SEEIRIR ET120MPro

SEEIRIR ET120MPro Portable Digital Oscilloscope and Signal Generator

Uživatelská příručka

1. Úvod

The SEEIRIR ET120MPro is a versatile 2-in-1 portable device combining a digital oscilloscope and a signal generator. Designed for electronic maintenance, DIY projects, and automotive diagnostics, it offers a 120MHz bandwidth, 500MS/s sampling rate, and a 3MHz signal source. This manual provides essential information for the safe and effective operation of your device.

2. Bezpečnostní informace

  • Vždy používejte zařízení v rámci jeho specifikovaného objemutage a aktuální limity.
  • Nevystavujte zařízení vlhkosti, extrémním teplotám nebo přímému slunečnímu záření.
  • Do not attempt to disassemble or modify the device. Refer servicing to qualified personnel.
  • Ensure proper grounding when connecting to circuits, especially high-voltage jedničky.
  • Use only the provided or recommended accessories and probes.

3. Konec produktuview

The ET120MPro features a compact design with a clear display and intuitive controls. It integrates a digital oscilloscope for waveform analysis and a signal generator for outputting various test signals.

SEEIRIR ET120MPro Portable Digital Oscilloscope and Signal Generator with display showing a sine wave and signal generation options.

Obrázek 3.1: Přední strana view of the ET120MPro device, showing the display and control buttons. The display illustrates an oscilloscope waveform and menus for Sine, Ramp, and Square signal generation with frequency settings.

3.1. Prvky displeje

  • Zobrazení průběhu: Shows the measured electrical signal.
  • Parametry měření: Displays values like VPP (Peak-to-Peak Voltage), Frequency (F), and other auto-measured data.
  • Časová základna: Indicates the horizontal scale (e.g., 2uS per division).
  • Vertikální citlivost: Indicates the vertical scale (e.g., 500mV per division).
  • Trigger Status: Shows trigger mode (e.g., Auto).
  • Spojka: Indicates AC or DC coupling.
  • Útlum sondy: Shows 1X or 10X setting.

3.2. Ovládací panel

  • JÍDELNÍ LÍSTEK: Přístup do hlavní nabídky pro nastavení.
  • F1/F2: Function buttons, context-sensitive.
  • ULOŽIT: Saves the current waveform data.
  • AC/DC: Toggles between AC and DC coupling for the input signal.
  • 1x/10x: Adjusts probe attenuation setting.
  • 50 %: Sets the trigger level to 50% of the signal amplituda.
  • TRIG: Enters trigger settings menu.
  • MODE/OK: Selects modes or confirms selections.
  • OKRAJ: Volí hranu spouště (nárůstající/klesající).
  • AUTO: Enables auto-ranging for oscilloscope settings.
  • ZASTÁVKA: Stops waveform acquisition.
  • Navigation Arrows (Up/Down/Left/Right): Používá se pro navigaci v menu a nastavení parametrů.

4. Nastavení

4.1. Zapnutí/vypnutí

Press and hold the power button (usually located on the top or side) to turn the device on or off. Ensure the battery is sufficiently charged or connected to a power source.

4.2. Připojení sond

Connect the oscilloscope probe to the input BNC connector. Ensure the probe's ground clip is securely connected to the circuit's ground reference. For signal generation, connect the output cable to the designated signal output port.

4.3. Initial Calibration (if applicable)

Some probes may require compensation. Connect the probe to the calibration output (if available) and adjust the probe's compensation screw until a stable square wave is displayed.

5. Obsluha zařízení

5.1. Režim osciloskopu

The device typically defaults to oscilloscope mode upon startup. If not, navigate through the menu to select it.

  • Automatické měření: Stiskněte tlačítko AUTO button for the device to automatically adjust vertical, horizontal, and trigger settings for a stable waveform display. This also provides automatic readings for frequency, voltage (VPP), and duty cycle.
  • Adjusting Vertical Sensitivity (Volts/Div): Use the navigation arrows to adjust the vertical scale, changing the voltage represented by each vertical division on the grid.
  • Adjusting Time Base (Sec/Div): Use the navigation arrows to adjust the horizontal scale, changing the time represented by each horizontal division.
  • Nastavení spouštění: Stiskněte TRIG to access trigger options. Use OKRAJ to select rising or falling edge triggering. Adjust the trigger level using navigation arrows to stabilize the waveform.
  • Propojení AC/DC: Stiskněte AC/DC to switch between AC coupling (blocks DC component) and DC coupling (shows full signal including DC offset).
  • Útlum sondy: Zajistěte 1X/10X setting on the device matches the physical attenuation setting on your probe.
  • Ukládání průběhů: Stiskněte tlačítko ULOŽIT button to store the current waveform data.

5.2. Režim generátoru signálu

The ET120MPro can generate various waveforms for testing circuits. Access this mode via the main menu or a dedicated function button (if available).

  • Výběr typu vlnového tvaru: Use navigation buttons to choose between Sine, Ramp, and Square waveforms as shown in the product overview obraz.
  • Nastavení frekvence: Adjust the output frequency using the navigation arrows. The device supports frequencies up to 3MHz.
  • Nastavení Amplitude (VPP): Adjust the peak-to-peak voltage of the output signal.

5.3. Správa dat

The device supports USB storage for exporting waveform data. Connect the device to a computer using a USB cable to transfer saved files pro další analýzu.

6. Údržba

  • Čištění: K čištění zařízení používejte měkký, suchý hadřík. Nepoužívejte abrazivní čisticí prostředky ani rozpouštědla.
  • Péče o baterie: Pro optimální výdrž baterie se vyvarujte častého úplného vybíjení baterie. Pokud zařízení delší dobu nepoužíváte, skladujte jej částečně nabité.
  • Skladování: Přístroj skladujte na chladném a suchém místě mimo dosah přímého slunečního záření a extrémních teplot.

7. Řešení problémů

ProblémMožná příčinaŘešení
No display/Device won't power onSlabá baterie; Tlačítko napájení nebylo správně stisknutoNabijte baterii; Stiskněte a pevně podržte tlačítko napájení.
Nestabilní průběhIncorrect trigger settings; Probe compensation issue; Signal too noisyAdjust trigger level/mode; Perform probe compensation; Use AUTO function; Check probe connections.
Není zobrazen žádný signálProbe not connected; Incorrect vertical sensitivity; AC coupling blocking DC signalEnsure probe is connected to circuit; Adjust Volts/Div; Switch to DC coupling.
Signal generator output incorrectNesprávná frekvence/amplitude settings; Output cable issueVerify settings in signal generator mode; Check output cable connection.

8. Specifikace

  • šířka pásma: 120 MHz
  • Sampsazba ling: 500MS / s
  • Digitální kanály: 1
  • Rozlišení displeje: 320*240 pixelů
  • Signal Source Frequency: Až 3 MHz
  • Hmotnost položky: 400 g
  • Rozměry: Přibližně 1 x 1 x 1 cm (rozměry balíku)
  • Výrobce: SEEIRIR
  • Číslo modelu: ET120MPro

9. Záruka a podpora

For warranty information and technical support, please refer to the documentation provided with your purchase or contact SEEIRIR customer service. Keep your proof of purchase for warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.