The Ranco RDTB-3210B is a sophisticated digital control unit designed for refrigeration applications. It serves as an enhanced alternative to the Eliwell ID974, offering improved performance and reliability. This unit is equipped with two NTC sensors and three powerful relays to manage compressor, defrost, and fan operations, ensuring precise temperature control and efficient system management.

2. Klíčové vlastnosti

  • Powerful Relays: Nabízí 20 Ampere relay for compressor startup, a 10 Ampere relay for the defrost heater, and a 5 Ampere relay for the fan.
  • Dual Voltage Operace: Compatible with both 220V and 110V AC mains voltage at 50 Hz, making it suitable for various installations, including marine applications.
  • Vysoká kvalita: Manufactured with impeccable Czech quality in assembly and components.
  • Intuitivní rozhraní: Designed for ease of use with a clear display and straightforward button controls.
  • NTC Sensors: Includes two NTC temperature sensors for accurate temperature monitoring.

3. Obsah balení

Po vybalení se prosím ujistěte, že jsou přítomny všechny položky:

  • 1 x Ranco RDTB-3210B Control Unit
  • 2 x NTC Temperature Sensors

4. Specifikace

ParametrHodnota
ModelRDTB-3210B
TypŘídicí jednotka
AplikaceChladicí systémy
Relé kompresoru20A (resistive load) / 10A (inductive load) @ 250V~
Odmrazovací relé10A (resistive load) / 5A (inductive load) @ 250V~
Relé ventilátoru5A (resistive load) / 2A (inductive load) @ 250V~
Napájení110V / 220V AC, 50 Hz
Spotřeba energie4.5 W max (4.5 VA max)
Senzory zahrnuty2 x NTC Probes
Teplotní rozsah sondy-5 °C až 50 °C
Šířka těla75 mm
Hloubka těla85 mm
Výška těla34 mm

5. Nastavení a instalace

Důležité: Ensure that the main power supply is disconnected before performing any installation or wiring to prevent electric shock or damage to the unit.

5.1 Rozměry

The RDTB-3210B control unit is designed for panel mounting. Refer to the diagram below for precise dimensions.

Ranco RDTB-3210B Control Unit Dimensions
Figure 1: RDTB-3210B Control Unit Dimensions (Width: 75mm, Depth: 85mm)

5.2 Schéma zapojení

Carefully follow the wiring diagram provided on the unit's label and illustrated below. All connections should be made by a qualified technician.

Ranco RDTB-3210B Control Unit Wiring Diagram
Figure 2: RDTB-3210B Control Unit Wiring Diagram and Front View

Připojení terminálu:

  • Terminály 1 a 2: Power Supply (Connect to 230VAC or 110VAC, 50Hz).
  • Terminály 3 a 4: Compressor Output (Normally Open contact, rated for 20A resistive / 10A inductive at 250V~).
  • Terminály 5 a 6: Defrost Output (Normally Open contact, rated for 10A resistive / 5A inductive at 250V~).
  • Terminály 7 a 8: Fan Output (Normally Open contact, rated for 5A resistive / 2A inductive at 250V~).
  • Terminály 9 a 10: NTC Probe Inputs (Connect the two NTC sensors, labeled P1 and P2).
  • Ho.Key: Hot Key Port (For quick programming or data transfer, refer to advanced documentation if applicable).

Ensure all connections are secure and correctly insulated. Mount the unit in a location protected from moisture and excessive vibration.

6. Návod k obsluze

The RDTB-3210B features an intuitive interface for easy operation. After proper installation and power-up, the display will show the current temperature reading from the primary NTC sensor.

6.1 Tlačítka

  • SOUBOR: Used to enter parameter setting mode or confirm a value.
  • PgUp (Up Arrow): Používá se ke zvyšování hodnot nebo navigaci v možnostech nabídky.
  • PgDn (Down Arrow): Používá se ke snížení hodnot nebo navigaci v možnostech nabídky.

6.2 Základní obsluha

  1. ViewNastavení požadované hodnoty: Briefly press the SET button to view the current temperature setpoint.
  2. Changing Setpoint: Press and hold the SET button for a few seconds until the setpoint value flashes. Use the PgUp/PgDn buttons to adjust the value, then press SET again to confirm.
  3. Přístup k parametrům: To access advanced parameters, typically a longer press of the SET button or a combination of buttons is required. Refer to the detailed programming guide (usually provided with the unit) for specific parameter codes and their functions.

7. Údržba

Regular maintenance ensures the longevity and optimal performance of your RDTB-3210B control unit.

