DATOUBOSS JC-1115

Uživatelská příručka k hybridnímu nepřerušitelnému zdroji napájení DATOUBOSS UPS

Model: JC-1115

Konec produktuview

The DATOUBOSS Hybrid UPS is an integrated power solution designed for off-grid and grid-tied energy storage systems. It combines an Uninterruptible Power Supply (UPS), a solar inverter, and a high-capacity LiFePO4 battery into a single unit, providing reliable backup power and efficient energy management.

This system features an 11kW AC output power and a 15.36kWh LiFePO4 battery with a 51.2V 300Ah capacity, ensuring long-lasting and stable power delivery. It includes dual MPPT solar inputs, each capable of handling up to 5500W, for maximum solar energy harvesting.

DATOUBOSS Hybrid UPS Uninterruptible Power Supply

Obrázek 1: Přední a boční view of the DATOUBOSS Hybrid UPS Uninterruptible Power Supply. The unit is white and grey, featuring a circular display on the front panel and various input/output ports and circuit breakers on the side. It is equipped with casters for mobility.

Bezpečnostní pokyny

  • Před instalací a provozem si přečtěte všechny pokyny.
  • Zajistěte správné uzemnění jednotky.
  • Do not open the unit; there are no user-serviceable parts inside. Refer servicing to qualified personnel.
  • Keep the unit away from water, excessive heat, and direct sunlight.
  • Zajistěte dostatečné větrání kolem jednotky, aby se zabránilo přehřátí.
  • Během instalace a údržby používejte vhodné osobní ochranné prostředky (OOP).

Nastavení

Vybalení a kontrola

Carefully unpack the unit and inspect it for any signs of damage during transit. Report any damage to your supplier immediately.

Umístění

Place the UPS in a cool, dry, and well-ventilated area. Avoid locations with high humidity, dust, or corrosive substances. Ensure sufficient clearance around the unit for airflow.

Spojení

Refer to the connection diagram below for proper wiring. All wiring should be performed by a qualified electrician.

  • Připojení AC vstupu: Connect the main AC power supply to the "AC IN" terminals. Ensure the input voltage matches the unit's specifications (220/230/240VAC).
  • Připojení výstupu střídavého proudu: Connect your loads (appliances, systems) to the "AC OUT" terminals.
  • Připojení FV vstupu: Connect your solar panels to the "PV" input terminals. Observe correct polarity (+/-). The unit supports dual MPPT inputs.
  • Připojení baterie: The LiFePO4 battery is integrated. No external battery connection is required.
  • Základy: Připojte jednotku ke spolehlivému uzemnění.
DATOUBOSS Hybrid UPS Connection Ports

Obrázek 2: Detailní záběr view of the connection ports and circuit breakers on the side of the DATOUBOSS Hybrid UPS. Visible labels include "PV ON/OFF", "AC IN ON/OFF", "INVERTER ON/OFF", "BATTERY ON/OFF", and "AC OUT ON/OFF" for various circuit breakers. Below these are terminals for PV input, AC input, and AC output, along with two AC output sockets.

Návod k obsluze

Zapnutí

  1. Ujistěte se, že všechna připojení jsou bezpečná a správná.
  2. Turn on the "PV ON/OFF" circuit breakers if solar input is desired.
  3. Turn on the "AC IN ON/OFF" circuit breaker to supply grid power to the unit.
  4. Turn on the "INVERTER ON/OFF" switch.
  5. Turn on the "BATTERY ON/OFF" switch.
  6. Finally, turn on the "AC OUT ON/OFF" circuit breakers to supply power to your connected loads.

Displej a indikátory

The front panel features a circular display and indicator lights providing system status.

