Multimetr ANENG SZ26

Návod k použití multimetru ANENG SZ26

Model: SZ26 | Značka: ANENG

1. Úvod

The ANENG SZ26 Multimeter is a specialized instrument designed for automotive maintenance and general electrical measurements. It features a robust design, ease of operation, and provides accurate readings with a comprehensive set of functions. Equipped with a new protective cover and a large-screen LCD, it includes a prompt input jack and a PTC thermistor at the input terminal for enhanced protection of its core components.

This multimeter is capable of measuring DC voltage, current, AC voltage, resistance, crystal diode, circuit continuity (on/off), automotive distributor touchpoint closing angle, and engine speed. It serves as an ideal portable tool for professional automotive inspection, repair, engineering design, experimental testing, and production testing.

2. Bezpečnostní pravidla a opatření

This manual provides essential instructions for safe operation and maintenance of the instrument. Improper use may lead to damage or injury. This instrument is designed and manufactured in strict compliance with GB4793.1 and IEC/EN61010-1 safety standards for electronic measuring instruments, featuring double insulation and overvoltage standards CATIII 1000V and CATII 600V, pollution class 2.

  1. Before use, always inspect the insulating layer of the test leads for any damage, exposed wires, or disconnections. Do not use the instrument if the back cover is not properly secured, as this poses a risk of electric shock.
  2. When measuring, avoid touching exposed wires, connectors, and unused input terminals or circuits.
  3. Měřicí objemtages above 60V DC or 30V AC presents a potential risk of electric shock. Exercise extreme caution to prevent shock.
  4. Always select the correct range and function for your measurement. If the measurement value is unknown, start with the highest range setting.
  5. Do not measure currents or voltages that exceed the maximum values indicated on the port or rotary switch to prevent electric shock and instrument damage.
  6. Before changing the function/range switch for current measurements, ensure the test leads are unplugged to avoid damaging the mechanical protection device.
  7. Never insert the test leads into the current port to test voltage, as this will damage the meter or cause an accident.
  8. Do not rotate the function/range switch while actively measuring.
  9. Before measuring resistance, performing continuity tests, or diode tests, ensure the power supply to the circuit is off and all high-voltage kondenzátory jsou vybité.
  10. Do not use or store the instrument in environments with high temperatures, high humidity, flammable or explosive gases, or strong electromagnetic fields.
  11. Do not attempt to modify the internal circuit of the meter, as this may cause damage to the meter and compromise safety.
  12. When the LCD displays the "" symbol, it indicates that the battery voltage is low and the battery should be replaced promptly to maintain measurement accuracy.
  13. If a fuse replacement is necessary, use only fuses with the same specifications and models.
  14. Wear appropriate eye protection when testing or repairing a car to prevent foreign objects from entering the eyes.
  15. Perform automotive operations and maintenance in a well-ventilated area to avoid inhaling toxic gases.
  16. To prevent electric shock, turn off the car engine before connecting or removing the test leads.
  17. If the car engine is running, keep the instrument and accessories away from the engine or exhaust pipe to prevent damage from high temperatures.
  18. Always refer to the car manufacturer's warnings, precautions, and repair procedures when working on a vehicle.

3. Konec produktuview

3.1. Schéma panelu

The ANENG SZ26 Multimeter features a clear layout for easy operation. Below is a description of its main components:

ANENG SZ26 Multimeter front panel with LCD display and rotary switch

Figure 1: ANENG SZ26 Multimeter Front Panel

  1. LCD displej: Shows numerical measured values.
  2. Tlačítko NAPÁJENÍ: Tlačítko napájení pro zapnutí/vypnutí zařízení.
  3. Tlačítko HOLD: Press once to lock the current reading on the display, press again to unlock.
  4. Gear Dial (Rotary Switch): Volí funkci a rozsah měření.
  5. A Current Socket: Input for currents ≥ 200mA.
  6. mA Current Socket: Input for currents < 200mA.
  7. COM Public Socket: Common negative input for all measurements (black test lead).
  8. VΩHz°C Socket: Vstup pro svtage, resistance, frequency, temperature, speed, and closed angle measurements (red test lead).