  • Čištění: Periodically clean the unit's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no dust or debris accumulates around the ventilation openings.
  • Kontrola připojení: Annually, or as needed, verify that all electrical connections are secure and free from corrosion.
  • Kontrola senzoru: Check the NTC sensors for any physical damage or signs of wear. Ensure they are properly positioned for accurate temperature readings. Replace faulty sensors promptly.
  • Podmínky prostředí: Ensure the unit is operating within its specified environmental conditions (temperature, humidity) to prevent premature failure.

8. Řešení problémů

If you encounter issues with your RDTB-3210B control unit, refer to the following common troubleshooting steps:

  • Žádný displej/Žádné napájení:
    • Zkontrolujte hlavní napájení jednotky.
    • Verify that terminals 1 and 2 are correctly wired and receiving the specified voltage (110V or 220V AC).
    • Inspect the fuse (if external) for the control circuit.
  • Nesprávný údaj teploty:
    • Ensure NTC sensors are correctly connected to terminals 9 and 10.
    • Check the physical placement of the sensors; they should be in the area where temperature needs to be measured accurately.
    • Inspect sensor cables for damage. A faulty sensor will typically display an error code (e.g., 'P1' or 'P2' error, 'E1', 'E2').
  • Compressor/Defrost/Fan Not Activating:
    • Verify that the setpoint and differential parameters are correctly configured.
    • Check the wiring to the respective loads (compressor, defrost heater, fan) at terminals 3-4, 5-6, and 7-8.
    • Ensure the loads themselves are functional.
    • If the unit displays an alarm code, consult the full programming manual for its meaning.

For persistent issues or complex problems, it is recommended to consult a qualified refrigeration technician.

9. Uživatelské tipy

  • Optimální umístění senzoru: For the most accurate temperature control, ensure your NTC sensors are placed in locations that truly represent the temperature of the controlled environment, away from direct airflow or heat sources that could skew readings.
  • Zálohování parametrů: Before making significant changes to advanced parameters, it's good practice to note down the original settings. This allows for easy restoration if unintended behavior occurs.

10. Záruka a podpora

Pro informace o záruce, technickou podporu nebo servisní dotazy se prosím obraťte na místo, kde jste výrobek zakoupili, nebo na autorizované servisní středisko výrobce. Uschovejte si účtenku jako doklad o koupi.

Související dokumenty - RDTB-3210B

Předview Katalog chladicích řídicích jednotek Ranco, Johnson Controls a Danfoss
Komplexní katalog regulátorů teploty a tlaku Ranco, Johnson Controls a Danfoss, včetně regulátorů nízkého tlaku, regulátorů vysokého a nízkého tlaku, elektronických regulátorů, regulátorů odmrazování a příslušenství pro chladicí systémy.
Předview Ranco ETC Two Stage Elektronická regulace teploty - instalační data NEMA typ 4X
Instalační data, specifikace, provoz a řešení problémů pro Ranco ETC Two Stage Elektronická regulace teploty, NEMA typ 4X. Tato regulace je určena pro komerční vytápění, větrání a klimatizaci a chlazení a nabízí dvojítagRegulace teploty, LCD displej, programování pomocí klávesnice a vodotěsné pouzdro NEMA 4X pro venkovní použití.
Předview Ranco ETC Single Stage Electronic Temperature Control Installation Instructions
Comprehensive installation, operation, and troubleshooting guide for the Ranco ETC Single Stage Electronic Temperature Control. Covers product details, applications, features, specifications, ordering, programming, lockout switch, wiring diagrams, and sensor information for HVAC and refrigeration systems.
Předview Ranco O12/O22 Dual Pressure Controls Installation Data
Installation guide for Ranco O12/O22 dual pressure controls, covering description, application, installation, wiring, and adjustments for commercial refrigeration and air conditioning systems.
Předview Instalační data pro jednotlivá tlaková regulace Ranco
Instalační data pro tlakové regulátory Ranco s jedním regulátorem (010, 011, 016, 020). Zahrnují popis, použití, instalaci, zapojení a nastavení regulace pro různá chladiva a tlakové rozsahy.
Předview Ranco O10/O11/O16/O20 Single Pressure Control Installation Data
Comprehensive installation data, wiring, settings, and specifications for Ranco O10, O11, O16, and O20 single pressure controls used in commercial refrigeration and air conditioning systems. Includes mounting instructions, capillary care, control wiring, adjustment procedures, and detailed specifications.