1. Úvod
This manual provides detailed instructions for the installation, operation, and maintenance of your Sinotimer Digital Analogue DIN Module Time Switch. This device is designed for industrial applications, offering precise 24-hour programmable timing with a large LCD display and backlight functionality.
2. Funkce produktu
- Clock display (24-hour format).
- Programmable Timer with up to 96 ON/OFF programs per day.
- Backlight feature: The backlight illuminates when the timer is off and automatically disappears after 5 seconds.
3. Specifikace
| Parametr | Hodnota |
|---|---|
| Čísla modelů | TM929AKL (16A), TM929BKL (30A) |
| Napájení | 85~265VAC, 50/60Hz |
| Max. Current of Output Load | 16 A / 30 A (v závislosti na modelu) |
| Programy | Up to 96 ON/OFF per day |
| Rozsah nastavení | 15 minut až 24 hodin |
| Minimální interval nastavení | 15 minut |
| Zobrazit | LCD s podsvícením |
| Rozměry | 86.5 mm x 36 mm x 68.5 mm |
| Instalace | 35 mm DIN lišta |
| Baterie | TM929AKL (16A): Replaceable CR2032; TM929BKL (30A): Non-replaceable internal battery |
| Spotřeba energie | <5VA |
| Black-out (Power Reserve) | 90 dní |
| Osvědčení | CE |
Poznámka: The TM929AKL (16A) model features a replaceable CR2032 battery, while the TM929BKL (30A) model has a non-replaceable internal battery. Wiring diagrams differ between models.

4. Nastavení
4.1 Instalace
The time switch is designed for mounting on a standard 35mm DIN rail. Ensure the mounting location is dry, well-ventilated, and free from excessive vibrations or extreme temperatures.

4.2 Zapojení
VAROVÁNÍ: All wiring should be performed by a qualified electrician and in accordance with local electrical codes. Ensure power is disconnected before attempting any wiring.
The timer has terminals for Line (L), Neutral (N), and output contacts (NO, NC, Common). Refer to the diagrams below for typical wiring configurations.


4.3 Počáteční zapnutí
Once wired correctly, apply power to the device. The LCD will illuminate and display the current time. If the display is blank, check the power supply and, for the 16A model, ensure the CR2032 battery is correctly installed.
5. Návod k obsluze
The timer features a MENU button, UP/DOWN arrow buttons, an OK button, and a Reset (Res) button.

5.1 Nastavení aktuálního času
- Press the 'MENU' button.
- Use the 'UP' and 'DOWN' arrow buttons to adjust the hour and minute.
- Press 'OK' to confirm each setting.
- Press 'MENU' again to return to the clock display.
5.2 Programování cyklů ZAP/VYP
The timer supports up to 96 ON/OFF programs. Each program can be set for specific days of the week.
- Press the 'MENU' button to enter programming mode. The display will show '00:00' or a program number.
- Use 'UP' and 'DOWN' to set the desired ON time (hour and minute). Press 'OK' to confirm.
- Next, set the desired OFF time (hour and minute). Press 'OK' to confirm.
- Use 'UP' and 'DOWN' to select the days of the week for this program (e.g., Mon-Fri, Sat-Sun, or individual days). Press 'OK' to confirm.
- Repeat steps 2-4 for additional programs.
- Press 'MENU' to exit programming mode and save settings.
5.3 Ruční ovládání
To manually switch the timer's output, press the 'OK' button. This will cycle through the modes: ON (always on), AUTO (follows programmed schedule), and OFF (always off).
6. Údržba
6.1 Battery Replacement (TM929AKL 16A only)
The TM929AKL (16A) model uses a replaceable CR2032 battery. If the display becomes dim or the time settings are lost frequently during power outages, the battery may need replacement. Carefully open the battery compartment and replace the CR2032 battery, ensuring correct polarity. The TM929BKL (30A) model has a non-replaceable internal battery.
6.2 Obecná péče
Keep the device clean and dry. Use a soft, dry cloth for cleaning. Avoid using abrasive cleaners or solvents. Ensure the protective cover is closed to prevent dust and moisture ingress.
7. Řešení problémů
- Displej je prázdný: Check the main power supply. For the 16A model, check the CR2032 battery.
- Timer not switching: Verify wiring connections are secure and correct. Ensure the timer is in 'AUTO' mode. Check that programs are set correctly and not conflicting.
- Nesprávný čas: Reset the timer using the 'Res' button and reprogram the current time.
- Programy se nespouštějí: Ensure the timer is in 'AUTO' mode. Check that the ON/OFF times and days are correctly set.
7.1 Resetování časovače
To perform a full reset, press the 'Res' button (usually a small recessed button requiring a pointed object like a pen tip). This will clear all settings and return the timer to its factory default state. You will need to reprogram the current time and all desired ON/OFF cycles.
8. Uživatelské tipy
- For precise control, utilize the full capacity of 96 ON/OFF programs to manage complex schedules.
- When setting intervals, remember the minimum programmable interval is 15 minutes.
- Always double-check your wiring before applying power to prevent damage to the unit or connected appliances.
9. Záruka a podpora
For technical assistance, warranty claims, or further information, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.