Omada L3 Campus Stackable Managed Switch User Manual

Omada L3 Campus Stackable Managed Switch

L3 Campus Stackable Managed Switch

Specifikace

  • Model: Omada Campus Stackable L3 Managed Switch
  • Front Panel: Mode Selection Button, Management Port, LED,
    Console Port USB2.0 Port (Type-C/RJ45), 1G RJ45 Port, 10G SFP+ Slot
    LED
  • LED indikace:
    • PWR1*: Green On (switch powered by PWR1), Off (PWR2
      disconnected or not working properly)
    • PWR2: Green On (switch powered by PWR1 and PWR2 connected),
      Yellow On** (PWR2 powered), Off (PWR1 disconnected or not working
      správně)
    • LED SYS FAN: Green On (all fans work properly), Yellow On (not
      all fans work properly)
    • MGMT: On (device linked to port), Flashing (transmitting or
      receiving data), Off (no device linked to port)
    • MST: On (device linked to port), Flashing (transmitting or
      receiving data), Off (no device linked to port)

Návod k použití produktu

Kapitola 2: Instalace

Před zahájením procesu instalace se ujistěte, že máte vše
the necessary tools and follow safety precautions.

  • Obsah balení: Check all items mentioned in
    balíček.
  • Bezpečnostní opatření: Follow the guidelines to
    zajistit bezpečnou instalaci.
  • Instalační nástroje: Gather all tools required
    pro instalaci.
  • Instalace produktu: Postupujte krok za krokem
    instructions provided in the manual for successful
    instalace.

Kapitola 3: Připojení

After installation, connect the switch to the network using
appropriate cables and ports as per your network setup.

Kapitola 4: Konfigurace

Configure the switch based on your requirements. You can choose
between Standalone Mode or Controller Mode as per your network
potřeby.

FAQ

Q: What should I do if the LED indications show an error?

A: If the LED indications suggest improper functioning, check
the power sources and connections. Refer to the troubleshooting
části v příručce pro další pomoc.

Loading PDF…
Download PDF

Řešení podnikových sítí
Průvodce instalací
Omada C.ampus Stackable L3 Managed Switch

O této instalační příručce
Tato instalační příručka popisuje hardwarové vlastnosti, metody instalace a body, kterým je třeba během instalace věnovat pozornost. Tato instalační příručka je strukturována následovně: Kapitola 1 Úvod Tato kapitola popisuje externí komponenty přepínače. Kapitola 2 Instalace Tato kapitola ukazuje, jak přepínač nainstalovat. Kapitola 3 Připojení Tato kapitola ukazuje, jak provést fyzické připojení přepínače. Kapitola 4 Konfigurace Tato kapitola ukazuje, jak přepínač nakonfigurovat. Dodatek A Řešení problémů Dodatek B Specifikace

Publikum

Tato instalační příručka je určena pro:

Síťový inženýr

Správce sítě

Konvence
· Některé modely uvedené v této příručce nemusí být ve vaší zemi nebo regionu k dispozici. Informace o místním prodeji naleznete na adrese https://www.omadanetworks.com/.
· Obrázky v kapitole 2, kapitole 3 a kapitole 4 jsou pouze pro demonstrační účely. Váš spínač se může vzhledově lišit od vyobrazeného.
· Výpočty rozpočtu PoE jsou založeny na laboratorních testech. Skutečný rozpočet napájení PoE není zaručen a bude se lišit v důsledku omezení klienta a faktorů prostředí.
· Tato příručka používá specifické formáty ke zvýraznění speciálních zpráv. V následující tabulce jsou uvedeny ikony upozornění, které se používají v této příručce.

Připomeňte, že buďte opatrní. Varování označuje potenciál, který může vést k poškození zařízení.
Připomeňte si všímat. Poznámka obsahuje užitečné informace pro lepší využití produktu.

Související dokument
Uživatelská příručka a referenční příručka k produktu CLI jsou k dispozici na stránce Download Center. Chcete -li získat nejnovější informace o produktu, navštivte oficiální stránky webstránky: https://support.omadanetworks.com/document/.

Obsah
Kapitola 1 Úvod ———————- 01
1.1 Konec produktuview …………………………………………………………..01 1.2 Vzhled…………………………………………………………………………..01
Kapitola 2 Instalace ———————- 12
2.1 Obsah balení …………………………………………………………….12 2.2 Bezpečnostní opatření ……………………………………………………………12 2.3 Instalační nástroje…………………………………………………………………..14 2.4 Instalace produktu …………………………………………………………..14
Kapitola 3 Připojení ———————- 22
3.1 Ethernet Port …………………………………………………………..22 3.2 10G SFP+/25G SFP28/100G QSFP28 Slot ………..22 3.3 Console Port ……………………………………………………………22 3.4 Verify Installation…………………………………………………….23 3.5 Power On ………………………………………………………………….24 3.6 Initialization………………………………………………………………24 3.7 Stack Topology ……………………………………………………….24
Kapitola 4 Konfigurace ——————– 27
4.1 Konfigurace přesview…………………………………………………27 4.2 Samostatný režim… ...
Dodatek A Řešení problémů —————- 32
Dodatek B Specifikace —————— 33

Omada C.ampus Stackable L3 Managed Switch

Kapitola 1 Úvod

1.1 Konec produktuview
Navrženo pro podniky a campus, Omada Campus Stackable L3 Managed Switch provides wire-speed performance and abundant L2 and L3 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. Static Routing, RIP, OSPF, BGP, IS-IS, PIM-SM/DM/SSM, and ECMP come with abundant Layer 3 routing protocols that support a scalable network. Physically stacking for builtin redundancy and performance. Redundant power supplies and fans make it an ideal choice for reliable networking architecture. VRRP allows a group of switches to dynamically back up each other. ERPS supports rapid protection and recovery in a ring topology. MACsec, secure boot, ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB, Netconf and CLI Log-in bring abundant management policies. These switches integrate multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance. S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is also a Power Sourcing Equipment (PSE*). The RJ45 ports that support Power over Ethernet (PoE*) function can automatically detect and supply power to those powered devices (PDs*) complying with IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt (only for S6500-24MPP4Y/S6500-48MPP6Y). *PSE: a device (switch or hub for instance) that provides power through an Ethernet cable. *PoE: This technology describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet. *PD: a device powered by a PSE and thus consumes energy. Exampzahrnují napájení síťových kamer, bezdrátových přístupových bodů LAN, IP telefonů, síťových rozbočovačů, vestavěných počítačů atd.
1.2 Vzhled
Front Panel (The figure is for demonstration only. It may differ from your actual product. )
The front panel of S6500-24G4XF is shown as the following figure.
Tlačítko pro výběr režimu
Port pro správu

LED

Console Port USB2.0 Port (Type-C/RJ45)

Port 1G RJ45

10G SFP+ Slot LED

The front panel of S6500-48G6XF is shown as the following figure.
Tlačítko pro výběr režimu
Port pro správu

LED

Console Port USB2.0 Port (Type-C/RJ45)

Port 1G RJ45

10G SFP+ Slot LED

Úvod 01

Omada C.ampus Stackable L3 Managed Switch

LED indikace

PWR1*

PWR2

Zelená svítí

Vypnuto

Zelená svítí

Žlutá zapnutá**

Vypnuto

Zelená svítí

Vypnuto

Vypnuto

Indikace
Přepínač je napájen PWR1. PWR2 je odpojený nebo nefunguje správně.
Přepínač je napájen PWR1. PWR1 a PWR2 jsou propojeny.*
Přepínač je napájen PWR2. PWR1 je odpojený nebo nefunguje správně.
Vypínač je vypnutý nebo oba PWR1 a PWR2 nefungují správně.

