ACREL ACR10R

Návod k obsluze obousměrného solárního měřiče energie Acrel ACR10R

Model: ACR10R

1. Úvod

The Acrel ACR10R is a single-phase LCD DIN rail energy meter designed for precise power monitoring in grid-connected PV power stations and general power management applications. This meter is cost-effective and features easy installation without the need to remove the primary bus bar. It is capable of measuring various electrical parameters including current, voltage, active power, reactive power, frequency, and power factor. Additionally, it supports multi-tariff energy metering and 4-quadrant energy metering.

Acrel ACR10R Meter with highlighted features
Figure 1: Acrel ACR10R Meter with key features.

Klíčové vlastnosti:

  • Měření: 1-phase Active Power, Reactive Power, Current, Voltage atd.
  • Aktuální hodnocení: Available with external CTs for various diameters and current ratings (e.g., 16mm/120A, 24mm/200A, 36mm/300A).
  • Sdělení: RS485 (MODBUS-RTU) protocol.
  • Aplikace: Suitable for distributed Solar PV and anti-reflux inverter systems.
  • Zobrazit: LCD displej.
  • Instalace: 35mm DIN Rail.
  • Napájení: 85~265V AC or 100~350V DC.
  • Standard & Certificate: CE certifikováno.

2. Nastavení a instalace

2.1 Instalace na DIN lištu

The ACR10R meter is designed for easy installation on a standard 35mm DIN rail. Follow these steps:

  1. Push off the buckle on the back side of the meter.
  2. Install the 35mm DIN rail onto the slot behind the meter.
  3. Buckle up the meter to securely fix it on the DIN rail.
  4. Ensure the meter is successfully installed and stable.
Steps for DIN rail installation
Figure 2: Step-by-step guide for 35mm DIN rail installation.

2.2 Schéma zapojení a připojení

Důležité bezpečnostní upozornění: Make sure the AC cable is totally isolated from AC power before connecting the Meter and Current Transformer (CT). Incorrect connection or direction will cause incorrect data and potential hazards.

The ACR10R supports single-phase two-wire connections with external split core CTs. The meter is suitable for RS485 cable connection on the RJ45 port of Sermatec hybrid inverters.

Detailed wiring diagram for Acrel Single Phase Meter Installation
Figure 3: Detailed wiring diagram for the Acrel Single Phase Meter. Note the connections for L, N, S1, S2, and RS485 (A, B).

Current Transformer (CT) Installation:

The meter uses external split core CTs. Ensure the CT is correctly oriented according to the current flow direction. For split core CTs, connect S1 (Red) and S2 (Black) wires. For Rogowski coils, connect the Positive Electrode (Red) and Negative Electrode (White) as indicated.

Diagrams for installing Split Core CT and Rogowski coil
Figure 4: Installation diagrams for Split Core CT and Rogowski coil, showing wire connections and current direction.

Available Current Sensors (CTs):

The ACR10R is compatible with various external CTs to support different current ratings:

  • Vstup 80A: Max cable diameter 10mm.
    80A Current Transformer
    80A CT
  • Vstup 120A: Max cable diameter 16mm.
    120A Current Transformer
    120A CT
  • Vstup 200A: Max cable diameter 24mm.
    200A Current Transformer
    200A CT
  • Vstup 300A: Max cable diameter 36mm.
    300A Current Transformer
    300A CT
Video 1: Demonstration of connecting current transformers to the energy meter.

3. Návod k obsluze

LCD displej 3.1

The ACR10R features an LCD display that shows various measured parameters. The display provides clear readings of voltage, proud, výkon, energie, frekvence a účiník.

LCD Display of the Acrel ACR10R Meter
Figure 5: Close-up of the meter's LCD display.

3.2 Keypad HMI for Programming

The meter is equipped with a keypad Human-Machine Interface (HMI) for setting parameters and configuring communication settings. This includes:

  • Parameter Display Setting
  • Communication settings (address, baud rate, etc.)
Keypad HMI on the Acrel ACR10R Meter
Figure 6: Keypad HMI for programming and settings adjustment.

3.3 Bidirectional Metering

The ACR10R supports bidirectional metering, which is essential for distributed solar PV systems. It accurately measures both power consumption from the grid and redundant power generation fed back into the grid.

Diagram illustrating bidirectional metering
Figure 7: Bidirectional metering concept showing power consumption and redundant power generation.
Typical solar PV system with Acrel meter
Figure 8: Typical distributed solar PV system with the Acrel meter for monitoring.

4. Údržba

The Acrel ACR10R meter is designed for reliable operation with minimal maintenance. However, regular checks can ensure optimal performance and longevity:

  • Vizuální kontrola: Periodically inspect the meter and its connections for any signs of damage, loose wiring, or corrosion.
  • Čištění: Udržujte displej měřiče a casing clean using a soft, dry cloth. Avoid using abrasive cleaners or solvents.
  • Podmínky prostředí: Abyste předešli poškození, zajistěte, aby provozní prostředí zůstalo v rámci specifikovaného rozsahu teploty a vlhkosti.
  • Aktualizace firmwaru: Zkontrolujte výrobce webna webu, kde najdete dostupné aktualizace firmwaru, které mohou zlepšit výkon nebo přidat nové funkce.

Always disconnect power before performing any maintenance or inspection to prevent electric shock.

