7, TA8, TA9) s podrobným popisem specifikací, instalace, nastavení parametrů, aplikací a řešení problémů pro průmyslovou regulaci teploty.
Předview Návod k obsluze čítače/měřiče délky/dávek MYPIN řady FH
Návod k obsluze pro čítače, délkové a dávkové měřiče řady MYPIN FH. Zahrnuje specifikace, funkce, objednávání, provoz, vstupní/výstupní režimy a připojení svorek pro modely FH4, FH7 a FH8.
Předview Inteligentní měřiče řady MYPIN FH: Frekvence, tachometrie, čítání, dávkové měření - Technické specifikace
Komplexní technické specifikace, funkce a provozní režimy inteligentních měřičů řady MYPIN FH, včetně funkcí měření frekvence, tachometrie, počítání a dávkování. Tento dokument podrobně popisuje rozměry, parametry a schémata zapojení.
Předview Návod k obsluze jednofázového měřiče výkonu MYPIN řady DW - Technická příručka
Komplexní návod k obsluze jednofázového elektroměru MYPIN řady DW. Zahrnuje specifikace, provoz, schémata zapojení, nastavení parametrů a aplikace pro přesné elektrické měření.