LED SYS FAN
MGMT
MST
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(When the SPEED LED is on)
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(Když svítí LED STK)
Port 25-28 of S6500-24G4XF/ Port 49-54 of S6500-48G6XF ***

Indikace
Bliká: Přepínač funguje správně. Zapnuto nebo Vypnuto: Přepínač nefunguje správně.
Zelená Svítí: Všechny ventilátory fungují správně. Žlutá Svítí: Ne všechny ventilátory fungují správně.
Svítí: Zařízení je připojeno k portu. Bliká: Probíhá přenos nebo příjem dat. Nesvítí: K portu není připojeno žádné zařízení.
Zapnuto: Zařízení funguje jako hlavní přepínač v topologii zásobníku nebo pracuje samostatně. Vypnuto: Zařízení funguje jako členský přepínač v topologii zásobníku.
Zelená Svítí: Běží rychlostí 1000 Mb/s, ale žádná aktivita. Zelená Bliká: Běží rychlostí 1000 Mb/s a vysílá nebo přijímá data. Žlutá Svítí: Běží rychlostí 10 Mb/s/100 Mb/s, ale žádná aktivita. Žlutá Bliká: Běží rychlostí 10 Mb/s/100 Mb/s a vysílá nebo přijímá data. Nesvítí: K odpovídajícímu portu není připojeno žádné zařízení.
On: Číslo portu udává ID jednotky v topologii zásobníku.
Zelená Svítí: Běží rychlostí 10 Gb/s, ale žádná aktivita. Zelená Bliká: Běží rychlostí 10 Gb/s a vysílá nebo přijímá data. Žlutá Svítí: Běží rychlostí 1 Gb/s, ale žádná aktivita. Žlutá Bliká: Běží rychlostí 1 Gb/s a vysílá nebo přijímá data. Nesvítí: K odpovídajícímu portu není připojeno žádné zařízení.

*PWR1 is the primary power supply and it takes priority over PWR2. When the device is powered by PWR1, PWR2 will be working in the backup mode.
**Pokud oba PWR1 a PWR2 fungují správně a spínač je napájen PWR1, trvá 10-20 sekund, než LED PWR2 (žlutá) zhasne po odpojení PWR2.
***All 10 Gbps SFP+ slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.

02 Úvod

Omada C.ampus Stackable L3 Managed Switch The front panel of S6500-24GP4XF is shown as the following figure.

Tlačítko pro výběr režimu
Port pro správu
LED Console Port USB2.0 Port (Type-C/RJ45)

Port 1G RJ45

10G SFP+ Slot LED

Přední panel S6500-48GP6XF je zobrazen jako následující obrázek.

Tlačítko pro výběr režimu
Port pro správu
LED Console Port USB2.0 Port (Type-C/RJ45)

Port 1G RJ45

10G SFP+ Slot LED

The front panel of S6500-24M4Y is shown as the following figure.

Tlačítko pro výběr režimu
Port pro správu
LED Console Port USB2.0 Port (Type-C/RJ45)

Port 2.5G RJ45

25G SFP28 Slot LED

The front panel of S6500-24MPP4Y is shown as the following figure.

Tlačítko pro výběr režimu
Port pro správu
LED Console Port USB2.0 Port (Type-C/RJ45)

Port 2.5G RJ45

25G SFP28 Slot LED

Úvod 03

Omada C.ampus Stackable L3 Managed Switch The front panel of S6500-48M6Y is shown as the following figure.

Tlačítko pro výběr režimu
Port pro správu

LED Console Port USB2.0 Port (Type-C/RJ45)

Port 2.5G RJ45

The front panel of S6500-48MPP6Y is shown as the following figure.

25G SFP28 Slot LED

Tlačítko pro výběr režimu
Port pro správu
LED Console Port USB2.0 Port (Type-C/RJ45)

Port 2.5G RJ45

25G SFP28 Slot LED

LED Indication LED
PWR1* PWR2
SYS FAN PoE MAX
(For S6500-24GP4XF, S6500-48GP6XF, S6500-24MPP4Y, S6500-48MPP6Y)
MGMT
MST

Indikace
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Bliká: Přepínač funguje správně. Zapnuto nebo Vypnuto: Přepínač nefunguje správně.
Zelená Svítí: Všechny ventilátory fungují správně. Žlutá Svítí: Ne všechny ventilátory fungují správně.
Svítí: Zbývající výkon PoE je 7 W. Bliká: Zbývající napájení PoE zůstává 7 W poté, co tato LED svítí po dobu 2 minut. Nesvítí: Zbývající napájení PoE je > 7 W.
Svítí: Zařízení je připojeno k portu. Bliká: Probíhá přenos nebo příjem dat. Nesvítí: K portu není připojeno žádné zařízení.
Zapnuto: Zařízení funguje jako hlavní přepínač v topologii zásobníku nebo pracuje samostatně. Vypnuto: Zařízení funguje jako členský přepínač v topologii zásobníku.

04 Úvod

Omada C.ampus Stackable L3 Managed Switch

LED

Indikace

Port 1-24 of S6500-24GP4XF/
Port 1-48 of S6500-48GP6XF
(When the SPEED LED is on)

Zelená Svítí: Běží rychlostí 1000 Mb/s, ale žádná aktivita. Zelená Bliká: Běží rychlostí 1000 Mb/s a vysílá nebo přijímá data. Žlutá Svítí: Běží rychlostí 10 Mb/s/100 Mb/s, ale žádná aktivita. Žlutá Bliká: Běží rychlostí 10 Mb/s/100 Mb/s a vysílá nebo přijímá data. Nesvítí: K odpovídajícímu portu není připojeno žádné zařízení.

Port 1-24 of S6500-24M4Y & S6500-24MPP4Y/
Port 1-48 of S6500-48M6Y & S6500-48MPP6Y
(When the SPEED LED is on)

Green On: Running at 2.5 Gbps, but no activity. Green Flashing: Running at 2.5 Gbps and transmitting or receiving data. Yellow On: Running at 10 Mbps/100 Mbps/1000 Mbps, but no activity. Yellow Flashing: Running at 10 Mbps/100 Mbps/1000 Mbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

Port 1-24 of S6500-24GP4XF, S6500-24M4Y &
S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF, S6500-48M6Y &
S6500-48MPP6Y
(Když svítí LED STK)

On: Číslo portu udává ID jednotky v topologii zásobníku.

Port 1-24 of S6500-24GP4XF & S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF & S6500-48MPP6Y
(Když svítí PoE LED)

Green On: The port is supplying power normally. Green Flashing: The supply power exceeds the correponding port’s maximum power. Yellow On: Overload or short circuit is detected. Off: Not providing PoE power on the port

Port 25-28 of S6500-24GP4XF/ Port 49-54 of S6500-48GP6XF ***

Zelená Svítí: Běží rychlostí 10 Gb/s, ale žádná aktivita. Zelená Bliká: Běží rychlostí 10 Gb/s a vysílá nebo přijímá data. Žlutá Svítí: Běží rychlostí 1 Gb/s, ale žádná aktivita. Žlutá Bliká: Běží rychlostí 1 Gb/s a vysílá nebo přijímá data. Nesvítí: K odpovídajícímu portu není připojeno žádné zařízení.

Port 25-28 of S6500-24M4Y & S6500-24MPP4Y/
Port 49-54 of S6500-48M6Y & S6500-48MPP6Y***

Zelená svítí: Zařízení pracuje rychlostí 25 Gb/s, ale bez aktivity. Zelená bliká: Zařízení pracuje rychlostí 25 Gb/s a vysílá nebo přijímá data. Žlutá svítí: Zařízení pracuje rychlostí 1 Gb/s/10 Gb/s, ale bez aktivity. Žlutá bliká: Zařízení pracuje rychlostí 1 Gb/s/10 Gb/s a vysílá nebo přijímá data. Nesvítí: K odpovídajícímu portu není připojeno žádné zařízení.

*By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, S6500-24M4Y/S650048M6Y is shipped with a PSM550-AC power supply module, and S6500-48GP6XF/S6500-24MPP4Y/ S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately.
**By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode: for S6500-24GP4XF/S6500-48GP6XF/S650024MPP4Y/S6500-48MPP6Y, you can specify the primary power supply and the backup power supply according to your needs; for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
***All 10 Gbps SFP+ slots and 25 Gbps SFP28 slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.

Úvod 05

Omada C.ampus Stackable L3 Managed Switch The front panel of S7500-26XF6Y is shown as the following figure.
Port pro správu

LED

Console Port USB3.0 Port

(RJ45/typ C)

Výběr režimu

Tlačítko

10G SFP+ Slot (Port 1-26)

The front panel of S7500-48XF4C is shown as the following figure.