5. Řešení problémů

If you encounter issues with your Acrel ACR10R meter, consider the following troubleshooting steps:

  • Bez displeje/napájení: Check the power supply connections (AC85~265V or DC100~350V). Ensure the power source is active.
  • Nesprávné čtení:
    • Verify that the CTs are correctly installed and oriented according to the current flow direction (refer to Section 2.2).
    • Zkontrolujte všechna zapojení kabelů, zda nejsou uvolněná nebo nesprávně umístěna.
    • Ensure the meter's parameters (e.g., CT ratio) are correctly configured via the keypad HMI.
  • Problémy s komunikací (RS485):
    • Check the RS485 wiring for correct polarity (A and B connections).
    • Verify the communication settings (baud rate, address) on both the meter and the connected device (e.g., inverter).
    • Ensure the RS485 cable is properly connected to the RJ45 port if using Sermatec hybrid inverters.
  • Měřič nereaguje: Try power cycling the device (turn off, wait a few seconds, then turn on). If the issue persists, contact technical support.

Any fault or damage caused by misoperation or disregard of the instructions in this manual is beyond Acrel's warranty coverage.

6. Specifikace

KategorieParametrHodnota
VstupMřížkaJednofázové
Frekvence45~65Hz
svtageJmenovitý objemtage: AC 100V, 400V
Overload: 1.2 times rated voltage (continuous); 2 times for 1 second
Power consumption: less than 0.2VA
ProudRated current: 10A, 20A, 40A, 80A, 120A, 200A, 300A (depending on CT)
Overload: 1.2 times rated current (continuous); 10 times for 1 second
Power consumption: less than 0.2VA
VýstupSděleníRozhraní RS485, Modbus-RTU
ZobrazitLCD
Přesnost měřeníTřída přesnostisvtage: 0.2 level, Current/Active Energy: 0.5 level, Frequency: 0.01Hz, Reactive Energy: 1 level
Napájenísvtage DosahAC85~265V or DC100~350V; Power consumption ≤10VA
BezpečnostVýkonová frekvenční výdrž objtageAC2kV 1 min between power supply // current input // voltage input and communication; AC2kV 1 min between each pair of combinations
Izolační odporInput, output terminal to housing >100MΩ
ProstředíProvozní teplota-10℃~+55℃
Skladovací teplota-20℃~+70℃
Relativní vlhkost5% ~ 95%, nekondenzující
Nadmořská výška≤2500 m
RozměryVelikost (D*Š*V)85 * 64 * 54 mm
Rozsah měření energieEnergetický rozsah0–10 000 kWh
OsvědčeníNormaCE
Dimensions of the Acrel ACR10R Meter
Figure 9: Dimensions of the Acrel ACR10R meter.
CE Certificate for ACR (AC Network Multi-functional Power Meters)
Figure 10: CE Certificate for ACR (AC Network Multi-functional Power Meters).

7. Uživatelské tipy

Z poskytnutých informací nebyly k dispozici žádné konkrétní tipy pro uživatele.views or Q&A content. However, general best practices for energy meters include:

  • Always ensure proper grounding to prevent electrical hazards.
  • Regularly check the meter's readings against other known values (if available) to confirm accuracy.
  • Keep the meter's software updated if new versions are released by the manufacturer.

8. Záruka a podpora

The Acrel ACR10R is manufactured by ACREL, a reputable brand in electrical measurement. For any technical assistance, warranty claims, or support, please contact the official Acrel support channels or your authorized dealer. Ensure you retain your purchase records for warranty purposes.


Měřič energie Acrel ACR10R-D161E4 s Rogowského cívkami pro měření výkonu

Měřič energie Acrel ACR10R-D161E4 s Rogowského cívkami pro měření výkonu

0:45 • 960×540 • vizuální_překrytíview

Související dokumenty - ACR10R-D161E4

Předview Acrel ACR10R Multifunkční elektrický přístroj kolejnicového typu s externím proudovým transformátorem s děleným jádrem - Návod k použití a instalaci
This manual provides comprehensive instructions for the Acrel ACR10R series rail-type multifunction electrical instrument, including its specifications, functions, installation, programming, and RS485 MODBUS-RTU communication. It details technical parameters, connection modes, operation procedures, and troubleshooting guidance for industrial and commercial power monitoring applications.
Předview Inteligentní měřič Acrel ADL3000-E: Instalační a provozní manuál
Komplexní návod k instalaci a provozu inteligentního měřiče Acrel ADL3000-E, který zahrnuje technické specifikace, zapojení, funkce displeje a komunikační protokoly.
Předview Acrel D317 Rail-type Multifunction Electrical Instrument with External Split Core Current Transformer: Use and Installation Manual
Comprehensive use and installation manual for the Acrel D317 Rail-type Multifunction Electrical Instrument, featuring an external split-core current transformer. Details technical specifications, product functions, installation procedures, and communication protocols for industrial energy monitoring applications.
Předview Návod k instalaci a provozu jednofázového elektroměru ADL100-ET
Komplexní návod k instalaci a obsluze jednofázového elektroměru Acrel ADL100-ET. Tento návod podrobně popisuje technické specifikace, funkční popisy, pokyny k zapojení, nabídky displeje, programovací postupy a komunikační protokoly (Modbus RTU).
Předview DJSF1352-RN Rail-Mounted DC Power Meter Installation and Operation Manual
This document provides comprehensive installation and operation instructions for the Acrel DJSF1352-RN rail-mounted DC power meter. It covers product specifications, technical parameters, wiring diagrams, operational guidance, menu settings, and communication protocols (Modbus-RTU, DLT645-07).
Předview Acrel D318 Harmonic Meter Operation Instruction Manual
Operation instruction manual for the Acrel D318 External Roche Coil and Switched Transformer Harmonic Meter. Details features, technical specifications, and connection methods for energy saving and power monitoring applications.