3.2. Mezinárodní elektrické symboly

SymbolPopis
---Stejnosměrný proud
~Střídavý proud
AC/DC
Warning: Pay attention to safety signs
Vysoký objemtage hazard (electric shock hazard)
Základy
Double or highly insulated
Pojistka
Baterie

4. Nastavení

4.1. Instalace baterie

The ANENG SZ26 Multimeter requires a 9V (6F22 type or equivalent) battery for operation. To install or replace the battery:

  1. Najděte přihrádku na baterie na zadní straně přístroje.
  2. Otevřete kryt bateriového prostoru.
  3. Remove the old battery (if any) and insert a new 9V 6F22 battery, ensuring correct polarity.
  4. Bezpečně zavřete kryt prostoru pro baterie.

Video: Demonstrates battery installation (0:08-0:11).

5. Návod k obsluze

5.1 Měření DC/AC napětítage

  1. Power on the multimeter and select the DC voltage (V---) or AC voltage (V~) gear using the rotary switch.
  2. Insert the red test lead into the VΩHz°C socket and the black test lead into the COM socket.
  3. Use the stylus probes to contact the test points on the circuit.
  4. The display screen will show the measured voltage hodnota.
Multimeter measuring AC and DC voltage

Image: Functional measurement of AC and DC voltage.

5.2. Measuring DC Current

  1. After powering on, select the appropriate current measurement gear (A or mA).
  2. Insert the red test lead into the A or mA socket (depending on the expected current range) and the black test lead into the COM socket.
  3. Connect the test probes in series with the circuit under test.
  4. The measured current value will be displayed on the screen.

Poznámka: When measuring current in the mA range, the signal must be input from the mA-COM jack. For currents in the A range, the signal must be input from the A-COM jack. Failure to do so may result in inaccurate readings or instrument damage. Always connect in series.

Warning against direct contact for AC current measurement and correct series connection diagram

Image: Warning for incorrect AC current measurement and correct series connection.

5.3. Měření odporu

  1. Select the resistance measurement (Ω) gear after powering on.
  2. Insert the red test lead into the VΩHz°C socket and the black test lead into the COM socket.
  3. Use the stylus probes to contact the desired circuit test points.
  4. The measured resistance value will be displayed on the screen.

5.4. Diode and Continuity (On-Off) Judgment

  1. Select the diode/continuity ( ) gear after booting.
  2. Insert the red test lead into the VΩHz°C socket and the black test lead into the COM socket.
  3. For diode testing, connect the red test lead to the positive pole of the diode and the black test lead to the negative pole. The screen will display the voltage hodnota diody.
  4. For continuity testing, touch the probes to both ends of the component or wire. If the measured resistance is less than 50 ohms, the buzzer will sound, indicating continuity. No sound indicates an open circuit or damage.

5.5. Engine Closure Angle (DWELL) Measurement

The closing angle refers to the duration the touchpoint remains closed during the ignition cycle, which is crucial for optimal ignition energy accumulation. An incorrect closing angle can lead to ignition coil damage or reduced engine performance.

  1. Insert the black test lead into the COM socket and the red test lead into the VΩHz°C socket.
  2. According to the number of engine cylinders, set the function switch to the corresponding "DWELL" range.
  3. Connect the black test lead to the iron (ground) or the negative electrode of the battery.
  4. Connect the red test lead to the voltage terminal of the distributor or the negative (-) end of the ignition coil.
  5. Start the engine and read the closing angle from the multimeter display.

Pozor:

  • For best results, consult the engine manufacturer's technical specifications. Typical normal closing angles are: 3-cylinder engine: 60-80 degrees; 4-cylinder engine: 45-60 degrees; 5-cylinder engine: 36-48 degrees; 6-cylinder engine: 30-40 degrees; 8-cylinder engine: 22.5-30 degrees.
  • If the measured angle is too large, the touchpoint gap is too large. If the angle is too small, the touchpoint gap is too narrow.
Instructions for measuring engine closure angle (Dwelling)

Image: Engine closure angle (Dwelling) measurement instructions.

5.6. Engine Speed (RPM) Measurement

  1. Insert the black test lead into the COM socket and the red test lead into the VΩHz°C socket.
  2. According to the number of engine cylinders, set the function switch to the corresponding "RPM" range.
  3. Connect the black test lead to the iron (ground) or the negative electrode of the battery.
  4. Connect the red test lead to the low-voltage terminal of the distributor or the negative (-) end of the ignition coil.
  5. Start the engine. The data displayed on the meter should be multiplied by 10 to obtain the actual engine speed in RPM.
Instructions for measuring engine speed (RPM)

Image: Engine speed measurement instructions.