LED 25G SFP28 Slot (Port 27-32)

Tlačítko pro výběr režimu
Port pro správu
LED Console Port USB3.0 Port (Type-C/RJ45)

10G SFP+ Slot (Port 1-48)

The front panel of S7500-24Y4C is shown as the following figure.

100G QSFP28 Slot LED (Port 49-52)

Port pro správu

LED

Port USB 3.0

Konzolový port

(RJ45/typ C)

Tlačítko pro výběr režimu

Slot 25G SFP28

LED

(Port 1-24)

The front panel of S7500-48Y8C is shown as the following figure.

Slot 100G QSFP28 (port 25-28)

LED Mode Selection Button

25G SFP28 Slot (Port 1-48)

06 Úvod

Slot 100G QSFP28 (port 49-56)

Omada C.ampus Stackable L3 Managed Switch The front panel of S7500-32C is shown as the following figure.

Tlačítko pro výběr režimu
LED dioda řídicího portu
Port USB 3.0

Console Port (Type-C/RJ45)

100G QSFP28 slot

LED

Note: S7500-24Y4C and S7500-48Y8C are designed for installation in Network Telecommunications Facilities (NTFs) where ambient temperature and humidity are controlled.

LED Indication LED
PWR1* PWR2
SYSTÉMOVÝ VENTILÁTOR
MGMT
MST
Port 1-26 of S7500-26XF6Y/ Port 1-48 of S7500-48XF4C
(Když svítí LED dioda SPD)
Port 1-24 of S7500-24Y4C/ Port 1-48 of S7500-48Y8C
(When the SPD/SPEED LED is on)

Indikace
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Bliká: Přepínač funguje správně. Zapnuto nebo Vypnuto: Přepínač nefunguje správně.
Zelená: Všechny ventilátory fungují správně. Žlutá: Ne všechny ventilátory fungují správně.
Svítí: Zařízení je připojeno k portu. Bliká: Probíhá přenos nebo příjem dat. Nesvítí: K portu není připojeno žádné zařízení.
Poznámka:
For S7500-48Y8C, this LED lights green at 1 Gbps and orange at sub-1 Gbps.
Zapnuto: Zařízení funguje jako hlavní přepínač v topologii zásobníku nebo pracuje samostatně. Vypnuto: Zařízení funguje jako členský přepínač v topologii zásobníku.
Zelená Svítí: Běží rychlostí 10 Gb/s, ale žádná aktivita. Zelená Bliká: Běží rychlostí 10 Gb/s a vysílá nebo přijímá data. Žlutá Svítí: Běží rychlostí 1 Gb/s, ale žádná aktivita. Žlutá Bliká: Běží rychlostí 1 Gb/s a vysílá nebo přijímá data. Nesvítí: K odpovídajícímu portu není připojeno žádné zařízení.
Zelená svítí: Zařízení pracuje rychlostí 25 Gb/s, ale bez aktivity. Zelená bliká: Zařízení pracuje rychlostí 25 Gb/s a vysílá nebo přijímá data. Žlutá svítí: Zařízení pracuje rychlostí 1 Gb/s/10 Gb/s, ale bez aktivity. Žlutá bliká: Zařízení pracuje rychlostí 1 Gb/s/10 Gb/s a vysílá nebo přijímá data. Nesvítí: K odpovídajícímu portu není připojeno žádné zařízení.

Úvod 07

Omada C.ampus Stackable L3 Managed Switch

LED

Indikace

Port 27-32 of S7500-26XF6Y ***
(Když svítí LED dioda SPD)

Zelená svítí: Zařízení pracuje rychlostí 25 Gb/s, ale bez aktivity. Zelená bliká: Zařízení pracuje rychlostí 25 Gb/s a vysílá nebo přijímá data. Žlutá svítí: Zařízení pracuje rychlostí 1 Gb/s/10 Gb/s, ale bez aktivity. Žlutá bliká: Zařízení pracuje rychlostí 1 Gb/s/10 Gb/s a vysílá nebo přijímá data. Nesvítí: K odpovídajícímu portu není připojeno žádné zařízení.

Port 49-52 of S7500-48XF4C/
Port 25-28 of S7500-24Y4C/ Port 49-56 of S7500-48Y8C/ Port 1-32 of S7500-32C***
(When the SPD/SPEED LED is on)

Zelená Svítí: Běží rychlostí 100 Gb/s, ale žádná aktivita. Zelená Bliká: Běží rychlostí 100 Gb/s a vysílá nebo přijímá data. Žlutá Svítí: Běží rychlostí 40 Gb/s, ale žádná aktivita. Žlutá Bliká: Běží rychlostí 40 Gb/s a vysílá nebo přijímá data. Nesvítí: K odpovídajícímu portu není připojeno žádné zařízení.
Poznámka:
For S7500-48XF4C/S7500-48Y8C/S7500-32C, the indication above applies only when the 100 Gbps QSFP28 slots work with common cables. When the slots work with 1-to-4 breakout cables, a single slot is split into four 25 Gbps interfaces. In such scenario, the LED will light green only when all four interfaces are working at 25 Gbps (maximum speed), otherwise it will light yellow. When no device is connected to any of the four interfaces, the LED will be off. (The 100 Gbps QSFP28 slots will support 1-to-4 breakout cables in a future software release.)

Port 1-32 of S7500-26XF6Y/
Port 1-48 of S7500-48XF4C/ Port 1-28 of S7500-24Y4C/ Port 1-56 of S7500-48Y8C
(Když svítí LED STK)

On: Číslo portu udává ID jednotky v topologii zásobníku.

*By default, S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with a PSM550-AC power supply module installed respectively. One more power supply module needs to be purchased separately. **By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply. ***All 25 Gbps SFP28 slots of S7500-26XF6Y and 100 Gbps QSFP28 slots of S7500-48XF4C/S7500-24Y4C/ S7500-48Y8C/S7500-32C can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Port Introduction (The Management Port, Console Ports, and USB Ports of S7500-48Y8C are located on the rear panel.)
Port pro správu Určen pro připojení zařízení pro správu prostřednictvím web, CLI or SNMP. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. Console Port Designed to connect with a computer for monitoring and configuring the switch. When the switch has an RJ45 console port and a Type-C console port, console input is active on only one console port at a time. By default, the Type-C connector takes priority over the RJ45 connector, or you can change the priority through the web. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. USB Port Designed to install the USB flash disk for data storage. 1000M RJ45 Port Designed to connect to the device with a bandwidth of 10Mbps, 100 Mbps or 1000 Mbps. For PoE switches, the port can also provide power for PDs.

08 Úvod

Omada C.ampus Stackable L3 Managed Switch
2.5G RJ45 Port Designed to connect to the device with a bandwidth of 10 Mbps, 100 Mbps, 1000 Mbps or 2.5 Gbps. For PoE switches, the port can also provide power for PDs. 10G SFP+ Slot Designed to install the 10 Gbps/1 Gbps optical module. 25G SFP28 Slot Designed to install the 25 Gbps/10 Gbps/1 Gbps optical module. 100G QSFP28 Slot Designed to install the 100 Gbps/40 Gbps optical module. Port Feature

Model

1000 mil

2.5G 10G SFP+ 25G SFP28 100G QSFP28 Management Console USB

RJ45 Port RJ45 Port Slot

Slot

Slot

Přístav

Přístav Přístav

S6500-24G4XF

24

/

4

/

/

S6500-48G6XF

48

/

6

/

/

S6500-24GP4XF

24

/

4

/

/

S6500-48GP6XF

48

/

6

/

/

S6500-24M4Y

/

24

/

4

/

S6500-24MPP4Y

/

24

/

4

/

S6500-48M6Y

/

48

/

6

/

S6500-48MPP6Y

/

48

/

6

/

S7500-26XF6Y

/

/

26

6

/

S7500-48XF4C

/

/

48

/

4

S7500-24Y4C

/

/

/

24

4

S7500-48Y8C

/

/

/

48

8

S7500-32C

/

/

/

/

32

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

Rear Panel (The figure is for demonstration only. It may differ from your actual product. )
The rear panel of S6500-24G4XF/S6500-48G6XF is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Kensington Security Slot Grounding Terminal Power Socket

Locking Strap Slot

Poznámka: PWR1 je primární napájecí zdroj a má prioritu před PWR2.

