1. Konec produktuview
The SEAFLO Bilge Pump Control Switch is a marine-grade panel designed to provide reliable control over your bilge pump system. It offers three operational positions: Automatic (AUTO), Off (OFF), and Manual (MAN), allowing for flexible management of water levels in your vessel. This waterproof switch panel is built for durability in marine environments and includes an LED indicator for operational status and protection against intermittent high current. It is suitable for yachts, RVs, and other marine applications.

Figure 1: SEAFLO Bilge Pump Control Switch Panel (SFASP1-01)
2. Specifikace
| Funkce | Specifikace |
|---|---|
| Číslo modelu | SFASP1-01 (and variations: SFASP2-01, SFSP-01, SFSP-015-01, SFSP-02, SFSP-015-02) |
| svtage | 12V a 24V DC |
| Current (Fuse) | 15A (for SFSP-015-01, SFSP-015-02 models) |
| Přepnout pozice | 3-position (AUTO-OFF-MAN) or 2-position (OFF-ON) depending on model |
| Materiál panelu | Aluminum / Black Plastic |
| LED indikátor | Yes (when switch is ON/MANUAL) |
| Osvědčení | CE |
| Hmotnost (přibližně) | 0.1 lbs - 0.13 lbs (depending on model) |
| Rozměry balení (D x Š x V) | 11 cm x 7 cm x 4 cm |
| Hmotnost balení | 0.5 kg |
2.1 Rozměry

Figure 2: Dimensions for 3-Position Switch Panel (e.g., SFSP-02)

Figure 3: Dimensions for 3-Position Toggle Switch Panel with Fuse (e.g., SFSP-015-01)

Figure 4: Dimensions for 2-Position Switch Panel (e.g., SFSP-01)
3. Instalace
The SEAFLO Bilge Pump Control Switch is designed for simple and clean installation. Ensure all power is disconnected from the battery before beginning installation to prevent electrical shock.
3.1 Schéma zapojení

Figure 5: Typical Wiring Diagram for Bilge Pump System
3.2 kroky instalace
- Vyberte místo montáže: Select a flat, accessible surface on your marine vessel or RV for mounting the switch panel. Ensure it is protected from direct water spray if not explicitly rated for submersion.
- Cut Mounting Hole: Use the provided dimensions (refer to Figures 2, 3, or 4 for your specific model) to cut an appropriate opening for the switch panel.
- Připojení kabeláže:
- Connect the positive (+) wire from your battery to the input terminal of the overload protector (if applicable) and then to the switch's power input.
- Connect the manual (MAN) output from the switch directly to the positive (+) terminal of the bilge pump.
- Connect the automatic (AUTO) output from the switch to the positive (+) terminal of the float switch. The other terminal of the float switch should then connect to the positive (+) terminal of the bilge pump.
- Connect the negative (-) wire from the bilge pump and the float switch (if applicable) directly to the negative (-) terminal of your battery or a common ground point.
- Ensure all connections are secure and properly insulated using marine-grade connectors (e.g., heat shrink butt connectors) to prevent corrosion and short circuits.
- Montáž panelu: Secure the switch panel into the cutout using the provided screws.
- Test funkčnosti: Reconnect power and test all switch positions (AUTO, OFF, MAN) to ensure the bilge pump operates correctly.
Poznámka: Some models may include a built-in fuse or require an external fuse. Always ensure proper fusing for your bilge pump circuit to protect against overcurrent.
4. Provoz
The SEAFLO Bilge Pump Control Switch provides intuitive control over your bilge pump. The LED indicator illuminates when the pump is actively running.
4.1 3-Position Switch (AUTO-OFF-MAN)
- AUTO (Automatic) Position: In this position, the bilge pump will operate automatically, activated by a connected float switch. When the water level rises and triggers the float switch, the pump will turn on. Once the water level drops and the float switch deactivates, the pump will turn off.
- Poloha OFF: This position completely deactivates the bilge pump. The pump will not run, regardless of the float switch position or manual input.
- MAN (Manual) Position: In this position, the bilge pump will run continuously, bypassing the float switch. Use this for manual dewatering or testing. Remember to switch back to AUTO or OFF when manual operation is no longer needed to prevent battery drain or pump damage.
4.2 2-Position Switch (OFF-ON)
- Poloha OFF: The bilge pump is completely deactivated.
- Pozice ON: The bilge pump will run continuously. This type of switch is typically used in conjunction with an external float switch and a separate manual override switch, or for simple manual operation.
5. Údržba
Regular maintenance ensures the longevity and reliable operation of your bilge pump control switch.
- Zkontrolujte kabeláž: Periodically check all wiring connections for corrosion, fraying, or loose terminals. Ensure connections are tight and insulated.
- Čistý panel: Wipe down the switch panel with a damp cloth to remove salt, dirt, and grime. Avoid abrasive cleaners or solvents that could damage the panel finish or markings.
- Test funkčnosti: Regularly test the switch in all positions (AUTO, OFF, MAN) to confirm proper operation. For AUTO mode, manually lift the float switch to ensure the pump activates.
- Check for Water Ingress: Although waterproof, inspect the panel for any signs of water ingress, especially around mounting screws or cable entries. Ensure seals are intact.
6. Řešení problémů
If your bilge pump system is not functioning as expected, follow these troubleshooting steps:
- Pump Does Not Run in MAN/ON Position:
- Zkontrolujte objem baterietage.
- Zkontrolujte všechna kabelová spojení, zda nejsou uvolněná nebo korozi.
- Check the fuse or circuit breaker for the bilge pump circuit. Replace if blown.
- Verify the bilge pump itself is operational by connecting it directly to a 12V/24V power source (briefly).
- Pump Does Not Run in AUTO Position (but runs in MAN/ON):
- Check the float switch. Manually lift the float to see if the pump activates.
- Inspect wiring between the switch, float switch, and pump for any breaks or loose connections.
- Ensure the float switch is clean and free from debris that might impede its movement.
- Pump Runs Continuously in AUTO Position:
- Check the float switch. It might be stuck in the "up" (activated) position due to debris or mechanical failure.
- Inspect wiring for a short circuit that might be continuously activating the pump.
- Nefunkční LED indikátor:
- Verify the pump is actually running when the LED should be on.
- Check for loose connections to the LED.
- The LED itself might be faulty (though rare).
7. Uživatelské tipy
- Pravidelné testování: Always perform regular functional tests of your bilge pump system, especially before and after each use of your vessel, to ensure it is ready for emergencies.
- Správné těsnění: When installing, ensure all cable entries and mounting points are properly sealed with marine sealant to maintain the waterproof integrity of the panel and prevent water intrusion into your electrical system.
- Správa baterie: In manual mode, the pump runs continuously. Be mindful of your battery's charge level to avoid draining it completely.
- Ochrana proti přetížení: The switch is designed to prevent impact from intermittent high current. However, always ensure your bilge pump circuit has appropriate fusing or an overload protector installed as per marine electrical standards.
8. Záruka a podpora
For warranty information, technical support, or service inquiries, please contact your point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.
Tento výrobek má certifikaci CE, což potvrzuje shodu s evropskými požadavky na bezpečnost, ochranu zdraví a životní prostředí.