6. Údržba

6.1. Výměna baterie

When the low battery symbol "" appears on the LCD, replace the 9V battery:

  1. Vypněte multimetr a odpojte všechny měřicí kabely.
  2. Open the battery compartment on the back of the instrument.
  3. Remove the old 9V 6F22 battery and replace it with a new one, observing correct polarity.
  4. Zavřete a zajistěte kryt baterie.

6.2. Výměna pojistky

If the multimeter's current measurement function stops working, the fuse may need replacement:

  1. Vypněte multimetr a odpojte všechny měřicí kabely.
  2. Open the screws on the back cover of the instrument.
  3. Carefully remove the damaged fuse.
  4. Replace it with a fuse of the exact same specifications and model.
  5. Securely close the back cover with the screws.

6.3. Čištění a skladování

  • Before cleaning the multimeter's casing, always remove the battery.
  • Do not use alcohol or other chemical liquids to wipe the instrument, as this may damage the casing and silk screen.
  • Prevent water from seeping into the inside of the meter during cleaning to avoid electrical leakage.
  • After cleaning, allow the meter to dry completely before reinstalling the battery for use.
  • Store the instrument in a dry, cool environment, away from high temperatures, high humidity, and strong electromagnetic fields.

7. Řešení problémů

  • Displej „OL“: This indicates an overload or out-of-range measurement. Ensure you have selected the correct function and range. If measuring resistance, diode, or continuity, ensure the circuit is de-energized and capacitors are discharged.
  • Žádný nebo nepřesný odečet: Check if the test leads are properly connected and undamaged. Verify that the correct function and range are selected. If the low battery indicator is on, replace the battery.
  • No Buzzer Sound During Continuity Test: If the probes are touching a continuous path but no sound is heard, it indicates an open circuit or damage to the component/wire being tested.
  • Multimeter Not Powering On: Zkontrolujte baterii. Ujistěte se, že je správně nainstalována a dostatečně nabitá. V případě potřeby ji vyměňte.
  • Měření proudu nefunguje: Check the fuse. If blown, replace it with a fuse of the exact same specifications. Ensure the test leads are connected to the correct current input jacks (A or mA) and the measurement is done in series.

8. Specifikace

8.1. Obecný výkon

  • Konvertor: Low-power CMOS dual-integral A/D converter.
  • Oprava: Automatic zero correction.
  • Zobrazení polarity: Automatic polarity display.
  • Pozastavení dat: Ano.
  • Indikátory: Low battery and overrange indication.
  • Funkce: 24 selectable gears.
  • Ochrana proti přetížení: Full-scale overload protection.
  • Automatické vypnutí: The power automatically turns off after approximately 15 minutes of inactivity to conserve battery life.
  • Maximální zobrazená hodnota: 1999 (3 1/2 digits).
  • LCD displej: High contrast, clear, and beautiful characters.
  • Napájení: 9V battery (6F22 type or equivalent).
  • Rozměry: 177 mm x 77 mm x 40 mm.
  • Hmotnost: Approximately 175g (excluding batteries, sheaths, and test leads).
  • Teplota pracovního prostředí: 0°C to 40°C (relative humidity < 80%).
  • Teplota skladovacího prostředí: -10°C to 50°C (relative humidity < 85%).

8.2. Technické ukazatele

Table of ANENG SZ26 Multimeter functions, ranges, resolutions, and precisions

Image: ANENG SZ26 Multimeter Function and Range Table.