Úvod 09

Omada C.ampus Stackable L3 Managed Switch
The rear panel of S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Bezpečnostní slot Kensington

LED

Uzemňovací svorka

Napájecí modul

LED

Locking Strap Slot

Note: By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, and S650048GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately. Both PWR 1 and PWR2 can work simultaneously, or you can specify the primary power supply and the backup power supply according to your needs. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Uzemňovací svorka

LED

Power Supply Module Locking Strap Slot

LED

Bezpečnostní slot Kensington

Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode: for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply; for S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C, you can specify the primary power supply and the backup power supply according to your needs; Generally, the primary power supply takes priority over the backup power supply.

Zadní panel přepínače S7500-48Y8C je znázorněn na následujícím obrázku. Obrázek slouží pouze pro demonstrační účely. Vzhled vašeho přepínače se může od vyobrazení lišit.

Uzemňovací svorka

LED

LED

Zamykací popruh

Slot

Napájecí modul

10 Úvod

ManagemeC(nTtoyPnposeor-tCle/RPJoU4rt5S)B3P.o0wPeorrSt upplyLoMcokdiSnulgoletStraLpED

Omada C.ampus Stackable L3 Managed Switch
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S7500-32C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

LED dioda LED
Locking Strap Slot
Modul napájecího zdroje Slot pro zabezpečení Kensington

Uzemňovací svorka

LED
Locking Strap Slot

Napájecí modul

Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
Power Supply Module The pluggable power supply module PSM500-AC/PSM900-AC/PSM550-AC is an AC-input power supply module. It can convert the input voltage to 53.5 V (12 V for PSM550-AC) with the maximum output power of 500 W/900 W/550 W respectively. Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Locking Strap Slot Remove the instruction label and insert the AC power cable locking strap into the slot to secure the power cable.

Úvod 11

Omada C.ampus Stackable L3 Managed Switch

Kapitola 2 Instalace

2.1 Obsah balení

Ujistěte se, že balení obsahuje následující položky. Pokud je některá z uvedených položek poškozená nebo chybí, kontaktujte svého distributora. Čísla jsou pouze pro demonstraci. Skutečné položky se mohou lišit vzhledem a množstvím od vyobrazených.

Přepínač

Napájecí kabel a kabel konzoly

Průvodce instalací
Řešení podnikových sítí
Průvodce instalací
Omada C.ampus Stackable L3 Managed Switch

Montážní držáky, šrouby a gumové nožičky

2.2 Bezpečnostní opatření
Abyste předešli jakémukoli poškození zařízení a zraněním způsobeným nesprávným používáním, měli byste dodržovat následující pravidla.
Bezpečnostní opatření Během instalace vypněte napájení. Používejte náramek s ochranou proti elektrostatickému výboji a ujistěte se, že má dobrý kontakt s pokožkou a je
dobře uzemněný. Používejte pouze napájecí kabel dodaný s vypínačem. Ujistěte se, že napájecí napětítage odpovídá specifikacím uvedeným na zadním panelu
přepínač. Ujistěte se, že je spínač instalován v dobře větraném prostředí a jeho ventilační otvor není
zablokováno. Neotevírejte ani neodstraňujte kryt spínače. Před čištěním zařízení vypněte napájení. Nečistěte jej vodou a nikdy
use any other liquid cleaning method. Place the device with its bottom surface facing downwards. Only instructed person or skilled person can be allowed to install, replace, or service this device.
Požadavky na web
Teplota/Vlhkost

12 Instalace

Omada C.ampus Stackable L3 Managed Switch Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the Appendix B Specifications. Clearness
Prach nahromaděný na spínači může být absorbován statickou elektřinou a výsledkem je špatný kontakt kovových kontaktních bodů. Pro zařízení byla přijata určitá opatření, aby se zabránilo statické elektřině, ale příliš silná statická elektřina může způsobit smrtelné poškození elektronických prvků na vnitřní desce s plošnými spoji. Abyste se vyhnuli vlivu statické elektřiny na činnost spínače, přikládejte velký význam následujícím položkám: Pravidelně oprašujte zařízení a udržujte vzduch v místnosti čistý. Udržujte zařízení dobře uzemněné a ujistěte se, že došlo k přenosu statické elektřiny. Elektromagnetické rušení
Elektronické prvky včetně kapacity a indukčnosti na zařízení mohou být ovlivněny vnějšími interferencemi, jako je vedené vyzařování kapacitní vazbou, indukční vazbou a impedanční vazbou. Pro snížení rušení přijměte následující opatření: Použijte napájecí zdroj, který dokáže účinně odfiltrovat rušení ze sítě. Udržujte zařízení daleko od vysokofrekvenčních a silnoproudých zařízení, jako je rádiové vysílání
stanice. V případě potřeby použijte elektromagnetické stínění. Ochrana před bleskem
Instalace 13

Omada C.ampus Stackable L3 Managed Switch
Extrémně vysoké objtagProudy mohou být produkovány okamžitě, když dojde k blesku, a vzduch v dráze elektrického výboje se může okamžitě zahřát až na 20,000 XNUMX °C. Protože tento okamžitý proud je dostatečně silný, aby poškodil elektronická zařízení, měla by být přijata účinnější opatření na ochranu před bleskem. Ujistěte se, že stojan a zařízení jsou dobře uzemněny. Ujistěte se, že zásuvka má dobrý kontakt se zemí. Udržujte přiměřený kabelážní systém a vyhněte se indukovaným bleskům. Při venkovním zapojení použijte signál SPD (Surge Protective Device).
Poznámka: Podrobná opatření k ochraně před bleskem naleznete v Průvodci ochranou před bleskem na adrese: https://support.omadanetworks.com/r/1004/. Místo instalace
When installing the device on a rack or a flat workbench, attach much importance to the following items: Install the device with its bottom surface facing down only. This equipment is not suitable for use in locations where children are likely to be present. The rack or workbench is flat, stable, and sturdy enough to support the weight of 9.5 kg at least. The rack or workbench has a good ventilation system. The equipment room is well ventilated. The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.
2.3 Instalační nástroje
Šroubovák Phillips ESD-preventivní kabel na zápěstí
Poznámka: Tyto nástroje nejsou součástí našeho produktu. V případě potřeby je můžete zakoupit samostatně.
2.4 Instalace produktu
Spínač je navržen s funkcí odvádění tepla zepředu dozadu. Když funguje, vzduch cirkuluje, jak je znázorněno níže. Pro lepší odvod tepla prosím instalujte zařízení v dobře větraném prostředí a ponechte kolem zařízení 5 až 10 cm mezery.
14 Instalace

Obrázek 2-1

Cirkulace vzduchu

Omada C.ampus Stackable L3 Managed Switch

Instalace na plochu

Chcete-li nainstalovat zařízení na plochu, postupujte takto:
1. Umístěte zařízení na rovný povrch, který je dostatečně pevný, aby unesl celou hmotnost zařízení se všemi fitinky.

2. Odstraňte lepicí podložní papíry z gumových nožiček.

3. Připevněte gumové nožičky ke spodní části zařízení, abyste zabránili jeho sklouznutí při umístění na pracovní plochu.

Obrázek 2-2

Instalace na plochu

Nohy Spodní část zářezu zařízení

Instalace do racku

Balení obsahuje 6 páry různých držáků pro montáž do racku, jejich obrázky jsou vyobrazeny níže a mohou se lišit od skutečných produktů.