  • ON/OFF: Indikuje stav napájení jednotky.
  • BĚH: Indicates the system is operating normally.
  • ALM (Alarm): Illuminates when an error or warning condition is detected. Refer to the Troubleshooting section.
  • RESETOVÁNÍ: Button or indicator for system reset.
  • Indikátory stavu baterie: 100%, 75%, 50%, 25% indicate the approximate charge level of the internal battery.
DATOUBOSS Hybrid UPS Front Panel Display

Obrázek 3: Detailní záběr view of the front panel display and indicators on the DATOUBOSS Hybrid UPS. The circular display shows system information, and LED indicators for ON/OFF, RUN, ALM (Alarm), RESET, and battery charge levels (100%, 75%, 50%, 25%) are visible.

Vypnutí

  1. Turn off the "AC OUT ON/OFF" circuit breakers to disconnect loads.
  2. Turn off the "INVERTER ON/OFF" switch.
  3. Turn off the "AC IN ON/OFF" circuit breaker.
  4. Turn off the "PV ON/OFF" circuit breakers.
  5. Finally, turn off the "BATTERY ON/OFF" switch.

Údržba

  • Pravidelný úklid: Keep the unit clean and free of dust. Use a soft, dry cloth to wipe surfaces. Do not use liquid cleaners.
  • Kontrola ventilace: Periodically check that the ventilation openings are not blocked.
  • Kontrola připojení: Každoročně kontrolujte všechny elektrické spoje, zda nejsou těsné a zda nevykazují známky koroze.
  • Údržba baterie: The integrated LiFePO4 battery is designed for long life (10 years) and requires minimal maintenance. Avoid deep discharges where possible to prolong battery life.
  • Skladování: If storing the unit for an extended period, ensure the battery is charged to at least 50% and store in a cool, dry place (0°C to 35°C). Recharge every 3-6 months.

Odstraňování problémů

ProblémMožná příčinaŘešení
Jednotka se nezapne.No AC input; Battery switch off; Internal fault.Check AC input connection and circuit breaker. Ensure "BATTERY ON/OFF" switch is on. If problem persists, contact support.
Žádný AC výstup.AC output breaker tripped; Inverter off; Overload.Check "AC OUT ON/OFF" breaker. Ensure "INVERTER ON/OFF" switch is on. Reduce connected load.
ALM indicator is on.Overload; Over-temperature; Battery fault.Reduce load. Ensure adequate ventilation. If alarm persists, power off and contact support.
Solární nabíjení nefunguje.PV input breaker off; Incorrect PV connection; Insufficient sunlight.Check "PV ON/OFF" breakers. Verify PV panel connections and polarity. Ensure panels are receiving adequate sunlight.

For issues not listed here, or if solutions do not resolve the problem, please contact DATOUBOSS customer support.

Specifikace

ParametrHodnota
Název produktuNepřerušitelný zdroj napájení UPS
Číslo modeluJC-1115
Specifikace11kW/15.36kWh 250A
Kapacita baterie15.36 kWh
Jmenovitý objemtage/Kapacita51.2V 300Ah (LiFePO4)
Výstupní výkon AC11000W
Vstup střídavého proudu220/230/240VAC ±5%, 50Hz/60Hz (adaptive), 150A
AC výstup220/230/240VAC±5%, 50/60Hz ±0.1%, 150A
Maximum Photovoltaic Input Power2*5500W (Total 11000W)
Rozsah sledování MPPT90~500Vdc, 27A
Provozní teplota-10 °C~50 °C
Skladovací teplota0°C~35°C
IP stupeňIP20
Životnost baterie10 years (LiFePO4)
MateriálKov

Záruka a podpora

DATOUBOSS provides a warranty for this product against defects in materials and workmanship under normal use. The specific warranty period may vary by region and purchase agreement. Please retain your proof of purchase for warranty claims.

For technical support, warranty service, or spare parts inquiries, please contact your authorized DATOUBOSS dealer or visit the official DATOUBOSS webstránky pro kontaktní informace.

Note: Information regarding specific warranty duration or availability of spare parts was not provided in the product data. Please refer to your purchase documentation or contact the manufacturer directly for precise details.

© 2025 DATOUBOSS. Všechna práva vyhrazena.

Tato příručka se může změnit bez předchozího upozornění.