FunkceRozsahRezolucePřesnostMaximální hodnota
Stejnosměrný proud200 mA0.1 mA± (1.5% + 5 dny)200 mA
(mA/A)10A10 mA± (1.5% + 10 dny)10A
DC svtage200mV0.1mV± (1.5% + 10 dny)
(mV/V)2V1mV
20V10mV± (1.0% + 5 dny)1000V
200V100mV
1000V1V± (1.2% + 10 dny)
AC svtage2V1mV± (1.5% + 5 dny)
(V ~)20V10mV750V
200V100mV
750V1V± (1.5% + 10 dny)
AC response frequency: 40Hz~400Hz sine wave effective value (average response)
Odpor200Ω0.1Ω± (1.5% + 10 dny)
(Ω)2.000kΩ20 MΩ
20.00kΩ10Ω± (1.0% + 5 dny)
200.0kΩ100Ω
2.000 MΩ1kΩ± (1.5% + 10 dny)
20.00 MΩ10kΩ
Overload protection: 250Vdc or 250Vac RMS
Testování diod2V0.001VForward DC current: about 1mA; reverse DC voltage: about 1.5V. The display shows the approximate forward voltage kapka diody.
Overload protection: 250Vdc or 250Vac RMS
Continuity (Beep on/off)When the built-in buzzer sounds, the measured resistance is not greater than about 50Ω. Open circuit voltage: about 500mV.
Closure Angle4CYL: 0~90°± (3% + 5 dny)
6CYL: 0~60°
8CYL: 0~45°
Overload protection: 250V DC or AC RMS (within 10 seconds)
Speed (rev/min) PRM4CYL: 500~10000RPM1X10RPM± (3% + 5 dny)
6CYL: 500~10000RPM
8CYL: 500~10000RPM
Overload protection: 250V DC or AC RMS (within 10 seconds)

9. Uživatelské tipy

  • For automotive measurements, always ensure the engine is off before connecting or disconnecting test leads to prevent electric shock and ensure accurate readings.
  • When measuring current, remember to connect the multimeter in series with the circuit. Connecting it in parallel will likely damage the device.
  • Utilize the data hold function (HOLD button) to freeze readings on the display, which is especially useful in situations where it's difficult to view the screen directly during measurement.
  • The built-in bracket on the back of the multimeter allows for convenient hands-free operation, improving safety and ease of use.

10. Záruka a podpora

ANENG is committed to providing high-quality products and customer satisfaction. If you encounter any issues or have questions regarding the use, quality, or performance of your ANENG SZ26 Multimeter, please contact ANENG's professional after-sales support team.

For product-related inquiries or assistance with troubleshooting, a certain degree of electrical knowledge is beneficial. If you experience operational problems or require assistance with product usage, our experts are available to provide timely solutions and support.

Please note that damage resulting from improper use or artificial modification of the product is not covered under standard warranty terms. Always adhere to the operating instructions to ensure the longevity and safe operation of your multimeter.

ANENG after-sales support information with contact points for quality issues, refunds, and product use

Image: ANENG After-Sales Support Information.

Související dokumenty - Multimetr SZ26

Předview Uživatelská příručka k dotykovému měřiči ANENG 683: Vlastnosti, specifikace a návod k obsluze
Komplexní uživatelská příručka k digitálnímu multimetru ANENG 683. Zahrnuje bezpečnost, specifikace, měřicí funkce (sv.tage, proud, odpor atd.) a provozní pokyny pro elektrické zkoušky.
Předview Návod k obsluze digitálního multimetru ANENG AN8205C
Komplexní návod k obsluze digitálního multimetru ANENG AN8205C, který zahrnuje bezpečnostní informace, specifikace, návod k obsluze pro různá měření a údržbu.
Předview Návod k obsluze digitálního multimetru ANENG SZ305
Tato příručka obsahuje komplexní bezpečnostní informace, pokyny k obsluze, specifikace a podrobnosti o údržbě digitálního multimetru ANENG SZ305, kompaktního ručního elektronického měřicího přístroje napájeného z baterií.
Předview Uživatelská příručka digitálního multimetru ANENG AN870
Uživatelská příručka k digitálnímu multimetru ANENG AN870 s podrobným popisem jeho funkcí, specifikací, bezpečnostních informací, provozních pokynů, údržby a řešení problémů.
Předview Profesionální třída ANENG ST201amp Uživatelská příručka k měřiči | Průvodce funkcemi a obsluhou
Komplexní uživatelská příručka pro ANENG ST201 Professional Clamp Měřič. Seznamte se s jeho funkcemi, specifikacemi, bezpečnostními opatřeními a návodem k obsluze pro přesná elektrická měření.
Předview Digitální měnič střídavého proudu ANENG ST180 s 4000 číslicemiamp Specifikace a funkce multimetru
Podrobné specifikace a vlastnosti ANENG ST180, digitálního měniče střídavého proudu s 4000 číslicemiamp multimetr. Zahrnuje měření pro AC/DC napětítage, střídavý proud, odpor, kapacita, frekvence a teplota.