Obrázek 2-3

Montážní držáky

Skupina otvorů pro šrouby 2

Bracket D Bracket C Bracket B Bracket A

Skupina otvorů pro šrouby 1
Skupina otvorů pro šrouby 3

Závorka F

Screw Hole Group 4-2 (for device with 420mm depth)

Skupina otvorů pro šrouby 5

Šroubová díra

Skupina 4-1

Screw Hole Group 4-3

(for device with 380mm depth)

(for device with

460mm depth)

Držák E

Instalace 15

Omada C.ampus Stackable L3 Managed Switch

Before installing the device in an EIA standard-sized, 19-inch rack, please check the efficiency of the grounding system and the stability of the rack, then wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded. Bracket B, C & E have two adjustable ears, please measure the distance between the front-post rack and the rear-post rack, and determine a suitable mounting method from below:

Metoda

Demonstrace

Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket B (Ear towards back)

Vzdálenost regálu
(For device with a depth of 380mm)

Vzdálenost regálu
(For device with a depth of 420mm)

Vzdálenost regálu
(For device with a depth of 460mm)

498-640mm 538-680mm 578-720mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket C (Ear towards back)

477-498mm 517-538mm 557-578mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards back)

429-477mm 469-517mm 509-557mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards front)

410-429mm 450-469mm 490-509mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 3) + Bracket C (Ear towards back)

357-410mm 397-450mm 437-490mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket B (Ear towards back)

282-410mm 322-450mm 362-490mm

16 Instalace

Omada C.ampus Stackable L3 Managed Switch

Front: Bracket A Rear: Bracket F (Screw Hole Group 4) + Bracket E (Ear towards back)

555-936mm 555-936mm 555-936mm

Front: Bracket A Rear: Bracket F (Screw Hole Group 5) + Bracket E (Ear towards back)

743-1121mm 743-1121mm 743-1121mm

Při instalaci zařízení postupujte podle pokynů popsaných níže:

1. Attach the M6 nuts to the racks.

Obrázek 2-4

Zajištění matic M6

×8

2. Attach the mounting brackets (B, C or E) to the rear-post racks and secure them with the provided M6 screws, as illustrated in the following figure.

Obrázek 2-5

Instalace konzol na stojany

or

3. Attach the brackets A & D/F to the switch with the provided M3 screws.

Instalace 17

Omada C.ampus Stackable L3 Managed Switch

Obrázek 2-6

Instalace držáků na spínač

4. After the brackets are attached to the device, hold the switch with attached brackets up until it aligns with the brackets on the racks, and gently push the switch backwards until it is in place, then secure the device on the racks with M6 screws and fix brackets B/C or E to brackets D or F with M4 screws on both sides.

Obrázek 2-7

Instalace přepínačů do racků

Caution: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Mount devices in the order demonstrated above and ensure a certain clearance between devices for
the purpose of heat dissipation.

18 Instalace

Omada C.ampus Stackable L3 Managed Switch

Instalace napájecího modulu

S6500-24GP4XF is shipped with a PSM500-AC power supply module installed, S6500-48GP6XF/ S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module installed, and S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S750032C is shipped with a PSM550-AC power supply module installed. It looks like below, and the image may differ from your actual product.

Obrázek 2-8

Vzhled modulu napájecího zdroje

Konektor napájecího kabelu
FAN

Přídržné klipy

Rukojeť pro extrakci

LED

Locking Strap Slot Release Handle

Pokud potřebujete přidat ještě jeden napájecí modul, postupujte podle následujících kroků:

1. Noste náramek s ochranou proti elektrostatickým výbojům (ESD) a ujistěte se, že má dobrý kontakt s pokožkou a je dobře uzemněn.

2. Jednou rukou stiskněte vyjímací rukojeť modulu a druhou rukou přidržte spodní část modulu. Jemně zatlačte modul dovnitř podél vodicí lišty slotu.

3. Uvolněte vytahovací rukojeť, abyste zajistili modul napájecího zdroje na místě.

Obrázek 2-9

Instalace modulu napájecího zdroje

Uvolněte rukojeť

Caution: Do not plug the power cord until the power supply module installation is completed. When installing a power supply module, make sure it is set correctly in the operation of installation. Do not use too much force in the installation. If resistance is encountered or positions of the power
supply module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the power supply module is not installed properly. Please check carefully.
The power supply module is designed with a locking strap slot. If you need to secure the power cable with the included locking strap, please follow the steps:
1. Noste náramek s ochranou proti elektrostatickým výbojům (ESD) a ujistěte se, že má dobrý kontakt s pokožkou a je dobře uzemněn.
Instalace 19

Omada C.ampus Stackable L3 Managed Switch
2. Remove the instruction label on the AC power cable locking strap slot. 3. Attach the clamp to the AC power cable and insert the locking strap into the slot. 4. Adjust tightness and distance of the locking strap using clips to ensure the cable is securely fastened.
Figure 2-10 Installing the Locking Strap

Pokud potřebujete vyjmout napájecí modul, postupujte takto:
1. Noste náramek s ochranou proti elektrostatickým výbojům (ESD) a ujistěte se, že má dobrý kontakt s pokožkou a je dobře uzemněn.
2. Depress the retainer clip to release the locking strap, and then remove the power cord from the external power supply system and the power module.
3. Press the extraction handle of the module with one hand, and pull the extraction handle using your other hand, until the module completely comes out of the chassis.
Caution: Unplug the power cord first, then remove the power supply module. When removing a power supply module, make sure that the power supply module is set correctly in the
operation of installation. In order to better protect the power supply module during removal, it is recommended that you
package it in an antistatic bag.
Instalace modulu ventilátoru
S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S650048MPP6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with hot-swappable fan modules installed. They look like below, and the images may differ from your actual product.
Obrázek 2-11 Vzhled modulu ventilátoru
LED

20 Instalace

Extraction Handle Retainer Clips Release Handle

Omada C.ampus Stackable L3 Managed Switch For normal operation of the switch, please ensure that models with 5 fan modules maintain at least 4 operational modules, while models with 4 fan modules maintain at least 3 operational modules. If one fan module is damaged, please replace it as follows: 1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
uzemněn. 2. Jednou rukou stiskněte vytahovací rukojeť modulu a táhněte za ni, dokud
modul se zcela vyjme z šasi.
Obrázek 2-12 Odstranění poškozeného modulu ventilátoru
3. Press the extraction handle of a new fan module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
4. Release the extraction handle to fix the power supply module in place. Caution: S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S6500-48MPP6Y/ S7500-26XF6Y uses hot-swappable fan modules with a maximum speed of 9,000 RPM. S7500-48XF4C/ S7500-24Y4C/S7500-48Y8C/S7500-32C uses hot-swappable fan modules with a maximum speed of 18,000 RPM. Please do not interchange or mix fan modules between models. Sharp edges on the fan module may cause injury, so please operate with caution. Make sure the damaged fan module is in place before you are going to replace it. DO NOT unplug the damaged fan module until the replacement operation. Do not use too much force in the replacement. If resistance is encountered or positions of the fan module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the fan module is not installed properly. Please check carefully.
Instalace 21

Omada C.ampus Stackable L3 Managed Switch

Kapitola 3 Připojení

3.1 Ethernetový port

Připojte ethernetový port přepínače k ​​počítači pomocí kabelu RJ45, jak ukazuje následující obrázek.

Obrázek 3-1

Připojení portu RJ45

Port RJ45

RJ45 Cable

3.2 10G SFP+/25G SFP28/100G QSFP28 Slot

The following figure demonstrates the connection of 10G SFP+/25G SFP28/100G QSFP28 slot to an optical module

Obrázek 3-2

Inserting the Fiber Module

Slot Fiber Module

3.3 Port konzoly
Rozhraní příkazového řádku (CLI) umožňuje spravovat přepínač, takže můžete načíst rozhraní příkazového řádku po připojení počítačů nebo terminálů ke konzolovému portu na přepínači pomocí kabelu (konzolový kabel RJ45 je součástí dodávky, zatímco kabel typu C není součástí dodávky).
Připojte konzolový port RJ45 zařízení k počítači pomocí kabelu konzoly, jak ukazuje následující obrázek.

22 Připojení

Obrázek 3-3

Připojení portu konzoly (RJ45).

Omada C.ampus Stackable L3 Managed Switch

Připojte port konzoly typu C zařízení k počítači pomocí kabelu typu C (není součástí dodávky), jak ukazuje následující obrázek.

Obrázek 3-4

Připojení konzolového (USB) portu

Note: RJ45 console port and Type-C console port cannot be used concurrently. Type-C Console port takes
priority over the RJ45 console port. The Type-C console port is hot-pluggable while the RJ45 console port is not. Keep the device power
off when plugging the console cable into the RJ45 console port. Do not connect the console port with other ports by RJ45 cable.
3.4 Ověřte instalaci
Po dokončení instalace ověřte následující položky: Kolem zařízení by mělo být 5 až 10 cm volného prostoru pro ventilaci a ujistěte se, že proudí vzduch.
je adekvátní. Voltage zdroje splňuje požadavek vstupního objtage zařízení. Zásuvka, zařízení a stojan jsou dobře uzemněny. Zařízení je správně připojeno k jiným síťovým zařízením.
Připojení 23

Omada C.ampus Stackable L3 Managed Switch

3.5 Zapnutí

Zasuňte samičí konektor dodaného napájecího kabelu do napájecí zásuvky zařízení a zasuňte kladný konektor do elektrické zásuvky, jak ukazuje následující obrázek. Ujistěte se, že zvtage zdroje splňuje požadavek vstupního objtage (100-240 V~ 50/60 Hz).

Obrázek 3-5

Připojení ke zdroji napájení

Note: The figure is to illustrate the application and principle. The provided plug and module in your region
may differ from the figures above. Generally PWR1 takes priority over PWR2.

3.6 Inicializace
Po zapnutí zařízení spustí autotest při zapnutí. Automaticky se spustí řada testů, aby byla zajištěna správná funkce zařízení. Během této doby budou jeho LED indikátory reagovat v následujícím pořadí:
1. Indikátor LED PWR svítí stále. Kontrolka SYS a kontrolky LED všech portů nesvítí.
2. Přibližně po jedné minutě LED SYS a LED indikátory všech portů na okamžik zablikají a poté zhasnou.
3. O několik sekund později začne blikat LED kontrolka SYS, což představuje úspěšnou inicializaci.
3.7 Topologie zásobníku
With stackable design, the switches can be stacked into one stack topology for higher reliability, larger bandwidth, and simpler networking. To build the stack topology, you need to prepare 2-12 switches and enough 10G SFP+/25G SFP28/100G QSFP28 modules/cables. For more details, see the table below:

Přepínač

Kompatibilní modely

Množství

S6500-24G4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48G6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24GP4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48GP6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24M4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y S6500-24MPP4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)

24 Připojení

Omada C.ampus Stackable L3 Managed Switch

S6500-48M6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

S6500-48MPP6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

S7500-26XF6Y S7500-26XF6Y

S7500-48XF4C S7500-48XF4C

S7500-24Y4C S7500-24Y4C

S7500-48Y8C S7500-48Y8C

S7500-32C

S7500-32C

2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)

Existují tři struktury topologie zásobníku pro různé scénáře, vytvořte si prosím správnou topologii podle svých potřeb:

1. Řetězová topologie: Řetězová topologie je relativně jednoduchá a nevyžaduje kabelové spojení mezi první a poslední jednotkou. Je vhodný pro dálkové stohování, ale jeho spolehlivost je poměrně nízká.

Obrázek 3-6

Topologie řetězce

Skupina stohovacích portů 2
Skupina stohovacích portů 1

2. Kruhová topologie: Kruhová topologie má vyšší spolehlivost než řetězová topologie. Když je jeden z řetězců v kruhové topologii odpojen, kruhová topologie se stane topologií řetězce, ale celý systém stohu může stále normálně fungovat. Kruhová topologie vyžaduje kabelové propojení mezi první a poslední jednotkou, takže není vhodná pro stohování na velké vzdálenosti.

Obrázek 3-7

Kruhová topologie

Skupina stohovacích portů 2

Skupina stohovacích portů 1

Připojení 25

Omada C.ampus Stackable L3 Managed Switch

3. Hvězdicová topologie: Hvězdicová topologie spojuje přepínače s centrálním hlavním přepínačem, a proto může výrazně zvýšit rychlost předávání dat mezi členskými přepínači a zároveň poskytuje jednotnou správu.

Obrázek 3-8

Topologie hvězd

Skupina stohovacích portů 2

Skupina stohovacích portů 3

Skupina stohovacích portů 1

Note: The stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the
device. Stacking ports with the same group ID are not allowed to connect to stacking ports with different
group IDs, neither to different devices. A stacking port group is a logical port dedicated to stacking and needs to be bound to a stacking port.
A stacking port group can be bound to one or more stacking ports to improve bandwidth and reliability.

26 Připojení

Omada C.ampus Stackable L3 Managed Switch

Kapitola 4 Konfigurace

4.1 Konfigurace přesview
Přepínač podporuje dvě možnosti konfigurace:
Samostatný režim: Konfigurujte a spravujte přepínač samostatně. Režim řadiče: Nakonfigurujte a spravujte síťová zařízení centrálně. Doporučuje se v
rozsáhlá síť, která se skládá z hromadných zařízení, jako jsou přístupové body, přepínače a brány.
Poznámka: Když se přepínač změní ze samostatného režimu na režim ovladače, konfigurace přepínače budou ztraceny. Podrobnosti najdete v souvisejících dokumentech v centru pro stahování našeho oficiálního serveru webweb: https://support.omadanetworks.com/product/.

4.2 Samostatný režim

V samostatném režimu použijte počítač ke konfiguraci a správě přepínače pomocí GUI (Graphical User Interface) nebo CLI (rozhraní příkazového řádku).

Obrázek 4-1

Topologie pro samostatný režim

Přepínač

PC

Pomocí GUI
1. Chcete -li se dostat na stránku správy přepínače, zkontrolujte, zda jsou přepínač a počítač ve stejné podsíti. Otevřete prohlížeč a do pole adresy zadejte IP adresu přepínače a poté stiskněte klávesu Enter.
Pokud přepínač získává IP adresu ze serveru DHCP (obvykle brány), vyhledejte IP adresu přepínače na serveru DHCP.
Pokud ne, použijte výchozí IP adresu 192.168.0.1 ke spuštění stránky správy přepínače.

2. Při prvním přihlášení nastavte uživatelské jméno a heslo pro lepší ochranu vaší sítě a zařízení. Poté vás systém automaticky přesměruje zpět do přihlašovacího rozhraní k ověření pomocí nově vytvořených přihlašovacích údajů.

3. Po úspěšném přihlášení se zobrazí hlavní stránka. Klepnutím na nabídky na horní a levé straně můžete konfigurovat odpovídající funkce.
Podrobné konfigurace naleznete v uživatelské příručce a příručce CLI. Příručky najdete ve středisku pro stahování našeho oficiálního webweb: https://support.omadanetworks.com/product/.
Použití CLI Nastavte připojení Telnet nebo SSH pro přístup k přepínači přes CLI.

Konfigurace 27

Omada C.ampus Stackable L3 Managed Switch

Pro přístup k přepínači použijte port konzoly. Při použití konzolového portu spusťte na PC program emulace terminálu (jako je Hyper Terminal) a nakonfigurujte program emulace terminálu následovně:

Přenosová rychlost 38400 bps

Datové bity 8

Parita Žádná

Stop bity 1

Řízení toku Žádné

Podrobné konfigurace naleznete v uživatelské příručce a příručce CLI. Příručky najdete ve středisku pro stahování našeho oficiálního webweb: https://support.omadanetworks.com/product/.
Note: You may need to change the password the first time you log in, which will better protect your network and devices.

4.3 Režim ovladače
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Pro Hardware Controller (C5300), Omada Pro Software Controller, or Omada Pro Cloud-Based Controller.
Note: Before the following configurations, make sure the switch can access the internet. When using Omada Pro Hardware/Software/Cloud-based Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.

Via Omada Pro Hardware Controller (C5300)

Omada Pro Hardware Controller (C5300) is a good alternative if you have no spare PC to keep running Omada Pro Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Pro Hardware Controller (C5300).

Obrázek 4-2

Manage the network via Omada Pro Hardware Controller (C5300)

Přepínač brány

Omada Pro Hardware Controller (C5300) EAP
28 Konfigurace

EAP

EAP

klienti

Omada C.ampus Stackable L3 Managed Switch

Note: Before you start, be sure to power up and connect your devices according to the topology figure. A DHCP server (typically a gateway with DHCP function enabled) is required to assign IP addresses to
the EAPs and clients in your local network. Omada Pro Controller must have network access to some Omada campus devices (the gateway,
switch, or APs) in order to find, adopt, and manage them.

1. Vyhledejte IP adresu brány. Otevřete příkazový řádek na počítači a zadejte ipconfig. Ve výsledném seznamu vyhledejte Výchozí bránu, což je zároveň IP adresa brány.
2. Spusťte a web prohlížeč a zadejte IP adresu brány. Přihlaste se do prohlížeče web strana. Poté přejděte na Síť > LAN > Seznam klientů DHCP a vyhledejte IP adresu vašeho řadiče podle jeho MAC adresy.
3. Zadejte IP adresu vašeho ovladače do adresního řádku a otevřete jej web strana.
4. Na ovladači Omada Pro web na stránce, postupujte podle průvodce a dokončete rychlé nastavení.
5. Po rychlém nastavení se zobrazí přihlašovací stránka. Zadejte uživatelské jméno a heslo, které jste vytvořili, a klikněte na Přihlásit se. Poté můžete ovladač dále konfigurovat.
6. Pokud chcete zařízení spravovat na dálku, postupujte podle následujících kroků:
A. Ujistěte se, že je na vašem ovladači povolen přístup ke cloudu. Ve výchozím nastavení je Cloud Access povolen. Ujistěte se, že LED dioda Cloud pomalu bliká.

b. Spustit a web prohlížeče a do adresního řádku zadejte https://omada.tplinkcloud.com. Pro přihlášení zadejte své TP-Link ID a heslo. Klikněte na + Přidat ovladač a vyberte Hardware Controller pro přidání ovladače. Poté můžete ovladač dále konfigurovat.

For more details, refer to the Installation Guide of C5300.

Prostřednictvím softwarového ovladače Omada Pro

Download the Omada Pro Software Controller on a PC with Windows OS or Linux OS. Then run the file and follow the wizard to install the Omada Pro Software Controller. Follow the steps below to configure the Controller.

Obrázek 4-3

Spravujte síť pomocí Omada Pro Software Controller

Brána

Přepínač

Ovladač

Omada Pro Software Controller AP

AP

AP

běžící na hostitelském počítači

klienti

Konfigurace 29

Omada C.ampus Stackable L3 Managed Switch

1. Launch the Omada Pro Software Controller on your PC. After the initiation process, the controller automatically opens its web strana. Pokud ne, klikněte na Spustit prohlížeč pro správu sítě.
2. Na ovladači Omada Pro web na stránce, postupujte podle průvodce a dokončete rychlé nastavení.
3. Po rychlém nastavení se zobrazí přihlašovací stránka. Zadejte uživatelské jméno a heslo, které jste vytvořili, a klikněte na Přihlásit se. Poté můžete ovladač dále konfigurovat.
4. Pokud chcete zařízení spravovat na dálku, postupujte podle následujících kroků:
a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Pro Controller’s web přejděte na Nastavení > Přístup ke cloudu, povolte přístup ke cloudu a svažte své ID TP-Link. Pokud jste to nastavili v rychlém nastavení, tento krok přeskočte.
b. Spustit a web prohlížeče a do adresního řádku zadejte https://omada.tplinkcloud.com. Zadejte své TP-Link ID a heslo pro přihlášení. Zobrazí se seznam ovladačů, které byly svázány s vaším TP-Link ID. Poté můžete kliknout na Spustit pro další konfiguraci ovladače.

Note: To manage your devices, Omada Pro Software Controller needs to keep running on your computer.

Prostřednictvím Omada Pro Cloud-Based Controller

Omada Pro Cloud-Based Controller je dobrou alternativou bez nutnosti instalace softwarového ovladače na PC.

Licence je nutné zakoupit dodatečně.

Obrázek 4-4

Spravujte síť pomocí Omada Pro Cloud-Based Controller

Omada Cloud

Brána

Přepínač

AP

AP

AP

AP

klienti
1. Contact the sales staff to grant the Omada Pro Cloud-Based Controller permission. 2. Launch a web prohlížeče a do adresního řádku zadejte https://omada.tplinkcloud.com. Přihlaste se pomocí
your TP-Link ID.
30 Konfigurace

Omada C.ampus Stackable L3 Managed Switch 3. Click + Add Controller and choose Cloud-Based Controller to add an Omada Pro Controller. Then
Můžete spustit ovladač pro přijetí a správu zařízení. * Aplikace Omada Pomocí aplikace Omada můžete také spravovat ovladač na místním nebo vzdáleném místě prostřednictvím mobilního zařízení. Podrobné konfigurace naleznete v uživatelské příručce k ovladači. Průvodce naleznete v centru pro stahování našich oficiálních webweb: https://support.omadanetworks.com/product/.
Konfigurace 31

Omada C.ampus Stackable L3 Managed Switch
Dodatek A Odstraňování problémů
Q1. Co mohu dělat, když jsem zapomněl uživatelské jméno a heslo přepínače?
1. Připojte konzolový port počítače ke konzolovému portu přepínače a spusťte program pro emulaci terminálu.
2. Vypněte a restartujte spínač. Proveďte akci označenou programem emulace terminálu, abyste se dostali do nabídky bootUtil. Akce se liší produkt od produktu. Možné akce jsou uvedeny níže: · Stisknutím libovolné klávesy zastavíte automatické spouštění. · Stisknutím kláves CTRL-B přejděte do nabídky bootUtil.
3. Zobrazí se nabídka bootUtil. Zadejte číslo 6 pro výběr možnosti „Obnovení hesla“ a zadejte Y pro smazání všech uživatelů a hesel. Poté můžete resetovat uživatelské jméno a heslo.
Otázka 2. Proč LED dioda PWR nefunguje normálně? LED dioda PWR/Power by měla svítit, když napájecí systém funguje normálně. Pokud LED dioda PWR/Power nefunguje normálně, postupujte takto:
1. Ujistěte se, že je napájecí kabel správně připojen a že je napájecí kontakt v pořádku. 2. Ujistěte se, že hlasitosttage zdroje splňuje požadavek vstupního objtage z
přepínač.
Q3. Co mám dělat, když nemám přístup k web stránku pro správu? Zkuste následující:
1. Zkontrolujte každý port LED na přepínači a ujistěte se, že je ethernetový kabel správně připojen. 2. Vyzkoušejte jiný port na přepínači a ujistěte se, že ethernetový kabel je vhodný a funguje normálně. 3. Vypněte vypínač a po chvíli jej znovu zapněte. 4. Ujistěte se, že IP adresa vašeho PC je nastavena v podsíti přepínače. 5. Pokud stále nemáte přístup ke konfigurační stránce, resetujte přepínač na výchozí tovární nastavení. Pak
IP adresa vašeho PC by měla být nastavena na 192.168.0.x („x“ je libovolné číslo od 2 do 254) a maska ​​podsítě na 255.255.255.0.
Otázka 4. Proč se program pro emulaci terminálu nezobrazuje správně? Zkuste následující:
1. Ujistěte se, že napájení je normální a kabel konzoly je správně připojen. 2. Zkontrolujte, zda je kabel konzoly správný typ. 3. Ujistěte se, že parametry programu emulace terminálu jsou správné: nakonfigurujte počet bitů za sekundu
jako 38400, datové bity jako 8, parita jako žádná, stop bity jako 1 a řízení toku jako žádné.
32 Příloha A Odstraňování problémů

Omada C.ampus Stackable L3 Managed Switch

Příloha B Specifikace

Specifications for S6500 Series Switches

Položka

Obsah

IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x

Normy

IEEE 802.3af/at (For S6500-24GP4XF, S6500-48GP6XF) IEEE 802.3af/at/bt (For S6500-24MPP4Y, S6500-48MPP6Y)

IEEE 802.3bz, IEEE 802.3by, IEEE 802.3cc (For S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y)

10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) 100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) 2.5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) Transmission Medium 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M)

S6500-24G4XF/S6500-24M4Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-24, Port 25-28 S6500-24GP4XF/S6500-24MPP4Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-24, Port 25-28 LED S6500-48G6XF/S6500-48M6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-48, Port 49-54 S6500-48GP6XF/S6500-48MPP6Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-48, Port 49-54

Dodatek B Specifikace 33

Omada C.ampus Stackable L3 Managed Switch

Rozpočet PoE

For S6500-24GP4XF: 402W (with 1*PSM500-AC, by default) 720W (with 1*PSM900-AC) 720W (with 2*PSM500-AC) 720W (with 1*PSM500-AC and 1*PSM900-AC) 720W (with 2*PSM900-AC) For S6500-48GP6XF: 764W (with 1*PSM900-AC, by default) 384W (with 1*PSM500-AC) 812W (with 2*PSM500-AC) 1176W (with 1*PSM500-AC and 1*PSM900-AC) 1440W (with 2*PSM900-AC) For S6500-24MPP4Y: 751W (with 1*PSM900-AC, by default) 378W (with 1*PSM500-AC) 802W (with 2*PSM500-AC) 1168W (with 1*PSM500-AC and 1*PSM900-AC) 1534W (with 2*PSM900-AC) For S6500-48MPP6Y: 701W (with 1*PSM900-AC, by default) 328W (with 1*PSM500-AC) 752W (with 2*PSM500-AC) 1118W (with 1*PSM500-AC and 1*PSM900-AC) 1484W (with 2*PSM900-AC)

Provozní teplota a nadmořská výška

For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters

Skladovací teplota -40 °C až 70 °C (-40 °F až 158 °F)

Provozní vlhkost 10% až 90% RH Nekondenzující

Skladovací vlhkost

5% až 90% RH Nekondenzující

34 Appendix B Specifications

Omada C.ampus Stackable L3 Managed Switch

Specifications for S7500 Series Switches

Položka

Obsah

Normy

IEEE 802.3, IEEE 802.3x IEEE 802.3z, IEEE 802.3ae (For S7500-26XF6Y, S7500-48XF4C, S7500-24Y4C, S7500-48Y8C IEEE 802.3by, IEEE 802.3cc (For S7500-26XF6Y, S7500-24Y4C, S7500-48Y8C) IEEE 802.3 ba, IEEE 802.3bm (For S7500-48XF4C , S7500-24Y4C, S7500-48Y8C, S7500-32C)

1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M) 40GBASE-SR4/LR4: MMF, SMF (For S7500-48XF4C, S7500-24Y4C, Transmission Medium S7500-48Y8C, S7500-32C) 40G QSFP+ Direct Attach Cable (For S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100GBASE-SR4/LR4: MMF, SMF (SM9110-SR4 for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100G QSFP28 Direct Attach Cable (SM9220-1M for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C)

LED
Provozní teplota a nadmořská výška

S7500-26XF6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP+, SFP28 S7500-48XF4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP+, QSFP28 S7500-24Y4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP28, QSFP28 S7500-48Y8C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP28, QSFP28 S7500-32C: PWR1, PWR2, SYS, MGMT, FAN, MST, SPEED, STK, QSFP28 -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters

Skladovací teplota -40 °C až 70 °C (-40 °F až 158 °F)

Provozní vlhkost 10% až 90% RH Nekondenzující

Skladovací vlhkost

5% až 90% RH Nekondenzující

For S7500-26XF6Y, S7500-48XF4C, and S7500-24Y4C, the maximum operating temperature supported can reach 50 °C (122 °F) @ 300 meters, 45 °C (113 °F) @ 2,000 meters, and 40 °C (104 °F) @ 3,000 meters.
Podporovaná nadmořská výška je od hladiny moře do 5000 m. Je třeba poznamenat, že pokud je nadmořská výška vyšší než 2000 m, pak se maximální provozní teplota sníží o 220 °C (1 °F) na každých 1.8 metrů nárůstu nadmořské výšky.

Dodatek B Specifikace 35

Omada C.ampus Stackable L3 Managed Switch

Specifikace pro napájecí moduly

PSM500-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)

PSM900-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)

PSM550-AC
(For S6500-24M4Y/ S6500-48M6Y/ S7500-26XF6Y/ S7500-48XF4C/ S7500-24Y4C/ S7500-48Y8C/ S7500-32C)

Vstup napájení

100 V­240 V~ 50/60 Hz 8A

100-120V (included)~ 50/60Hz 12A (for locations using low voltage, see specifications for specific countries/ regions)
120 (not included)240V~ 50/60Hz 10A (for other locations)

100 V­240 V~ 50/60 Hz 7A

Výstupní objemtage

Primary: 53.5 VDC Standby: 12 VDC

Primary: 53.5 VDC Standby: 12 VDC

Primary: 12 VDC Standby: 12 VDC

Výstupní proud

9.35 A (maximální)

16.5 A (maximální)

45 A (maximální)

Výstupní výkon

500 W (maximální)

900 W (maximální)

550 W (maximální)

Provozní nadmořská výška

For PSM500-AC/PSM900-AC: Sea level to 3000 m For PSM550-AC: Sea level to 5000 m

36 Appendix B Specifications

Upozornění na značku CE
Jedná se o produkt třídy A. V domácím prostředí může tento produkt způsobovat rádiové rušení, v takovém případě může být uživatel požádán, aby přijal odpovídající opatření.
EU prohlášení o shodě
Společnost TP-Link tímto prohlašuje, že přepínač je v souladu se základními požadavky a dalšími příslušnými ustanoveními směrnic 2014/30/EU, 2014/35/EU, 2011/65/EU a (EU)2015/863. ​​Originál prohlášení o shodě EU naleznete na adrese https://www.tp-link.com/en/support/ce/
Prohlášení o shodě Spojeného království
Společnost TP-Link tímto prohlašuje, že přepínač je v souladu se základními požadavky a dalšími příslušnými ustanoveními předpisů o elektromagnetické kompatibilitě z roku 2016 a předpisů o bezpečnosti elektrických zařízení z roku 2016. Originální prohlášení o shodě pro Spojené království naleznete na adrese https://www.tp-link.com/support/ukca/
, .
POZOR:
Dvoupólové, neutrální jištění. Před servisem odpojte síť.
Bezpečnostní informace
· Udržujte zařízení mimo dosah vody, ohně, vlhkosti nebo horkého prostředí. · Nepokoušejte se zařízení rozebírat, opravovat nebo upravovat. Pokud potřebujete servis, kontaktujte nás. · Umístěte zařízení spodní stranou dolů. · Zástrcka na napájecím kabelu se používá jako odpojovací zaízení, zásuvka musí být
snadno přístupné. · Zapojte výrobek do zásuvky ve zdi s uzemněním pomocí napájecího kabelu
or plug. · The socket-outlet shall be installed near the equipment and shall be easily accessible. · The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium
baterie.

· Operating temperature: For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/ S7500-48XF4C/S7500-24Y4C: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters S7500-48Y8C/S7500-32C: -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
· : S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/ S7500-24Y4C -5°C 50°C23°F 122°F@ 300 -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S7500-48Y8C/S7500-32C -5°C 45°C23°F 113°F@ 300 -5°C 40°C23°F 104°F@ 2,000 -5°C 35°C23°F 95°F@ 3,000
This equipment is not suitable for use in locations
where children are likely to be present.

Při používání zařízení si přečtěte a dodržujte výše uvedené bezpečnostní informace. Nemůžeme zaručit, že nedojde k žádným nehodám nebo škodám v důsledku nesprávného použití zařízení. Používejte prosím tento výrobek opatrně a provozujte jej na vlastní nebezpečí.

Pro technickou podporu, uživatelské příručky a další informace prosím navštivte https://support.omadanetworks.com/ nebo jednoduše naskenujte QR kód.
© 2026 TP-Link 7100002759 REV2.0.1

Dokumenty / zdroje

PDF thumbnailL3 Campus Stackable Managed Switch
User Manual · L3 Campus Stackable Managed Switch, L3, Campus Stackable Managed Switch, Stackable Managed Switch, Managed Switch, Switch

Reference

Zeptejte se

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Zeptejte se

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.